Javascript must be enabled to continue!
Ultraviolet Spectrophotometric Method for Ronnel in Feeds
View through CrossRef
Abstract
The ultraviolet spectrophotometric method for ronnel in feeds, adopted as official, first action at the 78th Annual Meeting (1964), was studied at levels of 0.015–5.5% ronnel by 9 collaborators on 4 feed samples. The study was to confirm the 1964 work and to test the accuracy and reproducibility of a Dowex 2-X8 ion exchange resin separation of ronnel from its decomposition product, 2,4,5-trichlorophenol. When an aliquot of the extract was passed through the Dowex column, 2,4,5-TCP remained, while ronnel passed through. Collaborators obtained satisfactory results; therefore, the Associate Referee recommends adoption of the new method and repeal of the earlier method.
Title: Ultraviolet Spectrophotometric Method for Ronnel in Feeds
Description:
Abstract
The ultraviolet spectrophotometric method for ronnel in feeds, adopted as official, first action at the 78th Annual Meeting (1964), was studied at levels of 0.
015–5.
5% ronnel by 9 collaborators on 4 feed samples.
The study was to confirm the 1964 work and to test the accuracy and reproducibility of a Dowex 2-X8 ion exchange resin separation of ronnel from its decomposition product, 2,4,5-trichlorophenol.
When an aliquot of the extract was passed through the Dowex column, 2,4,5-TCP remained, while ronnel passed through.
Collaborators obtained satisfactory results; therefore, the Associate Referee recommends adoption of the new method and repeal of the earlier method.
Related Results
Methods for Determining Ronnel in Feeds and Mineral Mixtures
Methods for Determining Ronnel in Feeds and Mineral Mixtures
Abstract
The official first action GLC method (electron capture detector) for ronnel in feeds, 38.126–38.129, is rapid and dependable but has been found to give low ...
Collaborative Study of Methods for Determination of Ronnel in Feeds and Mineral Mixtures
Collaborative Study of Methods for Determination of Ronnel in Feeds and Mineral Mixtures
Abstract
A GLC method (electron capture detector) for ronnel in cattle feeds at the 0.040% level and a UV method for ronnel in mineral mixtures (1–40% ronnel) were s...
Ultraviolet Spectrophotometric and Gas Chromatographic
Methods for Ronnel in Feeds
Ultraviolet Spectrophotometric and Gas Chromatographic
Methods for Ronnel in Feeds
Abstract
Two new methods for ronnel in feeds at levels of 0.035-0.60% ronnel were developed and studied by 10 collaborators. Methods involve extraction of the sample...
Ultraviolet Spectrophotometric Method for Ronnel in Feeds
Ultraviolet Spectrophotometric Method for Ronnel in Feeds
Abstract
The ultraviolet spectrophotometric method for Ronnel in feed mixtures, presented at the 1963 AOAC meeting, was studied further at levels of 0.015–0.6% Ronne...
Collaborative Study of a Gas Chromatographic Method for Ronnel in Feeds
Collaborative Study of a Gas Chromatographic Method for Ronnel in Feeds
Abstract
A GLC method (flame ionization detector) for ronnel in cattle feeds at levels of 0.038, 0.041, and 0.055% was studied by 11 collaborators. The method involv...
MON-015 Two Cases of Potential Oral Desmopressin Malabsorption Secondary to Concurrent Tube Feeds Administration in Patients with AVP-D (Arginine Vasopressin Deficiency)
MON-015 Two Cases of Potential Oral Desmopressin Malabsorption Secondary to Concurrent Tube Feeds Administration in Patients with AVP-D (Arginine Vasopressin Deficiency)
Abstract
Disclosure: G. Arora: None. V. Perugu: None. A.T. Drincic: None.
Introduction: AVP-D is an endocrine disorder characterized by non-osmo...
In Vitro Digestibility and Fermentation Kinetics of Agricultural By-product used as feed for Sheep in Trinidad, West Indies
In Vitro Digestibility and Fermentation Kinetics of Agricultural By-product used as feed for Sheep in Trinidad, West Indies
Abstract
The objective of this study was to determine the in vitro digestibility and gas production of agro-industrial by-products fed to sheep. This was done to determine ...
Residues in tissues of sheep following oral dosing and tip spraying with
32
p‐labelled ronnel
Residues in tissues of sheep following oral dosing and tip spraying with
32
p‐labelled ronnel
Abstract
Following oral dosing at a rate of 100 mg/kg live weight, ronnel appeared rapidly in the blood of sheep. The highest concentrations found were attained f...

