Javascript must be enabled to continue!
Enhancement of the Thermal Performance Characteristics of an Electrical Power Transformer
View through CrossRef
A 3D numerical simulation was conducted to test the effects of the geometrical and operational parameters on the cooling performance of a three-phase electrical distribution transformer (250 kVA oil natural air natural (ONAN)). The geometric parameters include the shape of the transformer (rectangular, circular, and hexagonal), fins shape (rectangular, semicircular, and trapezoidal) as well it arrangement (asymmetric fin heights and perforated fins). Both of oil temperature and thermal load have been used as boundary conditions. In order to verify the reliability of the numerical model, comparison between numerical results and experimental finding has been done. The results have indicated that the circular and hexagonal shapes reduced the average oil temperature by 3.4% and 4.7%, respectively, compared to the traditional transformer shape (rectangular). Furthermore, the lowest average oil temperature was observed for the trapezoidal fin, followed by the rectangular and semicircular fins. Additionally, it has been noticed that the asymmetric fin heights of the trapezoidal and perforated trapezoidal fins been contributed to the improvement of the cooling performance of the transformer. Furthermore, the best thermal performance was obtained with the trapezoidal perforated fin to compared other arrangement of fins. Finally, the highest reduction in oil has been obtained by the use of hexagonal transformer with a perforated trapezoidal fin approximately by 12% compared to traditional rectangular transformer. Hence, it can be concluded that the shape of the transformer and fins play an important role in thermal performance of such systems.
Universal Wiser Publisher Pte. Ltd
Title: Enhancement of the Thermal Performance Characteristics of an Electrical Power Transformer
Description:
A 3D numerical simulation was conducted to test the effects of the geometrical and operational parameters on the cooling performance of a three-phase electrical distribution transformer (250 kVA oil natural air natural (ONAN)).
The geometric parameters include the shape of the transformer (rectangular, circular, and hexagonal), fins shape (rectangular, semicircular, and trapezoidal) as well it arrangement (asymmetric fin heights and perforated fins).
Both of oil temperature and thermal load have been used as boundary conditions.
In order to verify the reliability of the numerical model, comparison between numerical results and experimental finding has been done.
The results have indicated that the circular and hexagonal shapes reduced the average oil temperature by 3.
4% and 4.
7%, respectively, compared to the traditional transformer shape (rectangular).
Furthermore, the lowest average oil temperature was observed for the trapezoidal fin, followed by the rectangular and semicircular fins.
Additionally, it has been noticed that the asymmetric fin heights of the trapezoidal and perforated trapezoidal fins been contributed to the improvement of the cooling performance of the transformer.
Furthermore, the best thermal performance was obtained with the trapezoidal perforated fin to compared other arrangement of fins.
Finally, the highest reduction in oil has been obtained by the use of hexagonal transformer with a perforated trapezoidal fin approximately by 12% compared to traditional rectangular transformer.
Hence, it can be concluded that the shape of the transformer and fins play an important role in thermal performance of such systems.
Related Results
Automatic Load Sharing of Transformer
Automatic Load Sharing of Transformer
Transformer plays a major role in the power system. It works 24 hours a day and provides power to the load. The transformer is excessive full, its windings are overheated which lea...
[RETRACTED] Rhino XL Male Enhancement v1
[RETRACTED] Rhino XL Male Enhancement v1
[RETRACTED]Rhino XL Reviews, NY USA: Studies show that testosterone levels in males decrease constantly with growing age. There are also many other problems that males face due ...
Thermal Effects in High Compactness CEA Stack
Thermal Effects in High Compactness CEA Stack
Thermal management is a pivotal aspect of stack durability and system operability. Consequently, understanding the thermal mapping within a stack based on its operating conditions ...
High frequency modeling of power transformers under transients
High frequency modeling of power transformers under transients
This thesis presents the results related to high frequency modeling of power transformers. First, a 25kVA distribution transformer under lightning surges is tested in the laborator...
EPD Electronic Pathogen Detection v1
EPD Electronic Pathogen Detection v1
Electronic pathogen detection (EPD) is a non - invasive, rapid, affordable, point- of- care test, for Covid 19 resulting from infection with SARS-CoV-2 virus. EPD scanning techno...
LIFE CYCLE OF TRANSFORMER 110/X KV AND ITS VALUE
LIFE CYCLE OF TRANSFORMER 110/X KV AND ITS VALUE
In a deregulated environment, power companies are in the constant process of reducing the costs of operating power facilities, with the aim of optimally improving the quality of de...
ANALISIS PENGARUH MASA OPERASIONAL TERHADAP PENURUNAN KAPASITAS TRANSFORMATOR DISTRIBUSI DI PT PLN (PERSERO)
ANALISIS PENGARUH MASA OPERASIONAL TERHADAP PENURUNAN KAPASITAS TRANSFORMATOR DISTRIBUSI DI PT PLN (PERSERO)
One cause the interruption of transformer is loading that exceeds the capabilities of the transformer. The state of continuous overload will affect the age of the transformer and r...
PLC Based Load Sharing of Transformers
PLC Based Load Sharing of Transformers
The transformer is very expensive and bulky power system equipment. It runs and feed the load for 24 hours a day. Sometimes the load on the transformer unexpectedly rises above its...

