Evaluation of Paravalvular Leakage in Novel Mechanical Heart Valve

View through CrossRef
We developed a new mechanical heart valve prototype with a unique mechanism for attachment to cardiac tissue. The development of novel prosthetic heart valve systems requires careful assessment of paravalvular leaks — leakage of fluid that takes place between the valve and the cardiac tissue it is attached to. Traditional methods of testing paravalvular leaks in flow chambers are not ideal for novel devices and may underestimate its true extent. In this paper we developed a novel method of quantifying paravalvular leaks involving the use of 3D printed prototype heart valves and cadaveric bovine hearts, and compared the results with those from commercially available Medtronic ATS mechanical bileaflet valves. The average leak in our final prototype heart valves were found to be 0.13 ml/sec, compared to 0.33 ml/sec in the ATS valve.
Title: Evaluation of Paravalvular Leakage in Novel Mechanical Heart Valve
Description:
We developed a new mechanical heart valve prototype with a unique mechanism for attachment to cardiac tissue.
The development of novel prosthetic heart valve systems requires careful assessment of paravalvular leaks — leakage of fluid that takes place between the valve and the cardiac tissue it is attached to.
Traditional methods of testing paravalvular leaks in flow chambers are not ideal for novel devices and may underestimate its true extent.
In this paper we developed a novel method of quantifying paravalvular leaks involving the use of 3D printed prototype heart valves and cadaveric bovine hearts, and compared the results with those from commercially available Medtronic ATS mechanical bileaflet valves.
The average leak in our final prototype heart valves were found to be 0.
13 ml/sec, compared to 0.
33 ml/sec in the ATS valve.

Related Results

Multiple Water and Sand Leakage Model Tests for Shield Tunnels
Multiple Water and Sand Leakage Model Tests for Shield Tunnels
Water and sand leakage in shield tunnels has become more of a research interest in recent years. On the other hand, accidents involving underground engineering can take many forms ...
Statistical Characteristics of Flow Field through Open and Semi-Closed Bileaflet Mechanical Heart Valve
Statistical Characteristics of Flow Field through Open and Semi-Closed Bileaflet Mechanical Heart Valve
The formation of thrombi on the streamlined surface of the bileaflet mechanical heart valves is one of the main disadvantages of such valves. Thrombi block the valve leaflets and d...
Branch Barrier Valve for Subsea Application
Branch Barrier Valve for Subsea Application
ABSTRACT A new type subsea repairable pipeline branch barrier valve, invented by TOTAL & STATOIL, has been developed by CAMERON based on the ram type blowout ...
Should bioprostheses be considered the valve of choice for dialysis-dependent patients?
Should bioprostheses be considered the valve of choice for dialysis-dependent patients?
Abstract Background There is controversy regarding the choice of prosthetic valves in patients with cardiac valve disease and dialysis-dependent ...
Simulation Analysis of Flow Characteristics of a Novel Flap Check Valve Based on CFD Method
Simulation Analysis of Flow Characteristics of a Novel Flap Check Valve Based on CFD Method
Abstract The traditional check valves mainly include lift check valves and swing check valves, but the lift check valve has a larger fluid resistance, and the swing ...

Back to Top