Javascript must be enabled to continue!
Mechanistic Modeling of Electrical Submersible Pump ESP Boosting Pressure Under Gassy Flow Conditions and Experimental Validation
View through CrossRef
Abstract
As an artificial lift method for high-flow-rate oil production, electrical submersible pumps’ (ESP) performance surfers from gas entrainment, a frequently encountered phenomenon in ESPs. When it occurs, ESPs can experience moderate or severe head degradation accompanied with production rate reduction, gas locking and flow instabilities. For the design and operation of an ESP-based production system, the accurate model is needed to predict ESP boosting pressure under gassy flow conditions. In this paper, a simplified mechanistic model is proposed to model gas-liquid flow inside a rotating ESP. The model not only maps flow patterns in ESPs but also captures the multiphase flow characteristics in terms of in-situ gas void fraction, boosting pressure, bubble size, etc.
The experimental facility for testing ESP gas-liquid performance comprises of a 3″ stainless steel fully closed liquid flow loop and ½″ semi-open gas flow loop. A radial-type ESP with 14 stages, assembled in series, was horizontally mounted on the testing rig. Pressure ports were drilled at each stage to measure stage-by-stage pressure increment. The mixture of gas and liquid is separated in a horizontal separator, where excessive gas was vented and the liquid continues circulation. Experimental data were acquired with two types of tests (mapping tests and surging tests) to completely evaluate the pump behaviors at different operational conditions. The water/gas flow rates, ESP rotational speeds, intake pressure etc. were controlled in the experiments.
The new model starts form from Euler equations, and introduces a best-match flowrate at which the flow direction at ESP impeller outlet matches the designed flow direction. The mismatch of velocity triangle in a rotating impeller results from the varying liquid flow rates. Losses due to flow direction change, friction, and leakage etc., were incorporated in the model. Based on the force balance on a stable gas bubble in a centrifugal flow field, the in-situ gas void fraction inside a rotating ESP impeller can be estimated, from which the gas-liquid mixture density is calculated. The predicted ESP boosting pressures match the corresponding experimental measurements with acceptable accuracy.
Title: Mechanistic Modeling of Electrical Submersible Pump ESP Boosting Pressure Under Gassy Flow Conditions and Experimental Validation
Description:
Abstract
As an artificial lift method for high-flow-rate oil production, electrical submersible pumps’ (ESP) performance surfers from gas entrainment, a frequently encountered phenomenon in ESPs.
When it occurs, ESPs can experience moderate or severe head degradation accompanied with production rate reduction, gas locking and flow instabilities.
For the design and operation of an ESP-based production system, the accurate model is needed to predict ESP boosting pressure under gassy flow conditions.
In this paper, a simplified mechanistic model is proposed to model gas-liquid flow inside a rotating ESP.
The model not only maps flow patterns in ESPs but also captures the multiphase flow characteristics in terms of in-situ gas void fraction, boosting pressure, bubble size, etc.
The experimental facility for testing ESP gas-liquid performance comprises of a 3″ stainless steel fully closed liquid flow loop and ½″ semi-open gas flow loop.
A radial-type ESP with 14 stages, assembled in series, was horizontally mounted on the testing rig.
Pressure ports were drilled at each stage to measure stage-by-stage pressure increment.
The mixture of gas and liquid is separated in a horizontal separator, where excessive gas was vented and the liquid continues circulation.
Experimental data were acquired with two types of tests (mapping tests and surging tests) to completely evaluate the pump behaviors at different operational conditions.
The water/gas flow rates, ESP rotational speeds, intake pressure etc.
were controlled in the experiments.
The new model starts form from Euler equations, and introduces a best-match flowrate at which the flow direction at ESP impeller outlet matches the designed flow direction.
The mismatch of velocity triangle in a rotating impeller results from the varying liquid flow rates.
Losses due to flow direction change, friction, and leakage etc.
, were incorporated in the model.
Based on the force balance on a stable gas bubble in a centrifugal flow field, the in-situ gas void fraction inside a rotating ESP impeller can be estimated, from which the gas-liquid mixture density is calculated.
The predicted ESP boosting pressures match the corresponding experimental measurements with acceptable accuracy.
Related Results
Electric Submersible Pump Setting Depth Optimization- A Field Case Study
Electric Submersible Pump Setting Depth Optimization- A Field Case Study
Abstract
Well completion design consideration, in artificially-lifted wells, are typically governed by the philosophy of operators and dictated by the conditions and...
Utilizing Chelating Agent System Fluid to Remove Scale Buildup from Stuck ESP Shaft in Offshore Saudi Arabia
Utilizing Chelating Agent System Fluid to Remove Scale Buildup from Stuck ESP Shaft in Offshore Saudi Arabia
Abstract
Saudi Aramco’s first offshore field produced by electrical submersible pumps (ESPs) has completed a nine year operating cycle, sustaining the field producti...
Review of Numerical Simulation Research on Submersible Mixer for Sewage
Review of Numerical Simulation Research on Submersible Mixer for Sewage
Submersible mixer is the core machinery of sewage treatment, which has a profound effect on the efficiency and performance of the submersible mixing system of sewage treatment. Thi...
Need a Lift? A Rotary Gear Pump, an ESP System Without the ESP Pump
Need a Lift? A Rotary Gear Pump, an ESP System Without the ESP Pump
Abstract
Electric submersible pump (ESP) systems have over many decades proven themselves as a reliable Industry leading lift system. However, there are limitations ...
Extending ESP Run Life in Gassy Wells Application
Extending ESP Run Life in Gassy Wells Application
Abstract
The Electrical Submersible Pump (ESP) technology has dramatically evolved not only to cover wider inflow ranges but also to deal with abrupt gas conditions ...
Analyzing Well Performance VII
Analyzing Well Performance VII
Introduction
Analyzing well performance is an important step toward increasing profits by improving production techniques. The analysis is made by field tests and...
Advanced Analytics for Data-Driven Decision Making in Electrical Submersible Pump Operations Management
Advanced Analytics for Data-Driven Decision Making in Electrical Submersible Pump Operations Management
Abstract
Increasing demand for cost-cutting measures has seen the petroleum industry taking advantage of new technology to accelerate production and increase ultimat...
EPD Electronic Pathogen Detection v1
EPD Electronic Pathogen Detection v1
Electronic pathogen detection (EPD) is a non - invasive, rapid, affordable, point- of- care test, for Covid 19 resulting from infection with SARS-CoV-2 virus. EPD scanning techno...