Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Whether Sutures Reduce the Graft Laceration Caused by Interference Screw in Anterior Cruciate Ligament Reconstruction a Biomechanical Study in Vitro

View through CrossRef
Abstract Background: Interference screw is commonly used for graft fixation in anterior cruciate ligament (ACL) reconstruction However, previous studies h a d reported that the insertion of interference screws significantly caused graft laceration . The purpose of this study was to determine whether sutures reduce d the graft laceration from the insertion of interference screws in ACL reconstruction. Methods: Porcine tibias and bovine extensor tendons were used for establishing a knee model of ACL reconstruction in vitro . The ends of grafts were sutured using three different sutures, including the bioabsorbable, Ethibond and ultra high molecular weight polyethylene (UHMWPE) sutures Poly ether ether ketone (PEEK) interference screw s w ere used fortibial fixation Biomechanical tests were performed to investigate the protective effects of different sutures on grafts Results : All prepared tendons and bone specimens showed similar characteristics (length, weight, and pre tension of the tendons, tibial bone mineral density) among all groups ( P 0.05). The biomechanical test s demonstrated that PEEK interference screw s significantly caused the graft laceration P 0.05). However, all sutures (the bioabsorbable, Ethibond and UHMWPE sutures) did not reduce the graft laceration in ACL reconstruction P 0.05). Conclusions : PEEK interference screw s significantly weakened the biomechanical properties of grafts during tibial fixation in ACL reconstruction. Absorbable Ethibond and UHMWPE sutures did not provide protective effects on grafts during ACL reconstruction.
Title: Whether Sutures Reduce the Graft Laceration Caused by Interference Screw in Anterior Cruciate Ligament Reconstruction a Biomechanical Study in Vitro
Description:
Abstract Background: Interference screw is commonly used for graft fixation in anterior cruciate ligament (ACL) reconstruction However, previous studies h a d reported that the insertion of interference screws significantly caused graft laceration .
The purpose of this study was to determine whether sutures reduce d the graft laceration from the insertion of interference screws in ACL reconstruction.
Methods: Porcine tibias and bovine extensor tendons were used for establishing a knee model of ACL reconstruction in vitro .
The ends of grafts were sutured using three different sutures, including the bioabsorbable, Ethibond and ultra high molecular weight polyethylene (UHMWPE) sutures Poly ether ether ketone (PEEK) interference screw s w ere used fortibial fixation Biomechanical tests were performed to investigate the protective effects of different sutures on grafts Results : All prepared tendons and bone specimens showed similar characteristics (length, weight, and pre tension of the tendons, tibial bone mineral density) among all groups ( P 0.
05).
The biomechanical test s demonstrated that PEEK interference screw s significantly caused the graft laceration P 0.
05).
However, all sutures (the bioabsorbable, Ethibond and UHMWPE sutures) did not reduce the graft laceration in ACL reconstruction P 0.
05).
Conclusions : PEEK interference screw s significantly weakened the biomechanical properties of grafts during tibial fixation in ACL reconstruction.
Absorbable Ethibond and UHMWPE sutures did not provide protective effects on grafts during ACL reconstruction.

Related Results

Inside-Out Repair of Medial Meniscal Ramp Lesions in Patients Undergoing Anterior Cruciate Ligament Reconstruction
Inside-Out Repair of Medial Meniscal Ramp Lesions in Patients Undergoing Anterior Cruciate Ligament Reconstruction
Background: Medial meniscal ramp lesions are disruptions at the meniscocapsular junction and/or meniscotibial attachment of the posterior horn of the medial meniscus, a...
ANTERIOR CRUCIATE LIGAMENT, DESCRIPTION, RUPTURE AND TREATMENT
ANTERIOR CRUCIATE LIGAMENT, DESCRIPTION, RUPTURE AND TREATMENT
Introduction: the anterior cruciate ligament (ACL) along with the posterior cruciate ligament are the central stabilizers of the knee. Rupture of the ACL usually occurs in active a...
Morphological characteristics of the Lisfranc ligament
Morphological characteristics of the Lisfranc ligament
Abstract Background This study aimed to clarify the morphological characteristics of the Lisfranc ligament and the plantar ligament. Methods Forty legs from 20 cadavers w...
Economic comparison of methods of wound closure: wound closure strips versus sutures and wound adhesives
Economic comparison of methods of wound closure: wound closure strips versus sutures and wound adhesives
Comparaison économique des méthodes de fermeture des plaies: fermetures des plaies par sutures adhésives strips versus sutures et tissus adhésifsNotre objectif était de faire la re...
Preliminary Result of Arthroscopic Anterior Cruciate Ligament Reconstruction Using Anterior Half of Peroneus Longus Tendon Autograft
Preliminary Result of Arthroscopic Anterior Cruciate Ligament Reconstruction Using Anterior Half of Peroneus Longus Tendon Autograft
BACKGROUND: Anthroscopic anterior cruciate ligament reconstruction is one of the most successful operations in sports medicine. At present, ligament autografts have been the best m...
Sagittal Inclination Angle of the Graft Affects Graft Maturity and Knee Stability After Anterior Cruciate Ligament Reconstruction
Sagittal Inclination Angle of the Graft Affects Graft Maturity and Knee Stability After Anterior Cruciate Ligament Reconstruction
ABSTRACTObjectiveThe influence of the graft sagittal inclination angle (SIA) on knee stability, biomechanics, and graft maturity has been elucidated. However, no study has comprehe...
The Anterior Cruciate Ligament in Controlling Axial Rotation
The Anterior Cruciate Ligament in Controlling Axial Rotation
Changes in axial tibial rotation after anterior cruciate ligament sectioning were evaluated in 14 fresh human knee joints. Simulation of vertical stance in a quadriceps-stabilized ...

Back to Top