A Novel Analytical approach for Simultaneous Estimation of Esomeprazole and Ondansetron by HPLC-DAD Method with Degradation Studies
View through CrossRef
Objective: A simultaneous estimation of Esomeprazole and Ondansetron by HPLC-DAD method with degradation studies was developed. Method: It was carried out using Kromasil (150mm×4.6mm, 5µm particle size) column with mobile phase consists 0.01M KH2PO4 Phosphate buffer (1mL of Triethylamine added and pH was adjusted to 3.5 with Orthophosphoric acid): Acetonitrile (35:65, %v/v) with flow rate 1mL/min at 265nm. Esomeprazole and Ondansetron were eluted at 2.350 and 2.831mins respectively. Results and Discussion: Validation was performed as per ICH guidelines, which shows linearity 25-150μg/mL of Esomeprazole and 10-60μg/mL of Ondansetron with R2 was 0.999. Accuracy was obtained to be 99.75-100.21% for Esomeprazole and 99.39-100.3% for Ondansetron respectively and precision which shows %RSD less than 2%. Stress studies were carried out which shows that both Esomeprazole and Ondansetron is moderately degraded in acid, base, peroxide and thermal degradation and less degraded in photolytic degradation. Conclusion: This method was applicable for routine analysis and stability of Esomeprazole and Ondansetron.
Title: A Novel Analytical approach for Simultaneous Estimation of Esomeprazole and Ondansetron by HPLC-DAD Method with Degradation Studies
Description:
Objective: A simultaneous estimation of Esomeprazole and Ondansetron by HPLC-DAD method with degradation studies was developed.
Method: It was carried out using Kromasil (150mm×4.
6mm, 5µm particle size) column with mobile phase consists 0.
01M KH2PO4 Phosphate buffer (1mL of Triethylamine added and pH was adjusted to 3.
5 with Orthophosphoric acid): Acetonitrile (35:65, %v/v) with flow rate 1mL/min at 265nm.
Esomeprazole and Ondansetron were eluted at 2.
350 and 2.
831mins respectively.
Results and Discussion: Validation was performed as per ICH guidelines, which shows linearity 25-150μg/mL of Esomeprazole and 10-60μg/mL of Ondansetron with R2 was 0.
999.
Accuracy was obtained to be 99.
75-100.
21% for Esomeprazole and 99.
39-100.
3% for Ondansetron respectively and precision which shows %RSD less than 2%.
Stress studies were carried out which shows that both Esomeprazole and Ondansetron is moderately degraded in acid, base, peroxide and thermal degradation and less degraded in photolytic degradation.
Conclusion: This method was applicable for routine analysis and stability of Esomeprazole and Ondansetron.
Related Results
Kupfer(I)-Komplexe mit ungesättigten Stickstoffliganden, V / Kupfer(I)-Komplexe mit Diazadienen als Chelate und Brücken: Röntgenstrukturenuntersuchungen an (DAD)Cu(μ-Cl)2Cu(DAD), [(DAD)2Cu]⁺ (CuCl2)-, (DAD)CuCl, [μ-(DAD)2Cu5Cl5]n und [μ-(DAD)Cu(OTf)]n (DA
Kupfer(I)-Komplexe mit ungesättigten Stickstoffliganden, V / Kupfer(I)-Komplexe mit Diazadienen als Chelate und Brücken: Röntgenstrukturenuntersuchungen an (DAD)Cu(μ-Cl)2Cu(DAD), [(DAD)2Cu]⁺ (CuCl2)-, (DAD)CuCl, [μ-(DAD)2Cu5Cl5]n und [μ-(DAD)Cu(OTf)]n (DA
Diazadienes RN = CR′-CR′ = NR (DAD) form molecular complexes with copper(I) halides of composition (DAD)CuX, the structures of which vary from [(DAD)2Cu]+(CuCl2)⁻ with a non-tetrah...
A Review of Ondansetron in the Management of Radiotherapy-Induced Emesis
A Review of Ondansetron in the Management of Radiotherapy-Induced Emesis
This paper reviews experience with ondansetron in radiotherapy-induced emesis. The efficacy of ondansetron is assessed following a number of different radiotherapy regimens: single...
Oral Drug Absorption and Drug Disposition in Critically Ill Cardiac Patients
Oral Drug Absorption and Drug Disposition in Critically Ill Cardiac Patients
(1) Background: In critically ill cardiac patients, parenteral and enteral food and drug administration routes may be used. However, it is not well known how drug absorption and me...
Ruthenium-Komplexe mit Diazadienen, IX. Ein neuartiger Chromophor aus zwei Diazadien-Ruthenium-Einheiten — Struktur und Eigenschaften von [(CO)2(DAD)CH3Ru- RuCH3(DAD)(CO)2] (DAD = ipr—N=CH—CH=N —ipr) / Ruthenium Complexes with Diazadienes, IX. A New Chrom
Ruthenium-Komplexe mit Diazadienen, IX. Ein neuartiger Chromophor aus zwei Diazadien-Ruthenium-Einheiten — Struktur und Eigenschaften von [(CO)2(DAD)CH3Ru- RuCH3(DAD)(CO)2] (DAD = ipr—N=CH—CH=N —ipr) / Ruthenium Complexes with Diazadienes, IX. A New Chrom
The two-electron reduction of [(DAD)Ru(CO)2I2] (DAD = RN = CH -CH = NR ) gives the reactive ruthenates(O) [(DAD Ru(CO )2I]-, which add organic electrophiles to afford iodoruthenium...
EFFICACY AND COST-EFFECTIVENESS, COMPARISON OF 7-DAYS VONOPRAZAN VERSUS 14-DAYS ESOMEPRAZOLE BASED TRIPLE THERAPIES FOR TREATING HELICOBACTER PYLORI INFECTION IN PAKISTANI POPULATION: A RANDOMIZED CLINICAL TRIAL
EFFICACY AND COST-EFFECTIVENESS, COMPARISON OF 7-DAYS VONOPRAZAN VERSUS 14-DAYS ESOMEPRAZOLE BASED TRIPLE THERAPIES FOR TREATING HELICOBACTER PYLORI INFECTION IN PAKISTANI POPULATION: A RANDOMIZED CLINICAL TRIAL
Background: Helicobacter pylori (H. pylori) is a gram-negative bacterium which usually resides in the mucoid lining of the stomach and may cause different gastric pathologies e.g.,...
Esomeprazole-Induced Central Fever with Severe Myalgia
Esomeprazole-Induced Central Fever with Severe Myalgia
OBJECTIVE:
To report a case of central fever associated with severe myalgia following esomeprazole.
CA...
Outcome of ondansetron on subarachnoid block-induced hypotension in infraumbilical surgeries
Outcome of ondansetron on subarachnoid block-induced hypotension in infraumbilical surgeries
Background: Bradycardia and hypotension are common post-subarachnoid block (SAB) complications that can result in adverse outcomes. The 5-HT3 receptor antagonist ondansetron, which...
Comparative antiemetic efficacy of metoclopramide, ondansetron and pyridoxine for the prevention nausea and vomiting in patients undergoing cesarean section under spinal anesthesia
Comparative antiemetic efficacy of metoclopramide, ondansetron and pyridoxine for the prevention nausea and vomiting in patients undergoing cesarean section under spinal anesthesia
Introduction. One of the complications after Cesarean Section is nausea and vomiting, especially during spinal anesthesia. The main causes of nausea and vomiting are complex, and m...