Improvement in transfusion safety using a specially designed transfusion wristband

View through CrossRef
Fatal haemolytic transfusion reaction due to ABO incompatibility occurs mainly as a result of clerical error. A blood sample drawn from the wrong patient and labelled as another patient's will not be detected by the blood bank unless there is a previous ABO grouping result. We report here the detection of such clerical error by the use of a specially designed transfusion wristband. The wristband has the following special features: (i) once attached, it cannot be removed except by cutting; (ii) it has a pocket containing a transfusion label; (iii) a unique transfusion barcode is printed on each transfusion label and the corresponding wristband simultaneously by computer technology; (iv) a transfusion label removed from the wristband after attachment to the patient has a characteristic tear‐mark distinguishing it from one removed prior to attachment. The blood bank only accepted those specimens bearing the tear‐marked transfusion labels. All blood units for this patient were labelled with this unique transfusion code together with the patient's details. The nurses counter‐checked the transfusion code on the blood units against the transfusion code on the patient's transfusion wristband prior to transfusion. If the blood sample for compatibility testing was drawn from the ‘wrong’ patient, the intended patient either did not carry a wristband or the transfusion codes did not match at all.  Pretransfusion compatibility tests were performed on 2189 patient samples using this procedure. It was well accepted by both ward and blood bank staff. Two potential mismatched transfusions were avoided. These two clerical errors would not have been detected because neither patient had previous ABO grouping results.
Title: Improvement in transfusion safety using a specially designed transfusion wristband
Description:
Fatal haemolytic transfusion reaction due to ABO incompatibility occurs mainly as a result of clerical error.
A blood sample drawn from the wrong patient and labelled as another patient's will not be detected by the blood bank unless there is a previous ABO grouping result.
We report here the detection of such clerical error by the use of a specially designed transfusion wristband.
The wristband has the following special features: (i) once attached, it cannot be removed except by cutting; (ii) it has a pocket containing a transfusion label; (iii) a unique transfusion barcode is printed on each transfusion label and the corresponding wristband simultaneously by computer technology; (iv) a transfusion label removed from the wristband after attachment to the patient has a characteristic tear‐mark distinguishing it from one removed prior to attachment.
The blood bank only accepted those specimens bearing the tear‐marked transfusion labels.
All blood units for this patient were labelled with this unique transfusion code together with the patient's details.
The nurses counter‐checked the transfusion code on the blood units against the transfusion code on the patient's transfusion wristband prior to transfusion.
If the blood sample for compatibility testing was drawn from the ‘wrong’ patient, the intended patient either did not carry a wristband or the transfusion codes did not match at all.
 Pretransfusion compatibility tests were performed on 2189 patient samples using this procedure.
It was well accepted by both ward and blood bank staff.
Two potential mismatched transfusions were avoided.
These two clerical errors would not have been detected because neither patient had previous ABO grouping results.

Related Results

Guidelines for Transfusion: A Way to Decrease Transfusion
Guidelines for Transfusion: A Way to Decrease Transfusion
SUMMARYTransfusion practice must be audited to comply with regulatory and quality standards. The Joint Commission on the Accreditation of Healthcare Organizations requires evaluati...
Heart Rate Variability from Wearables: A Comparative Analysis Among Standard ECG, a Smart Shirt and a Wristband
Heart Rate Variability from Wearables: A Comparative Analysis Among Standard ECG, a Smart Shirt and a Wristband
Heart Rate Variability (HRV) derived from standard one-lead electrocardiography (ECG) was compared with HRV computed by a commercial ECG shirt and with the inter-beat-intervals (IB...
Safety and Efficacy of 14-Day Cold Stored Platelets in Reversing Effects of Aspirin
Safety and Efficacy of 14-Day Cold Stored Platelets in Reversing Effects of Aspirin
Abstract Background: Aspirin is an antiplatelet therapy used to reduce the risk of vascular occlusive events. However, this therapy is associated with an increased r...
Analysis of Risk Factors for Perioperative Transfusion in Hip Arthroplasty and Modeling of a Nomogram
Analysis of Risk Factors for Perioperative Transfusion in Hip Arthroplasty and Modeling of a Nomogram
AIM: To investigate the risk factors of perioperative transfusion in hip arthroplasty and to construct a nomogram model to predict the risk of transfusion. METHODS: A total of 120 ...
Evaluating Effects of Culture and Language on Safety
Evaluating Effects of Culture and Language on Safety
This paper (SPE 54448) was revised for publication from paper SPE 48891, prepared for the 1998 SPE International Conference and Exhibition held in Beijing, 2–6 November. Original m...
Factors Influencing Patient Safety Management Behaviors in Nursing Students
Factors Influencing Patient Safety Management Behaviors in Nursing Students
The objective of this study is to identify the critical thinking Disposition, problem-solving processes, safety motivation, patient safety management knowledge, attitudes towards p...
Restrictive Versus Liberal Transfusion Strategy in Extracorporeal Membrane Oxygenation
Restrictive Versus Liberal Transfusion Strategy in Extracorporeal Membrane Oxygenation
Abstract Background: To compare the clinical outcomes of patients requiring extracorporeal membrane oxygenation (ECMO) support who had a restrictive red cell transfusio...