Javascript must be enabled to continue!
Initial Torque Stability of a New Bone Condensing Dental Implant. A Cohort Study of 140 Consecutively Placed Implants
View through CrossRef
Abstract
The aim of this paper was to determine the torque resistance of this new implant during placement in different types of bone, immediate placement into sockets, and in grafted bone. The torque at time of placement serves as an indication of initial stability, which is accepted as an important factor for implant osseointegration and immediate loading. Within a 13-month period, 140 NobelActive implants in 84 consecutive patients were placed into types I–IV bone in fresh sockets, and into grafted bone (both in maxillary sinuses and on the facial alveolar surfaces where bone had been lost). The final torque was measured with a manual torque control wrench as manufactured by Nobel Biocare for clinical use with this type of implant. One hundred forty implants with 3.5 to 5 mm diameters and 10 to 15 mm lengths were placed in different types of bone, either as delayed or immediate implants into fresh extraction sockets. These implants demonstrated a mean torque stability value of 50.8 Ncm. The average insertion torque for delayed implants was 49.7 Ncm. For immediate implants the average torque was 52.6 Ncm. Placement into soft bone was also favorable at an average of 47.9 Ncm. Typical straight walled and tapered implants generally exhibit 10 to 35 Ncm insertion torques. The NobelActive implant consistently reaches higher torque levels. This may indicate they are more favorably suited to early provisionalization and loading. Soft bone (type IV) did not seem to decrease significantly the torque of insertion of these implants. Further longer term studies are needed to investigate whether this indeed makes these implants more suited for early provisionalization and loading than traditional root form. Long term studies are also needed to investigate maintenance of bone levels surrounding these implants.
Title: Initial Torque Stability of a New Bone Condensing Dental Implant. A Cohort Study of 140 Consecutively Placed Implants
Description:
Abstract
The aim of this paper was to determine the torque resistance of this new implant during placement in different types of bone, immediate placement into sockets, and in grafted bone.
The torque at time of placement serves as an indication of initial stability, which is accepted as an important factor for implant osseointegration and immediate loading.
Within a 13-month period, 140 NobelActive implants in 84 consecutive patients were placed into types I–IV bone in fresh sockets, and into grafted bone (both in maxillary sinuses and on the facial alveolar surfaces where bone had been lost).
The final torque was measured with a manual torque control wrench as manufactured by Nobel Biocare for clinical use with this type of implant.
One hundred forty implants with 3.
5 to 5 mm diameters and 10 to 15 mm lengths were placed in different types of bone, either as delayed or immediate implants into fresh extraction sockets.
These implants demonstrated a mean torque stability value of 50.
8 Ncm.
The average insertion torque for delayed implants was 49.
7 Ncm.
For immediate implants the average torque was 52.
6 Ncm.
Placement into soft bone was also favorable at an average of 47.
9 Ncm.
Typical straight walled and tapered implants generally exhibit 10 to 35 Ncm insertion torques.
The NobelActive implant consistently reaches higher torque levels.
This may indicate they are more favorably suited to early provisionalization and loading.
Soft bone (type IV) did not seem to decrease significantly the torque of insertion of these implants.
Further longer term studies are needed to investigate whether this indeed makes these implants more suited for early provisionalization and loading than traditional root form.
Long term studies are also needed to investigate maintenance of bone levels surrounding these implants.
Related Results
Frequency of Common Chromosomal Abnormalities in Patients with Idiopathic Acquired Aplastic Anemia
Frequency of Common Chromosomal Abnormalities in Patients with Idiopathic Acquired Aplastic Anemia
Objective: To determine the frequency of common chromosomal aberrations in local population idiopathic determine the frequency of common chromosomal aberrations in local population...
Awareness of Dental Personnel towards Occupational Injury- A Cross Sectional Study
Awareness of Dental Personnel towards Occupational Injury- A Cross Sectional Study
TITLE:
Awareness of dental personnel towards occupational injury- a cross sectional study
ABSTRACT
Objective: To determine the awareness of dental personnel towards dental occup...
Patterns of Treatment Modalities in Saudi Patients Treated with Dental Implants
Patterns of Treatment Modalities in Saudi Patients Treated with Dental Implants
Aim: The primary aim of this study was to detect the patterns of implant prosthetic treatment modalities among Saudi adults restored with dental implants in the Kingdom of Saudi Ar...
Soft tissue reconstructive techniques at implant sites
Soft tissue reconstructive techniques at implant sites
Dental implants have shown to be a reliable tool for single, multiple and full-arch rehabilitations 1. Dental implants have a very high success rate in terms of osseointegration, h...
Comparative Clinical Study of Conventional Dental Implants and Mini Dental Implants for Mandibular Overdentures: A Randomized Clinical Trial
Comparative Clinical Study of Conventional Dental Implants and Mini Dental Implants for Mandibular Overdentures: A Randomized Clinical Trial
AbstractBackgroundDental implant‐retained overdentures have been chosen as the treatment of choice for complete mandibular removable dentures. Dental implants, such as mini dental ...
Dental Implants’ Primary and Secondary Stability Assessment according to Implant Macro-Design, Length and Width, Location, and Bone Quality.
Dental Implants’ Primary and Secondary Stability Assessment according to Implant Macro-Design, Length and Width, Location, and Bone Quality.
Some evidence supports the influence of the implant macro-design and primary stability. Additionally, tactile perception can be used to assess implant stability when placing the im...
Primary and Secondary Stability Assessments of Dental Implants According to Their Macro-Design, Length, Width, Location, and Bone Quality
Primary and Secondary Stability Assessments of Dental Implants According to Their Macro-Design, Length, Width, Location, and Bone Quality
Some evidence supports the influence of implant macro-design on primary stability. Additionally, tactile perception can be used to assess implant stability when placing the implant...
Knowledge, Awareness & Attitude regarding Dental Implants among Dental Interns in Central Vidarbha
Knowledge, Awareness & Attitude regarding Dental Implants among Dental Interns in Central Vidarbha
BACKGROUND Implant therapy is an elective dental procedure of dental rehabilitative treatment. The aim of this study was to assess the knowledge, awareness, and attitude of dental ...