Javascript must be enabled to continue!
Study on Fault Analysis and early warning system of wind-induced disasters on transmission lines
View through CrossRef
Wind-induced disaster has become one of the most important disasters affecting the safe operation of power grid. In order to improve the effect of prevention and treatment of wind-induced disasters, it is very important to give early warning and real-time warning. Therefore, based on the climate characteristics of Shandong power grid, this paper presents the wind speed statistical law and the distribution characteristics of the number of days with strong wind. By analysing the mechanism of wind-induced disasters and combining the fault data of five years, the characteristics and rules of wind deviation and foreign short-circuit fault are obtained. On this basis, an early warning model of wind deviation based on the calibration of minimum air gap and the determination of maximum wind speed is established. At the same time, there is a short circuit model based on visual image information. Based on GeoServer platform, we will develop an early warning system for wind-induced disasters of transmission lines, which can provide real-time warning and early warning for wind-induced disasters. The application of the system can reduce the impact of wind damage on the transmission line, and effectively improve the operation reliability of the line.
Title: Study on Fault Analysis and early warning system of wind-induced disasters on transmission lines
Description:
Wind-induced disaster has become one of the most important disasters affecting the safe operation of power grid.
In order to improve the effect of prevention and treatment of wind-induced disasters, it is very important to give early warning and real-time warning.
Therefore, based on the climate characteristics of Shandong power grid, this paper presents the wind speed statistical law and the distribution characteristics of the number of days with strong wind.
By analysing the mechanism of wind-induced disasters and combining the fault data of five years, the characteristics and rules of wind deviation and foreign short-circuit fault are obtained.
On this basis, an early warning model of wind deviation based on the calibration of minimum air gap and the determination of maximum wind speed is established.
At the same time, there is a short circuit model based on visual image information.
Based on GeoServer platform, we will develop an early warning system for wind-induced disasters of transmission lines, which can provide real-time warning and early warning for wind-induced disasters.
The application of the system can reduce the impact of wind damage on the transmission line, and effectively improve the operation reliability of the line.
Related Results
Integration Techniques of Fault Detection and Isolation Using Interval Observers
Integration Techniques of Fault Detection and Isolation Using Interval Observers
An interval observer has been illustrated to be a suitable approach to detect and isolate faults affecting complex dynamical industrial systems.
Concerning fault detection, interv...
Decomposition and Evolution of Intracontinental Strike‐Slip Faults in Eastern Tibetan Plateau
Decomposition and Evolution of Intracontinental Strike‐Slip Faults in Eastern Tibetan Plateau
Abstract:Little attention had been paid to the intracontinental strike‐slip faults of the Tibetan Plateau. Since the discovery of the Longriba fault using re‐measured GPS data in 2...
Analysis of Senegal Type Vertical Axis Wind Turbines Arrangement in Wind Farm
Analysis of Senegal Type Vertical Axis Wind Turbines Arrangement in Wind Farm
Background:
In a wind farm, the wind speed of the downstream wind turbine will be
lower than the wind speed of the upstream wind turbine due to the influence of the wake. Therefore...
Structural Characteristics and Evolution Mechanism of Paleogene Faults in the Central Dongying Depression, Bohai Bay Basin
Structural Characteristics and Evolution Mechanism of Paleogene Faults in the Central Dongying Depression, Bohai Bay Basin
Abstract
This study used the growth index, fault activity rate and fault distance burial depth curve methods to analyze the characteristics of fault activity in the central...
Data-driven Fault Diagnosis for Cyber-Physical Systems
Data-driven Fault Diagnosis for Cyber-Physical Systems
The concept of Industry 4.0 uses cyber-physical systems and the Internet of Things to create "smart factories" that enable automated and connected production. However, the complex ...
Savonius Rotor for Offshore Wind Energy Conversion
Savonius Rotor for Offshore Wind Energy Conversion
Abstract
Analysis of performance is presented for wind energy conversion by a Savonius type vertical axis rotor configured for generation of electrical power. The...
Performance Test and Simulation Study on the Air Path of CAP1400 Passive Containment Cooling System
Performance Test and Simulation Study on the Air Path of CAP1400 Passive Containment Cooling System
As a large scale passive pressurized water reactor nuclear power plant, CAP1400 can remove the reactor decay heat to outside containment with the air cooling in the air flow path o...
Low-temperature thermochronology of fault zones
Low-temperature thermochronology of fault zones
<p>Thermal signatures as well as timing of fault motions can be constrained by thermochronological analyses of fault-zone rocks (e.g., Tagami, 2012, 2019).&#1...