Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

APMP key comparison of DC voltage at 1.018 V and 10 V

View through CrossRef
A key comparison of DC voltage at 1.018 V and 10 V has been conducted from 2009 to 2011 between APMP member laboratories and the BIPM. All participants' results (except one) are within the uncertainty of comparison reference value and also within the uncertainty of the CIPM key comparison reference value of the BIPM.EM-K11.3, approximately 0.08 μV/V for 10 V and 0.2 μV/V for 1.018 V (k=2). The result of the comparison is supposed to successfully provide participating laboratories with the opportunity to compare national standards within the region, and to support participants' entries in Appendix C of the Mutual Recognition Arrangement. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
Title: APMP key comparison of DC voltage at 1.018 V and 10 V
Description:
A key comparison of DC voltage at 1.
018 V and 10 V has been conducted from 2009 to 2011 between APMP member laboratories and the BIPM.
All participants' results (except one) are within the uncertainty of comparison reference value and also within the uncertainty of the CIPM key comparison reference value of the BIPM.
EM-K11.
3, approximately 0.
08 μV/V for 10 V and 0.
2 μV/V for 1.
018 V (k=2).
The result of the comparison is supposed to successfully provide participating laboratories with the opportunity to compare national standards within the region, and to support participants' entries in Appendix C of the Mutual Recognition Arrangement.
Main text To reach the main text of this paper, click on Final Report.
Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.
bipm.
org/.
The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

Related Results

Design and Simulation Converter with Buck-boost Converter as The Voltage Stabilizer
Design and Simulation Converter with Buck-boost Converter as The Voltage Stabilizer
Buck-boost Converter is the device with the function to convert DC Voltage input to the setpoint DC Voltage output. Buck-boost converter can be used for regulating unstable voltage...
Comparison of standards for the calibration of voltage, current and resistance meters
Comparison of standards for the calibration of voltage, current and resistance meters
The 14th Meeting of the APMP Technical Committee on Electricity and Magnetism, held on 5 December 2011 in Kobe, Japan, decided to hold a comparison of standards for the calibration...
Control and modulation of modular multilevel converters
Control and modulation of modular multilevel converters
The integration of renewable energy sources in the electrical grid is reducing our dependence on fossil fuels. However, to ensure feasibility and reliability of distributed energy ...
Index-based optimal DG allocation for voltage quality improvement in an unbalanced network
Index-based optimal DG allocation for voltage quality improvement in an unbalanced network
Voltage quality is a one of the major concerns in distribution systems. Distributed Generations (DGs) have the potential to improve voltage quality, if optimally planned and operat...
Dynamic Low Voltage Ride through Detection and Mitigation in Brushless Doubly Fed Induction Generators
Dynamic Low Voltage Ride through Detection and Mitigation in Brushless Doubly Fed Induction Generators
Brushless doubly-fed induction generators have higher reliability, making them an attractive choice for not only offshore applications but also for remote locations. These machines...
A Topology Identification Monitoring Terminal Based on the Pulse Current Characteristic Analysis
A Topology Identification Monitoring Terminal Based on the Pulse Current Characteristic Analysis
Abstract The low-voltage distribution network field wiring is very complicated and there are many changes in the relationship between households and changes, which b...
Experimental determination of practical peak voltage.
Experimental determination of practical peak voltage.
In diagnostic radiology the practical peak voltage was initially derived by postulating that, for a given combination of X-ray tube and contrast geometry, a constant X-ray tube vol...
Clustering Analysis of Voltage Sag Events Based on Waveform Matching
Clustering Analysis of Voltage Sag Events Based on Waveform Matching
Voltage sags are a serious problem within power supplies, which pose threats to both residential electricity and industrial manufacturing. Since any one sag may be recorded by mult...

Back to Top