Effects of a Sprinkler on Evacuation Dynamics in Fire

View through CrossRef
A fire in an enclosed space, such as a room in a building, is generally called a compartment fire. To prevent the compartment fire, a sprinkler for first-aid fire-fighting is installed in rooms. However, it is difficult to determine the degree to which smoke generation and the fire spreading will be inhibited when sprinklers are on. In particular, demonstrating evacuation behavior assuming an actual fire is impossible. In this study, we evaluated an effectiveness of the sprinkler by numerical simulations. To consider evacuation dynamics, a real-coded cellular automata (RCA) was used, where we can freely set the direction and velocity of an evacuee based on a floor field model. To consider the situation in the room fire, we used a simulator called Fire Dynamics Simulator (FDS). Two cases with and without the sprinkler were compared to see the validity of the sprinkler on evacuation dynamics. The effect of smoke and the expansion of the fire-spreading region were discussed. Results show that, since the fire-spreading region disappears when the sprinkler is actuated, the evacuation time decreases. Even though the sprinkler is actuated, the smoke generated at the beginning of a fire diffuses inside the whole room. However, the duration of evacuees being overwhelmed by smoke is less, because the amount of smoke generated by the pyrolysis reaction is much decreased.
Title: Effects of a Sprinkler on Evacuation Dynamics in Fire
Description:
A fire in an enclosed space, such as a room in a building, is generally called a compartment fire.
To prevent the compartment fire, a sprinkler for first-aid fire-fighting is installed in rooms.
However, it is difficult to determine the degree to which smoke generation and the fire spreading will be inhibited when sprinklers are on.
In particular, demonstrating evacuation behavior assuming an actual fire is impossible.
In this study, we evaluated an effectiveness of the sprinkler by numerical simulations.
To consider evacuation dynamics, a real-coded cellular automata (RCA) was used, where we can freely set the direction and velocity of an evacuee based on a floor field model.
To consider the situation in the room fire, we used a simulator called Fire Dynamics Simulator (FDS).
Two cases with and without the sprinkler were compared to see the validity of the sprinkler on evacuation dynamics.
The effect of smoke and the expansion of the fire-spreading region were discussed.
Results show that, since the fire-spreading region disappears when the sprinkler is actuated, the evacuation time decreases.
Even though the sprinkler is actuated, the smoke generated at the beginning of a fire diffuses inside the whole room.
However, the duration of evacuees being overwhelmed by smoke is less, because the amount of smoke generated by the pyrolysis reaction is much decreased.

Related Results

Construction and Validation of Sprinkler Pattern Radius Computational Model
Construction and Validation of Sprinkler Pattern Radius Computational Model
Abstract In ascertaining the sprinkler and micro-sprinkler computational approach. computing models of sprinkler pattern radius were generated in accordance with hydraulic ...
Enhancing Radiological Emergency Response through Agent-Based Model Case 1: Effectiveness of staged Evacuation
Enhancing Radiological Emergency Response through Agent-Based Model Case 1: Effectiveness of staged Evacuation
Abstract In the event of radiological emergencies, such as nuclear accidents, the speedy but well-ordering evacuation of residents in imperative to ensure their health and ...
Rancangan Irigasi Sprinkler Portable Tanaman Pakchoy
Rancangan Irigasi Sprinkler Portable Tanaman Pakchoy
Salah satu teknologi yang dapat meningkatkan efisiensi dan efektivitas penggunaan air irigasi adalah irigasi sprinkler. Namun dalam penerapan sistem irigasi sprinkler di lapangan m...
Evacuation Performance
Evacuation Performance
Abstract Evacuation system performance deteriorates as weather conditions worsen. A research program based primarily on model scale tests of several different typ...
Model Construction and Verification of Sprinkler Pattern Radius Calculation
Model Construction and Verification of Sprinkler Pattern Radius Calculation
Abstract To determine Calculation method of sprinkler and micro-sprinklers, computational models of sprinkler pattern radius model is established which based on hydraulic p...
Optimization analysis of fire characteristics and emergency evacuation scheme of small- and medium-sized high-speed railway stations
Optimization analysis of fire characteristics and emergency evacuation scheme of small- and medium-sized high-speed railway stations
Abstract To study the fire spread law in high-speed railway stations and suggest a reasonable evacuation plan, we first establish a physical model based on a high-speed rai...
Case Studies on Evacuation Elevator Systems in Supertall Buildings
Case Studies on Evacuation Elevator Systems in Supertall Buildings
In 2009, the International Building Code (IBC) introduced a new requirement for an additional exit stair or evacuation elevators in buildings (except residential buildings) over 42...
Analisis Pemilihan Rute Evakuasi Menggunakan Metode AHP Di Kawasan Rawan Bencana Merapi
Analisis Pemilihan Rute Evakuasi Menggunakan Metode AHP Di Kawasan Rawan Bencana Merapi
Evacuation routes are important component during evacuation process, but sometimes the evacuation route conditions are not ready to use for evacuation. The good evacuation route ca...