Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Proposals for Updated EMC Standards and Requirements (9–500 kHz) for DC Microgrids and New Compliance Verification Methods

View through CrossRef
This paper is aimed at making new proposals for developing future Electro-Magnetic Compatibility (EMC) standards tailored to DC microgrids in a frequency range between 9 and 500 kHz. In particular, new EMC proposals are made to reduce Electro-Magnetic Interference (EMI) with arc hazard detection and narrowband power line communication (PLC). To achieve this, first, arc detection requirements, PLC standards and existing EMC standards are reviewed. Next, new proposals are made to specify EMC requirements for equipment in DC microgrids in terms of conducted emission, immunity (9–500 kHz) and minimum impedance requirement (>40 kHz). The minimum impedance requirement is a new type of requirement and the relevant compliance testing method is developed. The new EMC proposals also distribute frequency bands to support arc detection and narrowband PLC. Then, to show the feasibility and advantage of proposed EMC codes, this paper develops a new arc detection method, which relies on only measuring the arc noise voltage (40–100 kHz) in a single point of the grid and does not need one or more current measurements. A total of three test cases are presented to show the feasibility of the arc detection method and the significance of having an EMC minimum impedance requirement. The executed tests for this paper also show that new EMC proposals are feasible and promising for DC microgrids. This concept and approach are the major novelties of this paper. The specific EMC threshold levels for conducted noise, immunity, and impedance within a frequency range between 9 and 500 kHz will need to be further fine-tuned based on the microgrid application parameters and further gathering of experimental data.
Title: Proposals for Updated EMC Standards and Requirements (9–500 kHz) for DC Microgrids and New Compliance Verification Methods
Description:
This paper is aimed at making new proposals for developing future Electro-Magnetic Compatibility (EMC) standards tailored to DC microgrids in a frequency range between 9 and 500 kHz.
In particular, new EMC proposals are made to reduce Electro-Magnetic Interference (EMI) with arc hazard detection and narrowband power line communication (PLC).
To achieve this, first, arc detection requirements, PLC standards and existing EMC standards are reviewed.
Next, new proposals are made to specify EMC requirements for equipment in DC microgrids in terms of conducted emission, immunity (9–500 kHz) and minimum impedance requirement (>40 kHz).
The minimum impedance requirement is a new type of requirement and the relevant compliance testing method is developed.
The new EMC proposals also distribute frequency bands to support arc detection and narrowband PLC.
Then, to show the feasibility and advantage of proposed EMC codes, this paper develops a new arc detection method, which relies on only measuring the arc noise voltage (40–100 kHz) in a single point of the grid and does not need one or more current measurements.
A total of three test cases are presented to show the feasibility of the arc detection method and the significance of having an EMC minimum impedance requirement.
The executed tests for this paper also show that new EMC proposals are feasible and promising for DC microgrids.
This concept and approach are the major novelties of this paper.
The specific EMC threshold levels for conducted noise, immunity, and impedance within a frequency range between 9 and 500 kHz will need to be further fine-tuned based on the microgrid application parameters and further gathering of experimental data.

Related Results

Epithelial-Myoepithelial Carcinoma of Salivary Glands: A Tertiary Center Experience
Epithelial-Myoepithelial Carcinoma of Salivary Glands: A Tertiary Center Experience
Abstract Introduction Epithelial-myoepithelial carcinoma (EMC) is a rare, biphasic malignant tumor affecting the salivary glands. It represents less than 1% of all salivary gland t...
Molecular Identification of Diabetogenic Viral Gene
Molecular Identification of Diabetogenic Viral Gene
The best evidence that viruses have a causative role in the pathogenesis of insulin-dependent diabetes mellitus comes from experiments in mice infected with encephalomyocarditis (E...
Moderação da classificação ponderal no tracking da pressão arterial elevada em adolescentes
Moderação da classificação ponderal no tracking da pressão arterial elevada em adolescentes
Introdução: Elevadas prevalências de excesso de massa corporal (EMC) e pressão arterial elevada (PAE) têm sido verificadas entre jovens. Ambos os desfechos demonstram tracking sign...
METROLOJİ LABORATORİYALARDA EMC STANDARTLARININ ƏHƏMİYYƏTİ
METROLOJİ LABORATORİYALARDA EMC STANDARTLARININ ƏHƏMİYYƏTİ
Metroloji laboratoriyalarda EMC standartları elektromaqnit təsir prosedurlarını standartlaşdırır ki, sınaqdan sonra alınan keçid sertifikatı qlobal elektronika bazarlarında qəbul e...
Multi-Microgrids Energy Management in Power Transmission Mode with Considering Uncertainties
Multi-Microgrids Energy Management in Power Transmission Mode with Considering Uncertainties
Concepts of microgrids have become a key issue in smart grids today. Increasing the penetration of microgrids in the power grid causes the complexity of power management between th...
Sources of Legal Regulation of Compliance in Ukrainian Banks
Sources of Legal Regulation of Compliance in Ukrainian Banks
Problem setting. The banking sector plays a crucial role in the economy and therefore needs to function in a comprehensive and effective legal environment. In order to monitor comp...
Electrophysical characteristics of nanodimensional cobalte-cuprate-manganite LaNa2CoCuMnO6 and nickelite-cuprate-manganite LaNa2NiCuMnO6
Electrophysical characteristics of nanodimensional cobalte-cuprate-manganite LaNa2CoCuMnO6 and nickelite-cuprate-manganite LaNa2NiCuMnO6
The temperature dependences of the electric capacity, dielectric constant and electrical resistance of cobaltecuprate-manganite of lanthanum and sodium of LaNa2CoCuMnO6 and nickeli...

Back to Top