Javascript must be enabled to continue!
Optimisation of power electronics for regulated transformer rectifier units
View through CrossRef
This study presents a comprehensive approach for the design optimisation of passive components and heatsinks in power electronic converters. The design and selection of passive components are posed as a multi‐objective optimisation problem, which can be simplified to a single‐objective optimisation based on preferences and weights assigned by the designer. The mathematical equations describing the efficiency, volume, and reliability are laid out to describe the feasible space for optimisation in this study. In addition to the proposed optimisation, a substantial amount of passive component comparison data has been consolidated and presented in this study. The results from the optimisation are demonstrated on the target power electronic circuit of a regulated transformer rectifier unit for more‐electric aircrafts. The optimisation framework is developed in a generic manner that would lend itself to the optimisation of any choice of converter topology, circuit components, or objective functions.
Institution of Engineering and Technology (IET)
Title: Optimisation of power electronics for regulated transformer rectifier units
Description:
This study presents a comprehensive approach for the design optimisation of passive components and heatsinks in power electronic converters.
The design and selection of passive components are posed as a multi‐objective optimisation problem, which can be simplified to a single‐objective optimisation based on preferences and weights assigned by the designer.
The mathematical equations describing the efficiency, volume, and reliability are laid out to describe the feasible space for optimisation in this study.
In addition to the proposed optimisation, a substantial amount of passive component comparison data has been consolidated and presented in this study.
The results from the optimisation are demonstrated on the target power electronic circuit of a regulated transformer rectifier unit for more‐electric aircrafts.
The optimisation framework is developed in a generic manner that would lend itself to the optimisation of any choice of converter topology, circuit components, or objective functions.
Related Results
Automatic Load Sharing of Transformer
Automatic Load Sharing of Transformer
Transformer plays a major role in the power system. It works 24 hours a day and provides power to the load. The transformer is excessive full, its windings are overheated which lea...
Z‐source matrix rectifier
Z‐source matrix rectifier
This study presents a novel Z‐source matrix rectifier (ZSMR). To overcome the inherent disadvantage that the voltage transfer ratio for traditional matrix rectifier (MR) cannot be ...
LIFE CYCLE OF TRANSFORMER 110/X KV AND ITS VALUE
LIFE CYCLE OF TRANSFORMER 110/X KV AND ITS VALUE
In a deregulated environment, power companies are in the constant process of reducing the costs of operating power facilities, with the aim of optimally improving the quality of de...
ANALISIS PENGARUH MASA OPERASIONAL TERHADAP PENURUNAN KAPASITAS TRANSFORMATOR DISTRIBUSI DI PT PLN (PERSERO)
ANALISIS PENGARUH MASA OPERASIONAL TERHADAP PENURUNAN KAPASITAS TRANSFORMATOR DISTRIBUSI DI PT PLN (PERSERO)
One cause the interruption of transformer is loading that exceeds the capabilities of the transformer. The state of continuous overload will affect the age of the transformer and r...
Safe Rectifier Design for Cathodic Protection
Safe Rectifier Design for Cathodic Protection
Abstract
Rectifier safety has recently become an industry concern for cathodic protection technicians and personnel who are responsible for rectifier operation, main...
PLC Based Load Sharing of Transformers
PLC Based Load Sharing of Transformers
The transformer is very expensive and bulky power system equipment. It runs and feed the load for 24 hours a day. Sometimes the load on the transformer unexpectedly rises above its...
Simulation modeling study on short circuit ability of distribution transformer
Simulation modeling study on short circuit ability of distribution transformer
Abstract
Under short circuit condition, the oil immersed distribution transformer will endure combined electro-thermal stress, eventually lead to the mechanical dama...
Resonant Converter with Voltage-Doubler Rectifier or Full-Bridge Rectifier for Wide-Output Voltage and High-Power Applications
Resonant Converter with Voltage-Doubler Rectifier or Full-Bridge Rectifier for Wide-Output Voltage and High-Power Applications
This paper presents a resonant converter with the benefits of wide output voltage, wide soft switching characteristics for power devices and high circuit efficiency. Since the seri...