BackgroundThe subcutaneous implantable cardioverter-defibrillator (S-ICD) has been designed to overcome lead-related complications and device endocarditis. Lacking the ability for pacing or resynchronization therapy its usage is limited to selected patients at risk for sudden cardiac death (SCD).ObjectiveThe aim of this single-center study was to assess clinical outcomes of S-ICD and single-chamber transvenous (TV)-ICD in an all-comers population.MethodsThe study cohort comprised a total of 119 ICD patients who underwent either S-ICD (n = 35) or TV-ICD (n = 84) implantation at the University Hospital Frankfurt from 2009 to 2017. By applying an inverse probability-weighting (IPW) analysis based on the propensity score including the Charlson Comorbidity Index (CCI) to adjust for potential extracardiac comorbidities, we aimed for head-to-head comparison on the study composite endpoint: overall survival, hospitalization, and device-associated events (including appropriate and inappropriate shocks or system-related complications).ResultsThe median age of the study population was 66.0 years, 22.7% of the patients were female. The underlying heart disease was ischemic cardiomyopathy (61.4%) with a median LVEF of 30%. Only 52.9% had received an ICD for primary prevention, most of the patients (67.3%) had advanced heart failure (NYHA class II–III) and 16.8% were in atrial fibrillation. CCI was 5 points in TV-ICD patients vs. 4 points for patients with S-ICD (p = 0.209) indicating increased morbidity. The composite endpoint occurred in 38 patients (31.9 %), revealing no significant difference between patients implanted with an S-ICD or TV-ICD (unweighted HR 1.50, 95 % confidence interval (CI) 0.78–2.90; p = 0.229, weighted HR 0.94, 95% CI, 0.61–1.50, p = 0.777). Furthermore, we observed no difference in any single clinical endpoint or device-associated outcome, neither in the unweighted cohort nor following inverse probability-weighting.ConclusionClinical outcomes of the S-ICD and TV-ICD revealed no differences in the composite endpoint including survival, freedom of hospitalization and device-associated events, even after careful adjustment for potential confounders. Moreover, the CCI was evaluated in a S-ICD cohort demonstrating higher survival rates than predicted by the CCI in young, polymorbid (S-)ICD patients.
Title: Clinical outcomes of subcutaneous vs. transvenous implantable defibrillator therapy in a polymorbid patient cohort
Description:
BackgroundThe subcutaneous implantable cardioverter-defibrillator (S-ICD) has been designed to overcome lead-related complications and device endocarditis.
Lacking the ability for pacing or resynchronization therapy its usage is limited to selected patients at risk for sudden cardiac death (SCD).
ObjectiveThe aim of this single-center study was to assess clinical outcomes of S-ICD and single-chamber transvenous (TV)-ICD in an all-comers population.
MethodsThe study cohort comprised a total of 119 ICD patients who underwent either S-ICD (n = 35) or TV-ICD (n = 84) implantation at the University Hospital Frankfurt from 2009 to 2017.
By applying an inverse probability-weighting (IPW) analysis based on the propensity score including the Charlson Comorbidity Index (CCI) to adjust for potential extracardiac comorbidities, we aimed for head-to-head comparison on the study composite endpoint: overall survival, hospitalization, and device-associated events (including appropriate and inappropriate shocks or system-related complications).
ResultsThe median age of the study population was 66.
0 years, 22.
7% of the patients were female.
The underlying heart disease was ischemic cardiomyopathy (61.
4%) with a median LVEF of 30%.
Only 52.
9% had received an ICD for primary prevention, most of the patients (67.
3%) had advanced heart failure (NYHA class II–III) and 16.
8% were in atrial fibrillation.
CCI was 5 points in TV-ICD patients vs.
4 points for patients with S-ICD (p = 0.
209) indicating increased morbidity.
The composite endpoint occurred in 38 patients (31.
9 %), revealing no significant difference between patients implanted with an S-ICD or TV-ICD (unweighted HR 1.
50, 95 % confidence interval (CI) 0.
78–2.
90; p = 0.
229, weighted HR 0.
94, 95% CI, 0.
61–1.
50, p = 0.
777).
Furthermore, we observed no difference in any single clinical endpoint or device-associated outcome, neither in the unweighted cohort nor following inverse probability-weighting.
ConclusionClinical outcomes of the S-ICD and TV-ICD revealed no differences in the composite endpoint including survival, freedom of hospitalization and device-associated events, even after careful adjustment for potential confounders.
Moreover, the CCI was evaluated in a S-ICD cohort demonstrating higher survival rates than predicted by the CCI in young, polymorbid (S-)ICD patients.
Related Results
Abstract 9276: Subcutaneous and Transvenous Defibrillator in Arrhythmogenic Right Ventricular Cardiomyopathy
Abstract 9276: Subcutaneous and Transvenous Defibrillator in Arrhythmogenic Right Ventricular Cardiomyopathy
Introduction:
There is limited evidence guiding the selection between subcutaneous and transvenous ICD in patients with arrhythmogenic right ventricular cardiomyopathy ...
The effects of age on quality of life in implantable cardioverter defibrillator recipients
The effects of age on quality of life in implantable cardioverter defibrillator recipients
Background. The implantable cardioverter defibrillator shows superiority over conventional pharmacological therapy. The implantable cardioverter defibrillator has been implanted w...
Trends in Use and In-Hospital Outcomes of Subcutaneous Implantable Cardioverter Defibrillators in Patients Undergoing Long-Term Dialysis
Trends in Use and In-Hospital Outcomes of Subcutaneous Implantable Cardioverter Defibrillators in Patients Undergoing Long-Term Dialysis
Background and objectives
Patients on dialysis are at high risk of complications related to implantable cardioverter defibrillator (ICD) implantation; use of subcutaneo...
Autonomy on Trial
Autonomy on Trial
Photo by CHUTTERSNAP on Unsplash
Abstract
This paper critically examines how US bioethics and health law conceptualize patient autonomy, contrasting the rights-based, individualist...
Urrets-Zavalia syndrome following implantable collamer lens (ICL) implantation: a case report and review of the literature
Urrets-Zavalia syndrome following implantable collamer lens (ICL) implantation: a case report and review of the literature
Abstract
Background
Urrets-Zavalia syndrome is a condition that arises after eye surgery, often linked to increased intraocular pressure followin...
Small Cell Lung Cancer and Tarlatamab: A Meta-Analysis of Clinical Trials
Small Cell Lung Cancer and Tarlatamab: A Meta-Analysis of Clinical Trials
Abstract
Introduction
Tarlatamab is a Delta-like ligand 3 (DLL3) -directed bispecific T-cell engager recently approved for use in patients with advanced small cell lung cancer (SCL...
Endovascular Transvenous versus Open Femoropopliteal Bypass
Endovascular Transvenous versus Open Femoropopliteal Bypass
Background and Objectives: Lower extremity arterial disease is one of the most prevalent manifestations of atherosclerosis. The results from numerous studies regarding the best rev...
Pembrolizumab and Sarcoma: A meta-analysis
Pembrolizumab and Sarcoma: A meta-analysis
Abstract
Introduction: Pembrolizumab is a monoclonal antibody that promotes antitumor immunity. This study presents a systematic review and meta-analysis of the efficacy and safety...