Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Small-Disturbance Stability Analysis of Doubly Fed Variable-Speed Pumped Storage Units

View through CrossRef
The variable-speed operation mode of pumped storage units improves the regulation performance and endows the units with characteristics such as isolation from the power grid, thereby affecting the system stability. This study establishes a detailed mathematical model for the connection of doubly fed induction generator-based variable-speed pumped storage (DFIG-VSPS) to a single-machine infinite bus system under power generation conditions in the synchronous rotation direct-quadrature-zero coordinate system. The introduction of the eigenvalue method to analyze the small-disturbance stability of doubly fed variable-speed pumped storage units and the use of participation factors to calculate the degree of influence of each state variable on the small-disturbance stability of the units are innovations of this study. The participation factor enhances flexibility, continuity, and efficiency in doubly fed variable-speed pumped storage by optimizing dynamic power paths and enabling multi-objective control coordination. While eigenvalue analysis is not new, this study is the first to apply it with participation factors to DFIG-VSPS, addressing gaps in prior simplified models. Furthermore, based on the changes in the characteristic root trajectories, the influence of changes in the speed control system parameters and converter controller parameters on the system stability was determined. Finally, the conclusions obtained were verified through simulation. The results indicate that increasing the time constant of water flow inertia poses a risk of system instability, and the increase in proportional parameters and decrease in integral parameters of the power outer loop controller significantly affect the system stability.
Title: Small-Disturbance Stability Analysis of Doubly Fed Variable-Speed Pumped Storage Units
Description:
The variable-speed operation mode of pumped storage units improves the regulation performance and endows the units with characteristics such as isolation from the power grid, thereby affecting the system stability.
This study establishes a detailed mathematical model for the connection of doubly fed induction generator-based variable-speed pumped storage (DFIG-VSPS) to a single-machine infinite bus system under power generation conditions in the synchronous rotation direct-quadrature-zero coordinate system.
The introduction of the eigenvalue method to analyze the small-disturbance stability of doubly fed variable-speed pumped storage units and the use of participation factors to calculate the degree of influence of each state variable on the small-disturbance stability of the units are innovations of this study.
The participation factor enhances flexibility, continuity, and efficiency in doubly fed variable-speed pumped storage by optimizing dynamic power paths and enabling multi-objective control coordination.
While eigenvalue analysis is not new, this study is the first to apply it with participation factors to DFIG-VSPS, addressing gaps in prior simplified models.
Furthermore, based on the changes in the characteristic root trajectories, the influence of changes in the speed control system parameters and converter controller parameters on the system stability was determined.
Finally, the conclusions obtained were verified through simulation.
The results indicate that increasing the time constant of water flow inertia poses a risk of system instability, and the increase in proportional parameters and decrease in integral parameters of the power outer loop controller significantly affect the system stability.

Related Results

Stability Modeling and Analysis of Grid Connected Doubly Fed Wind Energy Generation Based on Small Signal Model
Stability Modeling and Analysis of Grid Connected Doubly Fed Wind Energy Generation Based on Small Signal Model
Stable wind power generation can ensure the quality of power transmitted by the grid. The application of large-scale grid-connected wind power systems will induce problems such as ...
Modelling and control of doubly fed variable‐speed pumped storage units for grid power regulation
Modelling and control of doubly fed variable‐speed pumped storage units for grid power regulation
With the expending scale of the power grid and the substantial development of renewable energy generation system, the demand for power quality is becoming more and more significant...
Pumped Storage Hydropower for Sustainable and Low-Carbon Electricity Grids in Pacific Rim Economies
Pumped Storage Hydropower for Sustainable and Low-Carbon Electricity Grids in Pacific Rim Economies
Because generating electricity significantly contributes to global greenhouse gas emissions, meeting the 2015 Paris Agreement and 2021 Glasgow Climate Pact requires rapidly transit...
Development Situation and Relevant Inspiration of Pumped Storage Power Station in the world
Development Situation and Relevant Inspiration of Pumped Storage Power Station in the world
Abstract In many countries, pumped storage power stations have gradually become management tools for the power system and are used to meet peak-shaving, valley filli...
Effects of Voltage Sags on the Doubly Fed induction Generator using PI Controllers
Effects of Voltage Sags on the Doubly Fed induction Generator using PI Controllers
The paper presents dynamic and transient behaviour of the Doubly Fed Induction Generator (DFIG) in the wind farms. When Voltage sag or any faults occurs in the network, the variabl...
Research on Selection of Different Speed Units for Super High Water Head and Large Capicity Pumped Storage Power Station
Research on Selection of Different Speed Units for Super High Water Head and Large Capicity Pumped Storage Power Station
Abstract Changlongshan pumped storage power station is the one with the highest water head and the highest unit speed among the single-stage large capacity pumped st...