Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Use of a wearable patch sensor for continuous activity and posture tracking to assess risk of early infection after transcatheter aortic valve replacement

View through CrossRef
Abstract Background Early infections after transcatheter aortic valve replacement (TAVR) represent one of the most common risk factors for non-cardiac 30-day mortality. Several wearable devices have been developed to measure vital signs and physical activity in real time while allowing full mobilization of the patient. However, their use has not been evaluated in a clinical setting with patients undergoing TAVR yet. Purpose We aimed to evaluate the feasibility of wearable patch sensors in assessing vital signs and daily activity before and after TAVR to predict an increased risk of early infections following TAVR. Methods Patients at high risk for infection undergoing transfemoral TAVR under local anesthesia were enrolled between September 2022 and January 2023. Postprocedural early infections were assessed, defined as C-reactive protein rise within 5 days after the procedure inducing antibiotic treatment. Vital signs (heart rate, respiratory rate, single-lead ECG) and activity (steps, posture) were monitored by a wearable patch sensor two days before (pre-TAVR) and two days after TAVR (post-TAVR). Results 54 patients completed 5 days of in-hospital monitoring with wearable patch sensors. The mean age was 80.3+5.2 years, 31 patients (57.4%) were male. Early infections occurred in 8 of 54 (14.8%) high-risk patients, of whom one was a urinary tract, one a pulmonary, and two access site-related etiology. Four infections remained with unknown focus. Respiratory rate was generally higher in patients developing an early infection after TAVR in both time periods, before (early infection 22±3 vs. no infection 18±2 bpm; p=0.001) and after TAVR (early infection 24±3 vs. no infection 19±3 bpm; p<0.001). Early infections were more prevalent in patients who showed less activity in the two days before TAVR regarding lower step count (early infection 242±360 vs. no infection 515±566; p=0.048) and high percentage of lying position during the whole day (early infection 89±12% vs. no infection 64±23%; p=0.071). Two days after TAVR, there were no significant differences in activity levels between both cohorts. Physical activity was reduced in both groups compared to the two days before TAVR, resulting in a reduced number of steps (pre-TAVR 473±546 vs. post-TAVR 267±434; p=0.039) and more daytime spent in lying position (pre-TAVR 57±19% vs. post-TAVR 73±24%; p<0.0001). Conclusion Wearable patch sensors are feasible to track vital signs and physical activity during hospital stay with promising opportunity for improving clinical management in TAVR patients. Early infections after TAVR are associated with decreased preprocedural mobility in high-risk patients. Therefore, these patients may be prematurely detected using wireless respiratory rate monitoring and infections prevented by intensified physiotherapy.
Title: Use of a wearable patch sensor for continuous activity and posture tracking to assess risk of early infection after transcatheter aortic valve replacement
Description:
Abstract Background Early infections after transcatheter aortic valve replacement (TAVR) represent one of the most common risk factors for non-cardiac 30-day mortality.
Several wearable devices have been developed to measure vital signs and physical activity in real time while allowing full mobilization of the patient.
However, their use has not been evaluated in a clinical setting with patients undergoing TAVR yet.
Purpose We aimed to evaluate the feasibility of wearable patch sensors in assessing vital signs and daily activity before and after TAVR to predict an increased risk of early infections following TAVR.
Methods Patients at high risk for infection undergoing transfemoral TAVR under local anesthesia were enrolled between September 2022 and January 2023.
Postprocedural early infections were assessed, defined as C-reactive protein rise within 5 days after the procedure inducing antibiotic treatment.
Vital signs (heart rate, respiratory rate, single-lead ECG) and activity (steps, posture) were monitored by a wearable patch sensor two days before (pre-TAVR) and two days after TAVR (post-TAVR).
Results 54 patients completed 5 days of in-hospital monitoring with wearable patch sensors.
The mean age was 80.
3+5.
2 years, 31 patients (57.
4%) were male.
Early infections occurred in 8 of 54 (14.
8%) high-risk patients, of whom one was a urinary tract, one a pulmonary, and two access site-related etiology.
Four infections remained with unknown focus.
Respiratory rate was generally higher in patients developing an early infection after TAVR in both time periods, before (early infection 22±3 vs.
no infection 18±2 bpm; p=0.
001) and after TAVR (early infection 24±3 vs.
no infection 19±3 bpm; p<0.
001).
Early infections were more prevalent in patients who showed less activity in the two days before TAVR regarding lower step count (early infection 242±360 vs.
no infection 515±566; p=0.
048) and high percentage of lying position during the whole day (early infection 89±12% vs.
no infection 64±23%; p=0.
071).
Two days after TAVR, there were no significant differences in activity levels between both cohorts.
Physical activity was reduced in both groups compared to the two days before TAVR, resulting in a reduced number of steps (pre-TAVR 473±546 vs.
post-TAVR 267±434; p=0.
039) and more daytime spent in lying position (pre-TAVR 57±19% vs.
post-TAVR 73±24%; p<0.
0001).
Conclusion Wearable patch sensors are feasible to track vital signs and physical activity during hospital stay with promising opportunity for improving clinical management in TAVR patients.
Early infections after TAVR are associated with decreased preprocedural mobility in high-risk patients.
Therefore, these patients may be prematurely detected using wireless respiratory rate monitoring and infections prevented by intensified physiotherapy.

Related Results

AORTIC ROOT ANEURYSM OR ECTASIA TREATED WITH AORTIC ROOT WRAPPED PROCEDURE
AORTIC ROOT ANEURYSM OR ECTASIA TREATED WITH AORTIC ROOT WRAPPED PROCEDURE
Objectives To develop a relatively simple and effective and less risk operation, aortic root wrapped procedure, to treat with aortic root aneurysm or ectasia. ...
Valve-Sparing Aortic Root Replacement by Congenital Heart Surgeons: A Single Center Experience.
Valve-Sparing Aortic Root Replacement by Congenital Heart Surgeons: A Single Center Experience.
Background Aortic root dilatation and aortic insufficiency can occur in patients with prior conotruncal defect surgery, the Ross procedure, and connective tissue disease (CTD). Val...
Evaluating the Science to Inform the Physical Activity Guidelines for Americans Midcourse Report
Evaluating the Science to Inform the Physical Activity Guidelines for Americans Midcourse Report
Abstract The Physical Activity Guidelines for Americans (Guidelines) advises older adults to be as active as possible. Yet, despite the well documented benefits of physical a...
Dynamic stochastic modeling for inertial sensors
Dynamic stochastic modeling for inertial sensors
Es ampliamente conocido que los modelos de error para sensores inerciales tienen dos componentes: El primero es un componente determinista que normalmente es calibrado por el fabri...
Infective endocarditis of quadricuspid aortic valve
Infective endocarditis of quadricuspid aortic valve
Abstract Background Infective endocarditis of the aortic valve is a relatively common disease presentation, with surgical intervention a mainstay of...
Transcatheter Aortic Valve Implantation in Bicuspid Aortic Valve Pathology: Current Evidence and Technical Challenges
Transcatheter Aortic Valve Implantation in Bicuspid Aortic Valve Pathology: Current Evidence and Technical Challenges
Transcatheter aortic valve implantation (TAVI) is an established therapy for severe symptomatic aortic valve stenosis (AS) in patients at high and intermediate risk for surgical ao...
P1716 Aorto-left atrial fistula with left atrium dissection
P1716 Aorto-left atrial fistula with left atrium dissection
Abstract We report a 71 year-old female with a history of rheumatic valvulopathy, who underwent St. Jude 23 and St. Jude 21 in ...

Back to Top