Javascript must be enabled to continue!
Limits for resolving tandem mass tag reporter ions with identical integer mass using phase constrained spectrum deconvolution
View through CrossRef
ABSTRACTA popular method for peptide quantification relies on isobaric labeling such as tandem mass tags (TMT) which enables multiplexed proteome analyses. Quantification is achieved by reporter ions generated by fragmentation in a tandem mass spectrometer. However, with higher degrees of multiplexing, the smaller mass differences between the reporter ions increase the mass resolving power requirements. This contrasts with faster peptide sequencing capabilities enabled by lowered mass resolution on Orbitrap instruments. It is therefore important to determine the mass resolution limits for highly multiplexed quantification when maximizing proteome depth. Here we defined the lower boundaries for resolving TMT reporter ions with 0.0063 Da mass differences using an ultra-high-field Orbitrap mass spectrometer. We found the optimal method depends on the relative ratio between closely spaced reporter ions and that 64 ms transient acquisition time provided sufficient resolving power for separating TMT reporter ions with absolute ratio changes up to 16-fold. Furthermore, a 32 ms transient processed with phase-constrained spectrum deconvolution provides >50% more identifications with >99% quantified, but with a slight loss in quantification precision and accuracy. These findings should guide decisions on what Orbitrap resolution settings to use in future proteomics experiments relying on TMT reporter ion quantification with identical integer masses.
Cold Spring Harbor Laboratory
Title: Limits for resolving tandem mass tag reporter ions with identical integer mass using phase constrained spectrum deconvolution
Description:
ABSTRACTA popular method for peptide quantification relies on isobaric labeling such as tandem mass tags (TMT) which enables multiplexed proteome analyses.
Quantification is achieved by reporter ions generated by fragmentation in a tandem mass spectrometer.
However, with higher degrees of multiplexing, the smaller mass differences between the reporter ions increase the mass resolving power requirements.
This contrasts with faster peptide sequencing capabilities enabled by lowered mass resolution on Orbitrap instruments.
It is therefore important to determine the mass resolution limits for highly multiplexed quantification when maximizing proteome depth.
Here we defined the lower boundaries for resolving TMT reporter ions with 0.
0063 Da mass differences using an ultra-high-field Orbitrap mass spectrometer.
We found the optimal method depends on the relative ratio between closely spaced reporter ions and that 64 ms transient acquisition time provided sufficient resolving power for separating TMT reporter ions with absolute ratio changes up to 16-fold.
Furthermore, a 32 ms transient processed with phase-constrained spectrum deconvolution provides >50% more identifications with >99% quantified, but with a slight loss in quantification precision and accuracy.
These findings should guide decisions on what Orbitrap resolution settings to use in future proteomics experiments relying on TMT reporter ion quantification with identical integer masses.
Related Results
Klauder wavelet removal before vibroseis deconvolution
Klauder wavelet removal before vibroseis deconvolution
The spiking deconvolution of a field seismic trace requires that the seismic wavelet on the trace be minimum phase. On a dynamite trace, the component wavelets due to the effects o...
Restoring Erroneous or Missing Rates in Interfering Wells Using Multiwell Deconvolution
Restoring Erroneous or Missing Rates in Interfering Wells Using Multiwell Deconvolution
Abstract
Objectives/Scope
Single well deconvolution (von Schroeter et al., 2001) has been added to the well test interpretation ...
Sparsity‐enhanced wavelet deconvolution
Sparsity‐enhanced wavelet deconvolution
ABSTRACTWe propose a three‐step bandwidth enhancing wavelet deconvolution process, combining linear inverse filtering and non‐linear reflectivity construction based on a sparseness...
Mass spectrometry of oligosaccharides
Mass spectrometry of oligosaccharides
Abstract
I.
Introduction
162
II.
CHARACTERISTICS OF TANDEM MASS SPECTRA OF CARBOHYDRATES
163
A. Ionization of Carbohydrates
163
1. Electrospray Ionization (E...
The development of a cometosheath at comet 67P Churyumov-Gerasimenko
The development of a cometosheath at comet 67P Churyumov-Gerasimenko
Introduction: The Rosetta spacecraft followed the comet 67P/Churyumov-Gerasimenko for two years, through the atmosphere expanding and subsequently contracting with solar distance a...
Isolation, characterization and semi-synthesis of natural products dimeric amide alkaloids
Isolation, characterization and semi-synthesis of natural products dimeric amide alkaloids
Isolation, characterization of natural products dimeric amide alkaloids from roots of the Piper chaba Hunter. The synthesis of these products using intermolecular [4+2] cycloaddit...
The Black Mass as Play: Dennis Wheatley's The Devil Rides Out
The Black Mass as Play: Dennis Wheatley's The Devil Rides Out
Literature—at least serious literature—is something that we work at. This is especially true within the academy. Literature departments are places where workers labour over texts c...
Template E-commerce Dinda Wulandari 16011106
Template E-commerce Dinda Wulandari 16011106
1.Tag untuk menentukan tipe dokumen2.Tag ini digunakan untuk membuat Background belakang dari website3.Tag untuk membuat sebuah dokumen HTML4.Tag untuk membuat judul dari sebuah ha...

