Javascript must be enabled to continue!
Transient vacuolar changes of the crystalline lens in patients using a dispersive ophthalmic viscosurgical device
View through CrossRef
AIM: To report the clinical prognosis and pathological findings of accidental lens vacuolar changes in eyes with intraoperative exposure to a dispersive ophthalmic viscosurgical device (OVD).
METHODS: Two patients who developed transient lens vacuolar changes during uneventful persistent pupillary membrane (PPM) removal surgery were presented and followed up. This event was speculated to be associated with an intraoperative dispersive OVD DisCoVisc (hyaluronic acid 1.6%-chondroitin sulfate 4.0%) exposure. Then, to provide the pathological basis for our speculation, another four cataract patients were randomly exposed to different OVDs, and their anterior lens capsules were investigated with transmission electron microscopy (TEM).
RESULTS: After months, the subcapsular vacuoles in both PPM cases were gradually disappeared without visual deterioration. For the cataract patients, similar lens changes were observed intraoperatively in those exposed to a dispersive DisCoVisc but not a cohesive OVD IVIZ (sodium hyaluronate gel 1.0%). In addition, marked ultrastructural changes, including chromatin condensation, extensive cytoplasmic vacuoles, and obvious intercellular space between lens epithelial cells in the anterior lens capsules of all eyes exposed to DisCoVisc, were observed by TEM.
CONCLUSION: The lens vacuolar changes may be associated with a dispersive OVD exposure. Therefore, it is not preferable to use dispersive OVDs in patients with transparent lenses or without the intention of lens extraction. In addition, close follow-ups instead of immediate lens extraction are recommended for the occurrence of similar lens lesions.
Press of International Journal of Ophthalmology (IJO Press)
Title: Transient vacuolar changes of the crystalline lens in patients using a dispersive ophthalmic viscosurgical device
Description:
AIM: To report the clinical prognosis and pathological findings of accidental lens vacuolar changes in eyes with intraoperative exposure to a dispersive ophthalmic viscosurgical device (OVD).
METHODS: Two patients who developed transient lens vacuolar changes during uneventful persistent pupillary membrane (PPM) removal surgery were presented and followed up.
This event was speculated to be associated with an intraoperative dispersive OVD DisCoVisc (hyaluronic acid 1.
6%-chondroitin sulfate 4.
0%) exposure.
Then, to provide the pathological basis for our speculation, another four cataract patients were randomly exposed to different OVDs, and their anterior lens capsules were investigated with transmission electron microscopy (TEM).
RESULTS: After months, the subcapsular vacuoles in both PPM cases were gradually disappeared without visual deterioration.
For the cataract patients, similar lens changes were observed intraoperatively in those exposed to a dispersive DisCoVisc but not a cohesive OVD IVIZ (sodium hyaluronate gel 1.
0%).
In addition, marked ultrastructural changes, including chromatin condensation, extensive cytoplasmic vacuoles, and obvious intercellular space between lens epithelial cells in the anterior lens capsules of all eyes exposed to DisCoVisc, were observed by TEM.
CONCLUSION: The lens vacuolar changes may be associated with a dispersive OVD exposure.
Therefore, it is not preferable to use dispersive OVDs in patients with transparent lenses or without the intention of lens extraction.
In addition, close follow-ups instead of immediate lens extraction are recommended for the occurrence of similar lens lesions.
Related Results
Pupillary Membrane Persistence in a Feline
Pupillary Membrane Persistence in a Feline
Background:Pupillary membrane persistence (PMP) is a congenital abnormality, which is not usually reported in felines. It is characterized by remnants of the fetal membrane that pe...
Autonomy on Trial
Autonomy on Trial
Photo by CHUTTERSNAP on Unsplash
Abstract
This paper critically examines how US bioethics and health law conceptualize patient autonomy, contrasting the rights-based, individualist...
Impact and Correction of an Anterior Phakic Intraocular Lens on Swept-Source Optical Coherence Tomography Biometry
Impact and Correction of an Anterior Phakic Intraocular Lens on Swept-Source Optical Coherence Tomography Biometry
Purpose:
To evaluate the impact of anterior chamber phakic intraocular lens (pIOL) on swept-source optical coherence tomography (SS-OCT) biometric measurements and IOL ...
Treatment Trends in Dry Eye Disease and Factors Associated with Ophthalmic Follow-up Discontinuation in Japan
Treatment Trends in Dry Eye Disease and Factors Associated with Ophthalmic Follow-up Discontinuation in Japan
Despite the importance of dry eye disease (DED) treatment, the rate of DED treatment discontinuation, especially discontinuation of ophthalmic follow-up, remains unknown. This stud...
Field Experiments of Hyporheic Flow Affected by a Clay Lens
Field Experiments of Hyporheic Flow Affected by a Clay Lens
As a typical water exchange of surface water and groundwater, hyporheic flow widely exists in streambeds and is significantly affected by the characteristics of sediment and surfac...
Movable optical lens array using acoustic radiation force
Movable optical lens array using acoustic radiation force
A movable optical lens array that utilizes acoustic radiation force was investigated. The lens array consists of a rectangular glass plate, two piezoelectric bimorph transducers, a...
THE ANALYSIS OF a-CRYSTALLINE PROTEIN IN WHITE AND BRUNESCENT CATARACT
THE ANALYSIS OF a-CRYSTALLINE PROTEIN IN WHITE AND BRUNESCENT CATARACT
Objectives: The objectives of the study were to determine the difference of concentration and expression of α-crystalline protein in white and brunescent cataract lenses.
Methods: ...

