Optimisasi dengan Audit Dosis Radiasi pada Pemeriksaan Thorak Proyeksi AP Pasien Dewasa

View through CrossRef
Optimization is one of the radiation protection efforts by giving radiation doses to patients as low as possible without reducing the quality of clinical images or what is often referred to as ALARA (As Low as Reasonably Achievable). A Diagnostic Reference Level (DRL) is an investigative indicator to optimize radiation protection for diagnostic and interventional radiology patients. The typical radiation dose value in AP thoracic examination patients at Gading Pluit Hospital is higher than the Indonesian DRL (I-DRL) value, so it is necessary to optimize the dose. Optimization of radiation dose aims to protect patients by evaluating exposure factors without compromising the quality of clinical images. AP chest image acquisition was performed using clinical exposure factors and their variations on the general radiographic X-Ray Listem REX 525-R. Evaluation of dose and image quality was carried out by a reading doctor/radiologist using a blind test. Optimizing results show that a lower exposure factor can reduce the radiation dose in AP thoracic examination of adult patients without affecting image quality. Exposure factor 80 kVp; 150 mA; 3.75 mAs is recommended to replace the exposure factor used before optimization, namely 80 kVp; 200 mA; 7 mAs. Keywords: optimization, DRL, radiation protection.
Title: Optimisasi dengan Audit Dosis Radiasi pada Pemeriksaan Thorak Proyeksi AP Pasien Dewasa
Description:
Optimization is one of the radiation protection efforts by giving radiation doses to patients as low as possible without reducing the quality of clinical images or what is often referred to as ALARA (As Low as Reasonably Achievable).
A Diagnostic Reference Level (DRL) is an investigative indicator to optimize radiation protection for diagnostic and interventional radiology patients.
The typical radiation dose value in AP thoracic examination patients at Gading Pluit Hospital is higher than the Indonesian DRL (I-DRL) value, so it is necessary to optimize the dose.
Optimization of radiation dose aims to protect patients by evaluating exposure factors without compromising the quality of clinical images.
AP chest image acquisition was performed using clinical exposure factors and their variations on the general radiographic X-Ray Listem REX 525-R.
Evaluation of dose and image quality was carried out by a reading doctor/radiologist using a blind test.
Optimizing results show that a lower exposure factor can reduce the radiation dose in AP thoracic examination of adult patients without affecting image quality.
Exposure factor 80 kVp; 150 mA; 3.
75 mAs is recommended to replace the exposure factor used before optimization, namely 80 kVp; 200 mA; 7 mAs.
Keywords: optimization, DRL, radiation protection.

Related Results

FAKTOR-FAKTOR YANG MEMPENGARUHI MORTALITAS PADA PASIEN DENGAN FRAKTUR COSTA: Literature Review
FAKTOR-FAKTOR YANG MEMPENGARUHI MORTALITAS PADA PASIEN DENGAN FRAKTUR COSTA: Literature Review
FAKTOR-FAKTOR YANG MEMPENGARUHI MORTALITAS PADA PASIEN DENGAN FRAKTUR COSTA: Literature  Review Anna Tri Wahyuni1), Masfuri2),  Liya Arista3)1,2,3 Fakultas Ilmu Keperawatan Univers...
Verifikasi Dosis Radiasi Teknik Penyinaran 3D-CRT pada Pasien Kanker Payudara Menggunakan Film EBT3 di Rumah Sakit UNAND
Verifikasi Dosis Radiasi Teknik Penyinaran 3D-CRT pada Pasien Kanker Payudara Menggunakan Film EBT3 di Rumah Sakit UNAND
Verifikasi dosis radiasi teknik penyinaran Three-Dimensional Conformal Radiation Therapy  (3D-CRT) pada pasien kanker payudara telah dilakukan menggunakan film EBT3. Verifikasi do...
STUDI ANALISIS AUDIT PAPARAN MEDIK SEBAGAI UPAYA OPTIMISASI PADA CT HEAD DI RUMAH SAKIT UMUM ELISABET MEDAN
STUDI ANALISIS AUDIT PAPARAN MEDIK SEBAGAI UPAYA OPTIMISASI PADA CT HEAD DI RUMAH SAKIT UMUM ELISABET MEDAN
Studi analisis audit paparan medik sebagai upaya optimisasi pada CT HEAD di Rumah Sakit Umum Elisabet Medan. Audit dosis dilakukan pada pemeriksaan CT scan melalui metrik dosis, un...
Evaluasi Penerapan Proteksi Radiasi pada Pekerja Radiasi di Instalasi Radiologi RS Naili DBS, RS Selaguri, dan RS UNAND
Evaluasi Penerapan Proteksi Radiasi pada Pekerja Radiasi di Instalasi Radiologi RS Naili DBS, RS Selaguri, dan RS UNAND
Telah dilakukan penelitian tentang penerapan proteksi radiasi pada pekerja radiasi di Instalasi Radiologi RS Naili DBS, RS Selaguri dan RS UNAND.  Penelitian bertujuan untuk menge...
PENERAPAN EDUKASI DAN KOMUNIKASI PASIEN MENGENAI DOSIS RADIASI SEBAGAI PENGEMBANGAN TINGKAT PANDUAN DIAGNOSTIK LOKAL
PENERAPAN EDUKASI DAN KOMUNIKASI PASIEN MENGENAI DOSIS RADIASI SEBAGAI PENGEMBANGAN TINGKAT PANDUAN DIAGNOSTIK LOKAL
Pemantauan dosis radiasi pada pasien merupakan aspek penting dalam upaya optimisasi proteksi radiasi. Penelitian ini bertujuan untuk menerapkan edukasi dan komunikasi pasien mengen...
OPTIMISASI PARAMETER SCAN PADA CT SCAN KEPALA NONKONTRAS DI INSTALASI RADIOLOGI RSUD PROF DR MARGONO SOEKARJO
OPTIMISASI PARAMETER SCAN PADA CT SCAN KEPALA NONKONTRAS DI INSTALASI RADIOLOGI RSUD PROF DR MARGONO SOEKARJO
Faktor eksposi yang sangat mempengaruhi dosis radiasi dan kualitas citra pada pemeriksaan CT Scan diantaranya tegangan (kV), kuat arus (mA) dan waktu pemindaian citra (s). Tegangan...
Paper K-9 Pelaporan Hasil Audit dan Tindak Lanjut Audit Internal
Paper K-9 Pelaporan Hasil Audit dan Tindak Lanjut Audit Internal
Pelaporan hasil audit merupakan komponen utama dalam komunikasi dari audit internal tentang hasil audit. Untuk mengkomunikasikan hasil audit diperlukan susunan laporan, dimana hasi...
Penerapan Optimisasi Paparan Medik CT-Scan Melalui Tingkat Panduan Diagnostik di RSUP dr. Soeradji Tirtonegoro
Penerapan Optimisasi Paparan Medik CT-Scan Melalui Tingkat Panduan Diagnostik di RSUP dr. Soeradji Tirtonegoro
Latar belakang: Pemanfaatan CT-Scan di RSUP dr. Soeradji Tirtonegoro menunjukkan adanya peningkatan yang signifikan, pemanfaatan tersebut harus dilakukan pengawasan untuk menjamin ...