Javascript must be enabled to continue!
Simulasi Sistem Transfer Daya Nirkabel Berbasis Kopling Magnetik
View through CrossRef
Technological developments require the development of wireless power transfer systems. From the various types of technology, magnetic coupling-based wireless power transfer system is one of the most widely used technologies. This research was conducted to study and design a magnetic coupling based wireless power transfer system circuit using the Proteus 8 simulation software. This wireless power transfer system consists of a transceiver, an inductive coil, and a power receiver. Experiments have been carried out and a wireless power transfer system using inductive coupling can produce power readings in the receiver coil circuit. The measured voltage value on the receiver coil in real (not ideal) conditions indicates power losses of at least 17.1296% due to electromagnetic interference. However, this magnetic coupling based wireless power transfer system can provide charging flexibility so that it remains attractive for application in various technologies.
Indonesian Society of Applied Science (ISAS)
Title: Simulasi Sistem Transfer Daya Nirkabel Berbasis Kopling Magnetik
Description:
Technological developments require the development of wireless power transfer systems.
From the various types of technology, magnetic coupling-based wireless power transfer system is one of the most widely used technologies.
This research was conducted to study and design a magnetic coupling based wireless power transfer system circuit using the Proteus 8 simulation software.
This wireless power transfer system consists of a transceiver, an inductive coil, and a power receiver.
Experiments have been carried out and a wireless power transfer system using inductive coupling can produce power readings in the receiver coil circuit.
The measured voltage value on the receiver coil in real (not ideal) conditions indicates power losses of at least 17.
1296% due to electromagnetic interference.
However, this magnetic coupling based wireless power transfer system can provide charging flexibility so that it remains attractive for application in various technologies.
Related Results
Perawatan dan Perbaikan Sistem Kopling Manual Beberapa Jenis Mobil Operasional PT. Delta Sarana Sentosa
Perawatan dan Perbaikan Sistem Kopling Manual Beberapa Jenis Mobil Operasional PT. Delta Sarana Sentosa
Pembuatan komponen-komponen kopling dari pabrik mempunyai perkiraan atau batas pemakaian komponen kopling yang harus diganti apabila ada kerusakan yang terjadi. Tujuan dari pengama...
Penentuan Kandungan Logam Magnetik Komponen Penyusun Abu Layang Batubara
Penentuan Kandungan Logam Magnetik Komponen Penyusun Abu Layang Batubara
Telah dilakukan penelitian penentuan kandungan logam magnetik penyusun abu layang batubara. Abu layang merupakan material berupa serbuk halus yang dihasilkan dari pembakaran batuba...
Identifikasi Reservoir Panas Bumi Berdasarkan Pemodelan 2D Anomali Magnetik
Identifikasi Reservoir Panas Bumi Berdasarkan Pemodelan 2D Anomali Magnetik
Penelitian mengenai identifikasi reservoar panas bumi telah dilakukan di kompleks gunung Pandan Jawa Timur menggunakan metode magnetik. Penelitian ini bertujuan untuk mengetahui ke...
<b>Analisis Pengaruh Variasi Sudut Kopling Terhadap Kinerja Turbin Angin Savonius <i>Single Stage</i> Menggunakan Metode CFD</b>
<b>Analisis Pengaruh Variasi Sudut Kopling Terhadap Kinerja Turbin Angin Savonius <i>Single Stage</i> Menggunakan Metode CFD</b>
Turbin angin Savonius merupakan salah satu turbin angin sumbu vertikal yang memiliki keunggulan dalam kemampuan beroperasi secara mandiri (self-starting) pada kondisi kecepatan ang...
Analisa Sistem Kelistrikan Gedung RSUD Arifin Achmad Pekanbaru
Analisa Sistem Kelistrikan Gedung RSUD Arifin Achmad Pekanbaru
Kapasitas daya listrik di Gedung Rumah Sakit Umum Daerah Arifin Achmad PLN ada tiga yaitu dengan ID No. 181101059392 dengan daya semu 1.730 kVA, daya aktif 1.384 kW, daya reakt...
SIMULASI ALIRAN DAYA PADA SISTEM TENAGA LISTRIK DI GARDU INDUK GANDUL PT. PLN (PERSERO) MENGGUNAKAN SOFTWARE MATLAB POWER SYSTEM ANALYSIS TOOLBOX (PSAT) 2.1.7 DENGAN METODE NEWTON RAPHSON
SIMULASI ALIRAN DAYA PADA SISTEM TENAGA LISTRIK DI GARDU INDUK GANDUL PT. PLN (PERSERO) MENGGUNAKAN SOFTWARE MATLAB POWER SYSTEM ANALYSIS TOOLBOX (PSAT) 2.1.7 DENGAN METODE NEWTON RAPHSON
ABSTRACT
This study aims to determine the results of the simulation of the power flow transformer 4 10 buses in the Gandul Substation of PT. PLN (Persero) with MATLAB Power S...
Manajemen Hotspot Mikrotik Menggunakan Freeradius dan Sistem Monitoring
Manajemen Hotspot Mikrotik Menggunakan Freeradius dan Sistem Monitoring
Kantor ataupun instansi yang menggunakan jaringan nirkabel atau hotspot dengan banyak pengguna memerlukan manajemen pengguna. Penerapan manajemen pengguna ini bertujuan untuk mempe...
PEMBUATAN TRAINER CUTING KOPLING HIDRAULIS MOBIL TOYOTA KIJANG KF 40
PEMBUATAN TRAINER CUTING KOPLING HIDRAULIS MOBIL TOYOTA KIJANG KF 40
Untuk memberikan suasana nyaman dalam perputaran mesin, perlu dipasang suatu komponen yaitu Kopling.Kopling berdasarkan mekanismenya di bedakan menjadi 2 jenis yaitu kopling mekani...

