Javascript must be enabled to continue!
Underwater Radiance Distributions Measured with Miniaturized Multispectral Radiance Cameras
View through CrossRef
AbstractMiniaturized radiance cameras measuring underwater multispectral radiances in all directions at high-radiometric accuracy (CE600) are presented. The camera design is described, as well as the main steps of its optical and radiometric characterization and calibration. The results show the excellent optical quality of the specifically designed fish-eye objective. They also show the low noise and excellent linearity of the complementary metal oxide semiconductor (CMOS) detector array that is used. Initial results obtained in various oceanic environments demonstrate the potential of this instrument to provide new measurements of the underwater radiance distribution from the sea surface to dimly lit layers at depth. Excellent agreement is obtained between nadir radiances measured with the camera and commercial radiometers. Comparison of the upwelling radiance distributions measured with the CE600 and those obtained with another radiance camera also shows a very close agreement. The CE600 measurements allow all apparent optical properties (AOPs) to be determined from integration of the radiance distributions and inherent optical properties (IOPs) to be determined from inversion of the AOPs. This possibility represents a significant advance for marine optics by tying all optical properties to the radiometric standard and avoiding the deployment of complex instrument packages to collect AOPs and IOPs simultaneously (except when it comes to partitioning IOPs into their component parts).
Title: Underwater Radiance Distributions Measured with Miniaturized Multispectral Radiance Cameras
Description:
AbstractMiniaturized radiance cameras measuring underwater multispectral radiances in all directions at high-radiometric accuracy (CE600) are presented.
The camera design is described, as well as the main steps of its optical and radiometric characterization and calibration.
The results show the excellent optical quality of the specifically designed fish-eye objective.
They also show the low noise and excellent linearity of the complementary metal oxide semiconductor (CMOS) detector array that is used.
Initial results obtained in various oceanic environments demonstrate the potential of this instrument to provide new measurements of the underwater radiance distribution from the sea surface to dimly lit layers at depth.
Excellent agreement is obtained between nadir radiances measured with the camera and commercial radiometers.
Comparison of the upwelling radiance distributions measured with the CE600 and those obtained with another radiance camera also shows a very close agreement.
The CE600 measurements allow all apparent optical properties (AOPs) to be determined from integration of the radiance distributions and inherent optical properties (IOPs) to be determined from inversion of the AOPs.
This possibility represents a significant advance for marine optics by tying all optical properties to the radiometric standard and avoiding the deployment of complex instrument packages to collect AOPs and IOPs simultaneously (except when it comes to partitioning IOPs into their component parts).
Related Results
Emerging underwater survey technologies: A review and future outlook
Emerging underwater survey technologies: A review and future outlook
Emerging underwater survey technologies are revolutionizing the way we explore and understand the underwater world. This review examines the latest advancements in underwater surve...
Edge Enhanced CrackNet for Underwater Crack Detection of Concrete Dams
Edge Enhanced CrackNet for Underwater Crack Detection of Concrete Dams
Underwater crack detection in dam structures is of significant engineering importance and scientific value for ensuring the structural safety, assessing operational conditions, and...
Optimizing Underwater Vision: A Rigorous Investigation into CNN's Deep Image Enhancement for Subaquatic Scenes
Optimizing Underwater Vision: A Rigorous Investigation into CNN's Deep Image Enhancement for Subaquatic Scenes
In this paper, Convolutional Neural Networks were used to enhance the visual fidelity of underwater images. The UWCNN is introduced in this article, which utilizes underwater scene...
Underwater Image Enhancement using GAN
Underwater Image Enhancement using GAN
The process of enhancing the distorted underwater images to clear image is known as Underwater image enhance- ment. Distorted images are the raw underwater images that taken from t...
Underwater Pile Driving Test Offshore Louisiana
Underwater Pile Driving Test Offshore Louisiana
ABSTRACT
This report presents results of an underwater pile driving test conducted at South Marsh Island Block 130, offshore Louisiana. A 24inch diameter tubular ...
Influences on flood frequency distributions in Irish river catchments
Influences on flood frequency distributions in Irish river catchments
Abstract. This study explores influences which result in shifts of flood frequency distributions in Irish rivers. Generalised Extreme Value (GEV) type I distributions are recommend...
Global Calibration of Multi-Cameras Based on Refractive Projection and Ray Tracing
Global Calibration of Multi-Cameras Based on Refractive Projection and Ray Tracing
Multi-cameras system is widely applied in 3D computer vision especially when multiple cameras are distributed on both sides of the measured object. The calibration methods of multi...
Bands Selection for Multispectral Detection Mode of Lunar Mineralogical Spectrometer of China’s Chang’E-5 and Chang’E-6 Missions
Bands Selection for Multispectral Detection Mode of Lunar Mineralogical Spectrometer of China’s Chang’E-5 and Chang’E-6 Missions
Introduction:  In December 2020, China’s Chang’E-5 (CE-5) mission successfully landed in the northeastern part of Oceanus Procellarum on the Moon and a...

