Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Can Syndesmosis Screws Displace the Distal Fibula?

View through CrossRef
Background. There has been historical debate as to whether the distal tibiofibular syndesmosis can be overtightened during operative fixation. We used finite-element analysis to determine if overtightening of syndesmotic screws can cause widening of the lateral gutter clear space in the ankle joint. Methods. A 3D finite-element model was constructed and analyzed using geometries from a computed tomography scan of a cadaveric lower leg. Starting 2 cm from the plafond, screw fixation was simulated at 5-mm increments to a distance of 5 cm from the plafond. The fibula was compressed 2 mm toward the tibia at each interval, and the change in distance between the lateral talus and distal fibula was measured. Results. Medial deflection of the fibula resulted in widening of the lateral clear space, which was proportional to the amount of deflection. The effect increased as screws were placed closer to the plafond, with 1.5 mm of widening at 2 cm (0.76 mm/mm) versus 0.7 mm at 5 cm (0.34 mm/mm). Conclusion. Our finite-element model demonstrated that overtightening of the distal tibiofibular syndesmosis with medial fibular displacement can cause widening of the lateral clear space. Clinical relevance. The results suggest that screws placed farther from the plafond widen the lateral clear space to a lesser degree, which may be advantageous during surgical fixation to prevent clear space widening and increased tibiotalar contact forces. Levels of Evidence: Level I
Title: Can Syndesmosis Screws Displace the Distal Fibula?
Description:
Background.
There has been historical debate as to whether the distal tibiofibular syndesmosis can be overtightened during operative fixation.
We used finite-element analysis to determine if overtightening of syndesmotic screws can cause widening of the lateral gutter clear space in the ankle joint.
Methods.
A 3D finite-element model was constructed and analyzed using geometries from a computed tomography scan of a cadaveric lower leg.
Starting 2 cm from the plafond, screw fixation was simulated at 5-mm increments to a distance of 5 cm from the plafond.
The fibula was compressed 2 mm toward the tibia at each interval, and the change in distance between the lateral talus and distal fibula was measured.
Results.
Medial deflection of the fibula resulted in widening of the lateral clear space, which was proportional to the amount of deflection.
The effect increased as screws were placed closer to the plafond, with 1.
5 mm of widening at 2 cm (0.
76 mm/mm) versus 0.
7 mm at 5 cm (0.
34 mm/mm).
Conclusion.
Our finite-element model demonstrated that overtightening of the distal tibiofibular syndesmosis with medial fibular displacement can cause widening of the lateral clear space.
Clinical relevance.
The results suggest that screws placed farther from the plafond widen the lateral clear space to a lesser degree, which may be advantageous during surgical fixation to prevent clear space widening and increased tibiotalar contact forces.
Levels of Evidence: Level I.

Related Results

Syndesmosis Instability
Syndesmosis Instability
The syndesmosis is one of important stabilizer of the ankle joint and consists of a complex ligamentous structure: the anterior inferior tibiofibular ligament; the interosseous lig...
Revision Ankle Syndesmosis Fixation: Functional Outcome after TightRope® Fixation
Revision Ankle Syndesmosis Fixation: Functional Outcome after TightRope® Fixation
ABSTRACT Introduction Syndesmotic injuries present a challenge to orthopedic surgeons. Malreduction of the syndesmosis has been reported to cause instability and secondary osteoar...
Pullout strength of monocortical and bicortical screws in meta -physeal and diaphyseal regions of the canine humerus
Pullout strength of monocortical and bicortical screws in meta -physeal and diaphyseal regions of the canine humerus
Summary Objective: Monocortical screws are commonly employed in locking plate fixation, but specific recommendations for their placement are lacking and use of short mono...
Revision of Syndesmosis Screw Fixation
Revision of Syndesmosis Screw Fixation
Background: Many syndesmosis screw fixations do not achieve success at the first attempt. Currently, there are no data available to evaluate revision of syndesmosis screw failure. ...
MRI analysis of distal tibiofibular joint and ankle anatomy to assess lateral ankle sprain risk
MRI analysis of distal tibiofibular joint and ankle anatomy to assess lateral ankle sprain risk
Abstract Objective To evaluate the risk of lateral ankle sprain (LAS) related to bone anatomical variations of the distal tibiofibular syndesmosi...
Stiffness Comparisons of SOP Interlocking Plate Configurations in 3D Printed Canine Lumbosacral Vertebrae
Stiffness Comparisons of SOP Interlocking Plate Configurations in 3D Printed Canine Lumbosacral Vertebrae
There are no published biomechanical studies evaluating the effect of stabilization techniques on the stability of the 3D printed models of the canine lumbosacral junction. The p...

Back to Top