When valve needs electrical wires - estimating pacemaker implantation after TAVR
View through CrossRef
Abstract
Introduction
Widespread availability and expanded indication of transcatheter aortic valve replacement (TAVR) modified paradigm of aortic stenosis. Despite elevated success rate, there are procedure related complications that need to be considered. One of the most frequent is conduction defects requiring permanent pacemaker (PPM) implantation resulting in prolonged hospital length of stay and hospitalization cost.
Several risk factors for PPM implantation after TAVI have been described, and, recently, the Emory Risk Score (ERS) was developed as a predictive tool for need of new PPM implantation post-TAVI in patients who implated a balloon-expandable valve.
Purpose
Our objective was to evaluate risk factors associated with PPM after TAVR and to validate the ERS in our population after implantation of balloon-expandable but also self-expanding valves.
Methods
Retrospective, observational and single center study involving patients submitted to TAVR between 2018 and 2021. Clinical, ECG data and procedure characteristics were obtained at time of TAVR and during follow-up.
The predictive discrimination of the scoring system for the risk for PPM placement after TAVR was evaluated using ROC curve analysis in SPSS Statistics. To estimate additional predictors of pacemaker implantation we used Cox proportional hazards regression models.
Results
From January 2018 to December 2021, 416 patients were referred to our centre for TAVR. The mean age was 82,5 ± 6,1 years, 55% female. Most frequently implanted valves were Evolut Pro and Sapien 3 ultra in 39,4% and 26,6% of pts, respectively. During follow-up 110pts (26%) needed device implantation (94 % double chamber pacemaker; 6% CRT-P or CRT-D), most frequently due to AV block.
On univariate analysis, QRS width was the only factor that showed a significant correlation with pacemaker implantation (HR 1,018, 95% CI 1,007-1028; p=0.027). We found no other clinical or procedural characteristics to be predictive of PM implantation.
ERS is composed of 4 variables – history of syncope, right complete branch block, QRS width > 140mseg and valve oversizing > 16% - and revealed a good sensitivity and specificity in estimating device implantation. We applied this score to our population and ROC curve analysis showed a significant prediction capacity (AUC 0,761 95% CI 0,699-0,822, p=0,031). This analysis was also performed analysing separately both subgroups of self-expandable valves (Medtronic Evolut and Evolut R) and balloon expandable valves (Edwards Sapiens). ROC curve analysis in both showed a good correlation with events – figure 1.
Conclusion
PM implantation is one of the most common complications following TAVR. In our population, the use of ERS displayed a very positive accuracy in predicting device implantation. Routine use of such tool can select patients at significant higher risk and thus best define patient allocation and resource utilization to reduce number of hospitalization days.
Title: When valve needs electrical wires - estimating pacemaker implantation after TAVR
Description:
Abstract
Introduction
Widespread availability and expanded indication of transcatheter aortic valve replacement (TAVR) modified paradigm of aortic stenosis.
Despite elevated success rate, there are procedure related complications that need to be considered.
One of the most frequent is conduction defects requiring permanent pacemaker (PPM) implantation resulting in prolonged hospital length of stay and hospitalization cost.
Several risk factors for PPM implantation after TAVI have been described, and, recently, the Emory Risk Score (ERS) was developed as a predictive tool for need of new PPM implantation post-TAVI in patients who implated a balloon-expandable valve.
Purpose
Our objective was to evaluate risk factors associated with PPM after TAVR and to validate the ERS in our population after implantation of balloon-expandable but also self-expanding valves.
Methods
Retrospective, observational and single center study involving patients submitted to TAVR between 2018 and 2021.
Clinical, ECG data and procedure characteristics were obtained at time of TAVR and during follow-up.
The predictive discrimination of the scoring system for the risk for PPM placement after TAVR was evaluated using ROC curve analysis in SPSS Statistics.
To estimate additional predictors of pacemaker implantation we used Cox proportional hazards regression models.
Results
From January 2018 to December 2021, 416 patients were referred to our centre for TAVR.
The mean age was 82,5 ± 6,1 years, 55% female.
