Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Sensorless Control of Voltage Peaks in Class-E Single-Ended Resonant Inverter for Induction Heating Rice Cooker

View through CrossRef
Single-ended (SE) resonant inverters are widely used as power converters for high-pressure rice cooker induction, with 1200 V insulated-gate bipolar transistors (IGBTs) being used as switching devices for kW-class products. When voltage fluctuations occur at the input stage of an SE resonant inverter, the resonant voltage applied to the IGBT can be directly affected, potentially exceeding the breakdown voltage of the IGBT, resulting in its failure. Consequently, the resonant voltage should be limited to below a safety threshold—hardware resonant voltage limiting methods are generally used to do so. This paper proposes a sensorless resonant voltage control method that limits the increase in the resonant voltage caused by overvoltage or supply voltage fluctuations. By calculating and predicting the resonance voltage through the analysis of the resonance circuit, the resonance voltage is controlled not to exceed the breakdown voltage of the IGBT. The experimental results of a 1.35 kW SE resonant inverter for a high-pressure induction heating rice cooker were used to verify the validity of the proposed sensorless resonant voltage limiting method.
Title: Sensorless Control of Voltage Peaks in Class-E Single-Ended Resonant Inverter for Induction Heating Rice Cooker
Description:
Single-ended (SE) resonant inverters are widely used as power converters for high-pressure rice cooker induction, with 1200 V insulated-gate bipolar transistors (IGBTs) being used as switching devices for kW-class products.
When voltage fluctuations occur at the input stage of an SE resonant inverter, the resonant voltage applied to the IGBT can be directly affected, potentially exceeding the breakdown voltage of the IGBT, resulting in its failure.
Consequently, the resonant voltage should be limited to below a safety threshold—hardware resonant voltage limiting methods are generally used to do so.
This paper proposes a sensorless resonant voltage control method that limits the increase in the resonant voltage caused by overvoltage or supply voltage fluctuations.
By calculating and predicting the resonance voltage through the analysis of the resonance circuit, the resonance voltage is controlled not to exceed the breakdown voltage of the IGBT.
The experimental results of a 1.
35 kW SE resonant inverter for a high-pressure induction heating rice cooker were used to verify the validity of the proposed sensorless resonant voltage limiting method.

Related Results

Analisis Perbandingan Kadar Glukosa Beras Berdasarkan Cara Memasak
Analisis Perbandingan Kadar Glukosa Beras Berdasarkan Cara Memasak
Rice is the main staple food source in Indonesia with an annual consumption of 25.3 million metric tons. The processing method of rice into cooked rice can affect the glucose level...
SPECIFICATION FOR TESTING AUTOMOTIVE MINIATURE BULBS
SPECIFICATION FOR TESTING AUTOMOTIVE MINIATURE BULBS
<div class="section abstract"> <div class="htmlview paragraph">The procedures contained in this specification cover the laboratory testing of miniature incandescent b...
Residual characteristics of buprofezin during rice processing
Residual characteristics of buprofezin during rice processing
In this study, we aimed to analyze changes in the residual levels of buprofezin during milling, washing, cooking, and processing of rice to make porridge, rice ...
Control contributions to AC microgrid inverters
Control contributions to AC microgrid inverters
This thesis is focused on the microgrid control framework. Specifically, it is concentrated on alternative current microgrids. As a result of the author involvement in different in...
Real-time mode of operation data analysis to catch the thread-tip denotes the failure cause of the grid-tie PV central inverter
Real-time mode of operation data analysis to catch the thread-tip denotes the failure cause of the grid-tie PV central inverter
AbstractThe inverter is considered the core of the PV power plant. The inverter’s failure leads to generation loss and decreases plant availability. So, it is required to investiga...