Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Measurement of Ozone Production Sensor

View through CrossRef
Abstract. A new ambient air monitor, the Measurement of Ozone Production Sensor (MOPS), measures directly the rate of ozone production in the atmosphere. The sensor consists of two 11.3 L environmental chambers made of UV-transmitting Teflon film, a unit to convert NO2 to O3, and a modified ozone monitor. In the sample chamber, flowing ambient air is exposed to the sunlight so that ozone is produced just as it is in the atmosphere. In the second chamber, called the reference chamber, a UV-blocking film over the Teflon film prevents ozone formation but allows other processes to occur as they do in the sample chamber. The air flows that exit the two chambers are sampled by an ozone monitor operating in differential mode so that the difference between the two ozone signals, divided by the exposure time in the chambers, gives the ozone production rate. High-efficiency conversion of NO2 to O3 prior to detection in the ozone monitor accounts for differences in the NOx photostationary state that can occur in the two chambers. The MOPS measures the ozone production rate, but with the addition of NO to the sampled air flow, the MOPS can be used to study the sensitivity of ozone production to NO. Preliminary studies with the MOPS on the campus of the Pennsylvania State University show the potential of this new technique.
Title: Measurement of Ozone Production Sensor
Description:
Abstract.
A new ambient air monitor, the Measurement of Ozone Production Sensor (MOPS), measures directly the rate of ozone production in the atmosphere.
The sensor consists of two 11.
3 L environmental chambers made of UV-transmitting Teflon film, a unit to convert NO2 to O3, and a modified ozone monitor.
In the sample chamber, flowing ambient air is exposed to the sunlight so that ozone is produced just as it is in the atmosphere.
In the second chamber, called the reference chamber, a UV-blocking film over the Teflon film prevents ozone formation but allows other processes to occur as they do in the sample chamber.
The air flows that exit the two chambers are sampled by an ozone monitor operating in differential mode so that the difference between the two ozone signals, divided by the exposure time in the chambers, gives the ozone production rate.
High-efficiency conversion of NO2 to O3 prior to detection in the ozone monitor accounts for differences in the NOx photostationary state that can occur in the two chambers.
The MOPS measures the ozone production rate, but with the addition of NO to the sampled air flow, the MOPS can be used to study the sensitivity of ozone production to NO.
Preliminary studies with the MOPS on the campus of the Pennsylvania State University show the potential of this new technique.

Related Results

Dynamic stochastic modeling for inertial sensors
Dynamic stochastic modeling for inertial sensors
Es ampliamente conocido que los modelos de error para sensores inerciales tienen dos componentes: El primero es un componente determinista que normalmente es calibrado por el fabri...
Novel intrathoracic irrigation using ultrafine ozone bubbles in a rat empyema model
Novel intrathoracic irrigation using ultrafine ozone bubbles in a rat empyema model
AbstractDissolved ozone is generally used for sanitization, but it has not been used for thoracic cavity sanitization because of its short half-life (< 20 min) and possible toxi...
Novel intrathoracic irrigation using ultrafine ozone bubbles in a rat empyema model
Novel intrathoracic irrigation using ultrafine ozone bubbles in a rat empyema model
Abstract Dissolved ozone is generally used for sanitization, but it has not been used for thoracic cavity sanitization because of its short half-life (< 20 min) and poss...
Interannual variability in ozone damage to tropical forests
Interannual variability in ozone damage to tropical forests
Fire emissions include the ozone precursor NOx, which is often the limiting precursor in remote locations such as the tropical forests. In fact, interannual variability in tropical...
Effect of ozone and 10% sodium ascorbate on human dentin microhardness
Effect of ozone and 10% sodium ascorbate on human dentin microhardness
: Several strategies have been tried out for the control and antimicrobial treatment of carious lesions such as the direct application of ozone. However, the the oxidation process ...
Association between low drying temperature and ozonation process to control pest and preserve the maize quality
Association between low drying temperature and ozonation process to control pest and preserve the maize quality
Maize is one of the cereals major produced for its nutritional and energy characteristics and that has become one of the most cultivated crop in the world. To maintain high quality...
Varietal Tolerance of Tobacco to Ozone Dose Rate
Varietal Tolerance of Tobacco to Ozone Dose Rate
AbstractWe determined the relative degree of ozone injury to genetically susceptible and resistant tobacco (Nicotiana tabacum L.) plants in studies of ozone tolerance. Essentially ...
Secondary maxima in ozone profiles
Secondary maxima in ozone profiles
Abstract. Ozone profiles from balloon soundings as well as SAGE II ozone profiles were used to detect anomalous large ozone concentrations of ozone in the lower stratosphere. These...

Back to Top