Javascript must be enabled to continue!
Performance Analysis of SOFC / GT Combined Cycle System with Preheater in Front of Turbine
View through CrossRef
Abstract
Based on the SOFC zero-dimensional model, a SOFC turbine combined cycle simulation platform is established. For the SOFC/GT combined cycle system configuration scheme with the preheater placed in front of the turbine, the influence of cycle parameters on system performance is analyzed. The current density-power characteristic curves at different outlet pressures, the fuel flow-efficiency characteristic curve and the turbine inlet temperature curve at different fuel utilization rates were calculated and analyzed separately when different low-temperature and intermediate-temperature combined cycle system configurations were used. The results show that the low-temperature SOFC/GT cycle maintains high-efficiency design conditions with a fuel utilization rate of 0.8-0.85, and the highest efficiency is about 52%. The design working pressure of the medium temperature SOFC/GT cycle is suggested to be 0.4MPa-0.5MPa, and the system efficiency will be higher than 50% when the compression ratio is at 0.8-0.85, and the maximum efficiency is about 64%.
Title: Performance Analysis of SOFC / GT Combined Cycle System with Preheater in Front of Turbine
Description:
Abstract
Based on the SOFC zero-dimensional model, a SOFC turbine combined cycle simulation platform is established.
For the SOFC/GT combined cycle system configuration scheme with the preheater placed in front of the turbine, the influence of cycle parameters on system performance is analyzed.
The current density-power characteristic curves at different outlet pressures, the fuel flow-efficiency characteristic curve and the turbine inlet temperature curve at different fuel utilization rates were calculated and analyzed separately when different low-temperature and intermediate-temperature combined cycle system configurations were used.
The results show that the low-temperature SOFC/GT cycle maintains high-efficiency design conditions with a fuel utilization rate of 0.
8-0.
85, and the highest efficiency is about 52%.
The design working pressure of the medium temperature SOFC/GT cycle is suggested to be 0.
4MPa-0.
5MPa, and the system efficiency will be higher than 50% when the compression ratio is at 0.
8-0.
85, and the maximum efficiency is about 64%.
Related Results
Comparative Study on Performance of SOFC/GT and SOFC/SCO2 Turbine Combined Cycle System
Comparative Study on Performance of SOFC/GT and SOFC/SCO2 Turbine Combined Cycle System
Abstract
In order to compare and study the performance of SOFC/SCO2 cycle and SOFC/GT cycle, the efficiency of SOFC/GT cycle under the same working temperature and t...
A Solution for Improving Gas Turbine Performance Degradation and Emissions: The “GT Auto Tuner” Product
A Solution for Improving Gas Turbine Performance Degradation and Emissions: The “GT Auto Tuner” Product
Abstract
The main causes of gas turbine performance degradation in natural gas combined cycle power plants are corrosion, fouling, and high turbine inlet temperature...
Techno-Economic Analysis of Reversible and Paired Solid Oxide Cell Systems for Hydrogen Production
Techno-Economic Analysis of Reversible and Paired Solid Oxide Cell Systems for Hydrogen Production
The United States (U.S.) Department of Energy (DOE) National Energy Technology Laboratory (NETL) has been pursuing the development of solid oxide cell (SOC) technology to enable fu...
A 150Kw Integrated Solar Combined Cycle (ISCC) Power Plant
A 150Kw Integrated Solar Combined Cycle (ISCC) Power Plant
With the soaring price of oil and the global push toward reduction in carbon emissions, renewable energy is treated by many as a solution to the economic and environmental cost of ...
Impact of Individual High-Pressure Turbine Rotor Purge Flows on Turbine Center Frame Aerodynamics
Impact of Individual High-Pressure Turbine Rotor Purge Flows on Turbine Center Frame Aerodynamics
This paper presents an experimental study of the impact of individual high-pressure turbine purge flows on the main flow in a downstream turbine center frame duct. Measurements wer...
Development of Protonic Ceramic Conductors for SOFC and Sensor
Development of Protonic Ceramic Conductors for SOFC and Sensor
In recent years, commercialization of residential fuel cell "Ene-Farm" has begun in Japan, and SOFC using zirconia as electrolyte is also being introduced into the market. However,...
Peningkatan Prestasi Belajar Materi Bilangan Berpangkat Melalui Model Discovery Learning
Peningkatan Prestasi Belajar Materi Bilangan Berpangkat Melalui Model Discovery Learning
This research is motivated by the unoptimally the mastery of the material is still not optimal exponential number among learners and implementation Discovery learning in mathematic...
Effect of Blade Gap Ratio on Turbine Performance in Drag-Based Vertical-Axis Wind Turbines
Effect of Blade Gap Ratio on Turbine Performance in Drag-Based Vertical-Axis Wind Turbines
The aim of this study was to improve the performances of three-bladed vertical-axis wind turbines with gap distance. For this purpose, turbine design conditions such as a gap ratio...