Finite element analysis of deterioration of axial compression behavior of corroded steel-reinforced concrete middle-length columns

View through CrossRef
Abstract The corrosion problem of steel-reinforced concrete (SRC) columns in coastal areas is becoming increasingly severe and needs to be solved urgently. This study established a numerical analysis model for SRC middle-length columns considering corrosion effects. The bond–slip constitutive relationship between corroded steel and concrete was established. It was found that when the rust rate is low, the bonding stress of SRC columns is slightly increased compared to those without corrosion. The ultimate and residual bonding stress will decrease significantly when the rust rate exceeds 1.5%. The comparison between the numerical analysis model and the experimental results shows that the establishment of the model is reasonable. Subsequent parameter analysis showed that for corroded SRC mid-length columns, the larger the slenderness ratio of the component, the faster the decrease in axial compression performance. The rust rate increased from 0 to 30%, and the axial compression performance of SRC columns decreased significantly. When the rust rate exceeded 30%, the axial compression performance of concrete columns tended to stabilize. A formula for calculating SRC middle-length columns’ ultimate bearing capacity considering corrosion effects has been proposed.
Title: Finite element analysis of deterioration of axial compression behavior of corroded steel-reinforced concrete middle-length columns
Description:
Abstract The corrosion problem of steel-reinforced concrete (SRC) columns in coastal areas is becoming increasingly severe and needs to be solved urgently.
This study established a numerical analysis model for SRC middle-length columns considering corrosion effects.
The bond–slip constitutive relationship between corroded steel and concrete was established.
It was found that when the rust rate is low, the bonding stress of SRC columns is slightly increased compared to those without corrosion.
The ultimate and residual bonding stress will decrease significantly when the rust rate exceeds 1.
5%.
The comparison between the numerical analysis model and the experimental results shows that the establishment of the model is reasonable.
Subsequent parameter analysis showed that for corroded SRC mid-length columns, the larger the slenderness ratio of the component, the faster the decrease in axial compression performance.
The rust rate increased from 0 to 30%, and the axial compression performance of SRC columns decreased significantly.
When the rust rate exceeded 30%, the axial compression performance of concrete columns tended to stabilize.
A formula for calculating SRC middle-length columns’ ultimate bearing capacity considering corrosion effects has been proposed.

Related Results

Strength analysis of concrete-encased cellular steel columns
Strength analysis of concrete-encased cellular steel columns
This research investigates the compression behavior of bare cellular steel columns and concrete-encased cellular steel (CECS) columns subjected to concentric and eccentric loadings...
Axial Compression Capacity of Concrete Columns Reinforced With Corrosion-Resistant Metallic Reinforcement
Axial Compression Capacity of Concrete Columns Reinforced With Corrosion-Resistant Metallic Reinforcement
Abstract Axial compression performance of concrete columns reinforced with 2304 duplex stainless bars and spirals, carbon steel bars and spirals, and 316L stainless steel c...
Axial Compression Capacity of Concrete Columns Reinforced with Corrosion-Resistant Metallic Reinforcement
Axial Compression Capacity of Concrete Columns Reinforced with Corrosion-Resistant Metallic Reinforcement
Abstract Axial compression performance of concrete columns reinforced with 2304 solid stainless bars and spirals, carbon steel bars and spirals, and 316L stainless steel cl...
Eyes of Aniso-Axial Length Individuals Share Generally Similar Corneal Biometrics with Normal Eyes in Cataract Population
Eyes of Aniso-Axial Length Individuals Share Generally Similar Corneal Biometrics with Normal Eyes in Cataract Population
Aims. To determine the characteristics of corneal biometrics in eyes from aniso-axial length cataract patients compared with eyes from non-aniso-axial length individuals. Methods. ...
Rubberized reinforced concrete columns under axial and cyclic loading
Rubberized reinforced concrete columns under axial and cyclic loading
The experimental study presented in this research was conducted to understand the performance of rubberized concrete columns under axial loads and numerically analyze the conduct o...
Axial Compression Behavior of Concrete-Encased CFST Columns
Axial Compression Behavior of Concrete-Encased CFST Columns
Composite construction known as concrete-encased CFST is an outer covering of concrete surrounding a steel tube filled with concrete. It is employed as a structural member in multi...
Bearing Capacity Model of Corroded RC Eccentric Compression Columns Based on Hermite Interpolation and Fourier Fitting
Bearing Capacity Model of Corroded RC Eccentric Compression Columns Based on Hermite Interpolation and Fourier Fitting
With an extension in service years, bridges inevitably suffer from performance deterioration. Columns are the main components of bridge structures, which support the superstructure...
Probability Distribution of Cross-sectional radius of Corroded Steel Bars in Concrete and Its application
Probability Distribution of Cross-sectional radius of Corroded Steel Bars in Concrete and Its application
The impress current method is applied to acquire corroded steel bars embedded in concrete, and three-dimensional(3D) laser scanning techniques are applied on corroded steel bars to...

Back to Top