Javascript must be enabled to continue!
Correction-free force calibration for magnetic tweezers experiments
View through CrossRef
AbstractMagnetic tweezers are a powerful technique to perform high-throughput and high-resolution force spectroscopy experiments at the single-molecule level. The camera-based detection of magnetic tweezers enables the observation of hundreds of magnetic beads in parallel, and therefore the characterization of the mechanochemical behavior of hundreds of nucleic acids and enzymes. However, magnetic tweezers experiments require an accurate force calibration to extract quantitative data, which is limited to low forces if the deleterious effect of the finite camera open shutter time (τsh) is not corrected. Here, we provide a simple method to perform correction-free force calibration for high-throughput magnetic tweezers at low image acquisition frequency (fac). By significantly reducing τsh to at most 1/4 the characteristic time of the tethered magnetic bead, we accurately evaluated the variance of the magnetic bead position along the axis parallel to the magnetic field, estimating the force with a relative error of ~10% (standard deviation), being only limited by the bead-to-bead difference. We calibrated several magnets - magnetic beads configurations, covering a force range from ~50 fN to ~60 pN. In addition, for the presented configurations, we provide a table with the mathematical expressions that describe the force as a function of the magnets position.
Springer Science and Business Media LLC
Title: Correction-free force calibration for magnetic tweezers experiments
Description:
AbstractMagnetic tweezers are a powerful technique to perform high-throughput and high-resolution force spectroscopy experiments at the single-molecule level.
The camera-based detection of magnetic tweezers enables the observation of hundreds of magnetic beads in parallel, and therefore the characterization of the mechanochemical behavior of hundreds of nucleic acids and enzymes.
However, magnetic tweezers experiments require an accurate force calibration to extract quantitative data, which is limited to low forces if the deleterious effect of the finite camera open shutter time (τsh) is not corrected.
Here, we provide a simple method to perform correction-free force calibration for high-throughput magnetic tweezers at low image acquisition frequency (fac).
By significantly reducing τsh to at most 1/4 the characteristic time of the tethered magnetic bead, we accurately evaluated the variance of the magnetic bead position along the axis parallel to the magnetic field, estimating the force with a relative error of ~10% (standard deviation), being only limited by the bead-to-bead difference.
We calibrated several magnets - magnetic beads configurations, covering a force range from ~50 fN to ~60 pN.
In addition, for the presented configurations, we provide a table with the mathematical expressions that describe the force as a function of the magnets position.
Related Results
(Invited) Strategies for Calibration Cost Reduction in Heterogeneous Chemical Sensor Arrays
(Invited) Strategies for Calibration Cost Reduction in Heterogeneous Chemical Sensor Arrays
Introduction
Heterogeneous gas sensor arrays coupled with machine learning algorithms have been proposed for a wide range of applications. However, i...
Analysis of magnetohydrodynamic drag character for hypersonic vehicles
Analysis of magnetohydrodynamic drag character for hypersonic vehicles
In hypersonic flight, a very high temperature area can form ahead of the nose of aerocraft due to the shock aerodynamic heating, which leads to air weakly ionized. Many researchers...
Optical Tweezers
Optical Tweezers
AbstractInfrared lasers focused with high numerical aperture into a microscope are used to exert and measure forces in the piconewton range. Simple light pressure and the more comp...
Magnetic Tweezers
Magnetic Tweezers
Abstract
Magnetic tweezers is a technique that allows applying a constant pulling force and torque on a nucleic acid molecule whi...
Magnetic cloak made of NdFeB permanent magnetic material
Magnetic cloak made of NdFeB permanent magnetic material
In the past few years, the concept of an electromagnetic invisibility cloak has received much attention. Based on the pioneering theoretical work, invisibility cloaks have been gre...
Lysine-selective molecular tweezers are cell penetrant and concentrate in lysosomes
Lysine-selective molecular tweezers are cell penetrant and concentrate in lysosomes
AbstractLysine-selective molecular tweezers are promising drug candidates against proteinopathies, viral infection, and bacterial biofilm. Despite demonstration of their efficacy i...
Radiometric cross-calibration of Sentinel-2B MSI with HY-1C SCS based on the near simultaneous imaging of common ground targets
Radiometric cross-calibration of Sentinel-2B MSI with HY-1C SCS based on the near simultaneous imaging of common ground targets
To simplify the cross-calibration process and improve calibration frequency and accuracy, this paper proposes a cross-calibration method for the multispectral remote sensor Multi-S...
Calibration of Danuri/Wide-Angle Polarimetric Camera (PolCam): Preliminary Results
Calibration of Danuri/Wide-Angle Polarimetric Camera (PolCam): Preliminary Results
The wide-angle polarimetric camera (PolCam) aboard Danuri, South Korea’s first lunar orbiter, represents the first instrument to perform global polarimetric observations of the lun...

