Javascript must be enabled to continue!
Permanent Pacemaker Implantation after TAVR – Predictors and Impact on Outcomes
View through CrossRef
The number of patients undergoing transcatheter aortic valve replacement (TAVR) worldwide is increasing steadily. Atrioventricular conduction disturbances, with or without the need for permanent pacemaker (PPM) implantation, are one of the most common adverse events after TAVR. Among transcatheter heart valves (THV), rates of conduction abnormalities vary from less than 10 % to more than 50 %. Depending on the reported data referred to, historical data showed that up to one-third of the patients required implantation of a PPM following TAVR. Although generally considered as a minor complication, PPM may have a profound impact on prognosis and quality of life after TAVR. Current data support the hypothesis that conduction abnormalities leading to pacemaker dependency result from mechanical compression of the conduction system by the prosthesis stent frame and individual predisposing conduction defects such as right bundle-branch block (RBBB). With several large randomised trials and registry studies having been published recently and second generation THV having been introduced, the debate about predictors for pacemaker implantation and their impact on outcome after TAVR is still ongoing.
Radcliffe Medical Media Ltd
Title: Permanent Pacemaker Implantation after TAVR – Predictors and Impact on Outcomes
Description:
The number of patients undergoing transcatheter aortic valve replacement (TAVR) worldwide is increasing steadily.
Atrioventricular conduction disturbances, with or without the need for permanent pacemaker (PPM) implantation, are one of the most common adverse events after TAVR.
Among transcatheter heart valves (THV), rates of conduction abnormalities vary from less than 10 % to more than 50 %.
Depending on the reported data referred to, historical data showed that up to one-third of the patients required implantation of a PPM following TAVR.
Although generally considered as a minor complication, PPM may have a profound impact on prognosis and quality of life after TAVR.
Current data support the hypothesis that conduction abnormalities leading to pacemaker dependency result from mechanical compression of the conduction system by the prosthesis stent frame and individual predisposing conduction defects such as right bundle-branch block (RBBB).
With several large randomised trials and registry studies having been published recently and second generation THV having been introduced, the debate about predictors for pacemaker implantation and their impact on outcome after TAVR is still ongoing.
Related Results
Use of a wearable patch sensor for continuous activity and posture tracking to assess risk of early infection after transcatheter aortic valve replacement
Use of a wearable patch sensor for continuous activity and posture tracking to assess risk of early infection after transcatheter aortic valve replacement
Abstract
Background
Early infections after transcatheter aortic valve replacement (TAVR) represent one of the most common risk f...
When valve needs electrical wires - estimating pacemaker implantation after TAVR
When valve needs electrical wires - estimating pacemaker implantation after TAVR
Abstract
Introduction
Widespread availability and expanded indication of transcatheter aortic valve replacement (TAVR) modified ...
Temporal trends in readmissions after transcatheter aortic valve replacement
Temporal trends in readmissions after transcatheter aortic valve replacement
Abstract
Background
Although readmissions after transcatheter aortic valve replacement (TAVR) were frequent in initial experienc...
Elevated high-sensitivity troponin T levels at 1-year follow-up are associated with increased long-term mortality after TAVR
Elevated high-sensitivity troponin T levels at 1-year follow-up are associated with increased long-term mortality after TAVR
Abstract
Background
Elevated pre-procedural high-sensitivity troponin T (hs-TnT) levels predict adverse outcomes in patients with severe aortic sten...
Abstract 4136085: The Prognostic Impact of Thrombocytopenia at 6 months after Transcatheter Aortic Valve Replacement: A Retrospective Multicenter Study
Abstract 4136085: The Prognostic Impact of Thrombocytopenia at 6 months after Transcatheter Aortic Valve Replacement: A Retrospective Multicenter Study
Background:
Transient thrombocytopenia after transcatheter aortic valve replacement (TAVR) is a common phenomenon. Thrombocytopenia after TAVR during the perioperative ...
P425Single procedure pace and ablate. evaluation of efficacy and safety comparing three different vascular routes
P425Single procedure pace and ablate. evaluation of efficacy and safety comparing three different vascular routes
Abstract
Funding Acknowledgements
No financial support for this study
Introduc...
Clinical Implications of Changes in Respiratory Instability Following Transcatheter Aortic Valve Replacement
Clinical Implications of Changes in Respiratory Instability Following Transcatheter Aortic Valve Replacement
Background: Respiratory instability, which can be quantified using respiratory stability time (RST), is associated with the severity and prognostic impact of the disease in patient...
Abstract 13908: Prevalence and Implications of Junctional Rhythm During Transcatheter Aortic Valve Replacement
Abstract 13908: Prevalence and Implications of Junctional Rhythm During Transcatheter Aortic Valve Replacement
Introduction:
Cardiac conduction abnormalities are among the most frequent complications of transcatheter aortic valve replacement (TAVR). A small case series has raise...