Most frequently implanted valves were Evolut Pro and Sapien 3 ultra in 39,4% and 26,6% of pts, respectively.
During follow-up 110pts (26%) needed device implantation (94 % double chamber pacemaker; 6% CRT-P or CRT-D), most frequently due to AV block.
On univariate analysis, QRS width was the only factor that showed a significant correlation with pacemaker implantation (HR 1,018, 95% CI 1,007-1028; p=0.
027).
We found no other clinical or procedural characteristics to be predictive of PM implantation.
ERS is composed of 4 variables – history of syncope, right complete branch block, QRS width > 140mseg and valve oversizing > 16% - and revealed a good sensitivity and specificity in estimating device implantation.
We applied this score to our population and ROC curve analysis showed a significant prediction capacity (AUC 0,761 95% CI 0,699-0,822, p=0,031).
This analysis was also performed analysing separately both subgroups of self-expandable valves (Medtronic Evolut and Evolut R) and balloon expandable valves (Edwards Sapiens).
ROC curve analysis in both showed a good correlation with events – figure 1.
Conclusion
PM implantation is one of the most common complications following TAVR.
In our population, the use of ERS displayed a very positive accuracy in predicting device implantation.
Routine use of such tool can select patients at significant higher risk and thus best define patient allocation and resource utilization to reduce number of hospitalization days.
Related Results
Use of a wearable patch sensor for continuous activity and posture tracking to assess risk of early infection after transcatheter aortic valve replacement
Use of a wearable patch sensor for continuous activity and posture tracking to assess risk of early infection after transcatheter aortic valve replacement
Abstract
Background
Early infections after transcatheter aortic valve replacement (TAVR) represent one of the most common risk f...
Pacemaker implantation after balloon- or self-expandable transcatheter aortic valve replacement in patients with aortic stenosis
Pacemaker implantation after balloon- or self-expandable transcatheter aortic valve replacement in patients with aortic stenosis
Abstract
Background
The incidence of conduction abnormalities requiring permanent pacemaker implantation (PPI) after transcathet...
Abstract 4363465: Differential Outcomes of TAVR With and Without Percutaneous Coronary Intervention During Same Hospitalization
Abstract 4363465: Differential Outcomes of TAVR With and Without Percutaneous Coronary Intervention During Same Hospitalization
Background:
Transcatheter aortic valve replacement (TAVR) has emerged as a transformative, minimally invasive alternative to surgical aortic valve replacement f...
Pacemaker Implantation After Balloon‐ or Self‐Expandable Transcatheter Aortic Valve Replacement in Patients With Aortic Stenosis
Pacemaker Implantation After Balloon‐ or Self‐Expandable Transcatheter Aortic Valve Replacement in Patients With Aortic Stenosis
Background
The incidence of conduction abnormalities requiring permanent pacemaker implantation (
PPI
) after transcatheter a...
Outcomes of permanent pacemaker implantation following transcatheter aortic valve replacement
Outcomes of permanent pacemaker implantation following transcatheter aortic valve replacement
Abstract
Background
Conduction abnormalities leading to permanent pacemaker (PPM) implantation are common complications followin...
Abstract 14064: Echocardiographic Parameters Predicting Left Ventricular Ejection Fraction Improvement Following Transcatheter Aortic Valve Replacement
Abstract 14064: Echocardiographic Parameters Predicting Left Ventricular Ejection Fraction Improvement Following Transcatheter Aortic Valve Replacement
Introduction:
There is limited data available in terms of identifying echocardiographic parameters predicting improvement in left ventricular ejection fraction (LVEF) f...
Prognostic value of change in nutritional status after transcatheter aortic valve replacement
Prognostic value of change in nutritional status after transcatheter aortic valve replacement
Abstract
Introduction and purpose
Risk of malnutrition is a frequent condition among patients undergoing transcatheter aortic va...
Temporal trends in readmissions after transcatheter aortic valve replacement
Temporal trends in readmissions after transcatheter aortic valve replacement
Abstract
Background
Although readmissions after transcatheter aortic valve replacement (TAVR) were frequent in initial experienc...