Javascript must be enabled to continue!
PERBEDAAN INFORMASI CITRA DIAGNOSTIK ANTARA SEKUEN T2 TSE STIR DAN T2 TSE DIXON PADA PEMERIKSAAN MRI LUMBAL POTONGAN SAGITAL DENGAN KASUS RADICULOPATHY
View through CrossRef
Backgroud: T2 Weighted Image Turbo Spin Echo Short Tau Inversion Recovery (T2 TSE STIR) is a sequence to get the image pathologic which can reveal of tissue along surrounding pathology with fat suppresion technique. T2 Weighted Image Turbo Spin Echo Dixon is a sequence to get the image pathologic whic can reveal of tissue along surrounding pathology with fat and water suppresion technique. Based on observations at Dr. Hasan Sadikin Bandung Hospital, in the examination of MRI Lumbal using T2 TSE sequence with Dixon fat suppresion technique, while according to The American College of Radiology (2012), using STIR fat suppresion technique. The purpose of this research was to know the difference of information diagnostic image that is produced between T2 TSE STIR and T2 TSE Dixon sequences on the examination of MRI lumbal sagittal slice with Radiculopathy case.
Methods: This research of type is experiment. The study was conducted with a 1,5 Tesla MRI at Installation Radiology of General Hospital Dr. Hasan Sadikin Bandung. The research took from of the 22 images of MRI lumbal sagittal slice from T2 TSE STIR and T2 TSE Dixon sequences with Radiculopathy cases. Assesment of the image was done by two respondents and Kappa test was conducted. Furthermore, the results of respondents assessment was analyzed by Wilcoxon different test.
Results: The results showed that the research result Ho rejected and Ha accepted which mean there is a differences of information diagnostic image between T2 TSE STIR and T2 TSE Dixon sequences on the examination of MRI lumbal sagittal slices with Radiculopathy case with p value = 0,001 (p <0,05).
Conclusion: T2 Sequence TSE Dixon can produce MRI images with more specific and homogeneous fat suppresion, thus providing more informative diagnostic information than T2 TSE STIR sequences.
Perhimpunan Radiografer Indonesia
Title: PERBEDAAN INFORMASI CITRA DIAGNOSTIK ANTARA SEKUEN T2 TSE STIR DAN T2 TSE DIXON PADA PEMERIKSAAN MRI LUMBAL POTONGAN SAGITAL DENGAN KASUS RADICULOPATHY
Description:
Backgroud: T2 Weighted Image Turbo Spin Echo Short Tau Inversion Recovery (T2 TSE STIR) is a sequence to get the image pathologic which can reveal of tissue along surrounding pathology with fat suppresion technique.
T2 Weighted Image Turbo Spin Echo Dixon is a sequence to get the image pathologic whic can reveal of tissue along surrounding pathology with fat and water suppresion technique.
Based on observations at Dr.
Hasan Sadikin Bandung Hospital, in the examination of MRI Lumbal using T2 TSE sequence with Dixon fat suppresion technique, while according to The American College of Radiology (2012), using STIR fat suppresion technique.
The purpose of this research was to know the difference of information diagnostic image that is produced between T2 TSE STIR and T2 TSE Dixon sequences on the examination of MRI lumbal sagittal slice with Radiculopathy case.
Methods: This research of type is experiment.
The study was conducted with a 1,5 Tesla MRI at Installation Radiology of General Hospital Dr.
Hasan Sadikin Bandung.
The research took from of the 22 images of MRI lumbal sagittal slice from T2 TSE STIR and T2 TSE Dixon sequences with Radiculopathy cases.
Assesment of the image was done by two respondents and Kappa test was conducted.
Furthermore, the results of respondents assessment was analyzed by Wilcoxon different test.
Results: The results showed that the research result Ho rejected and Ha accepted which mean there is a differences of information diagnostic image between T2 TSE STIR and T2 TSE Dixon sequences on the examination of MRI lumbal sagittal slices with Radiculopathy case with p value = 0,001 (p <0,05).
Conclusion: T2 Sequence TSE Dixon can produce MRI images with more specific and homogeneous fat suppresion, thus providing more informative diagnostic information than T2 TSE STIR sequences.
Related Results
Hydatid Disease of The Brain Parenchyma: A Systematic Review
Hydatid Disease of The Brain Parenchyma: A Systematic Review
Abstarct
Introduction
Isolated brain hydatid disease (BHD) is an extremely rare form of echinococcosis. A prompt and timely diagnosis is a crucial step in disease management. This ...
INFORMASI CITRA MRI KNEE JOINT KASUS RUPTURE ACL SEKUEN PD FATSAT DAN DIXON
INFORMASI CITRA MRI KNEE JOINT KASUS RUPTURE ACL SEKUEN PD FATSAT DAN DIXON
Rupture Anterior Cruciate Ligament adalah kondisi dimana ligament pada sendi lutut mengalami robek, yang dapat disebabkan oleh trauma. Untuk mengoptimalkan anatomi dan patologi mak...
FAKTOR-FAKTOR YANG MEMPENGARUHI MORTALITAS PADA PASIEN DENGAN FRAKTUR COSTA: Literature Review
FAKTOR-FAKTOR YANG MEMPENGARUHI MORTALITAS PADA PASIEN DENGAN FRAKTUR COSTA: Literature Review
FAKTOR-FAKTOR YANG MEMPENGARUHI MORTALITAS PADA PASIEN DENGAN FRAKTUR COSTA: Literature Review Anna Tri Wahyuni1), Masfuri2), Liya Arista3)1,2,3 Fakultas Ilmu Keperawatan Univers...
Analisis Perbedaan Kualitas Citra Pemeriksaan MRI Cervical Potongan Sagital Pada Penggunaan Sekuens T2 Tse Dixon, T2 Tse Spair, Dan T2 Tse Stir
Analisis Perbedaan Kualitas Citra Pemeriksaan MRI Cervical Potongan Sagital Pada Penggunaan Sekuens T2 Tse Dixon, T2 Tse Spair, Dan T2 Tse Stir
Fat suppression merupakan teknik penting dalam pencitraan MRI, khususnya untuk meningkatkan visualisasi struktur anatomi dengan mengurangi sinyal lemak. Penelitian ini bertujuan un...
Optimalisasi pemeriksaan MRI lumbal pada kasus low back pain dengan protocol wholespine sequen T2 TSE sagital di Rumah Sakit Kasih Ibu Denpasar
Optimalisasi pemeriksaan MRI lumbal pada kasus low back pain dengan protocol wholespine sequen T2 TSE sagital di Rumah Sakit Kasih Ibu Denpasar
MRI memiliki peranan yang penting pada aplikasi sains biologis medis, karena MRI mampu menunjukkan gambaran shoft tissue tubuh dan proses metabolisme didalamnya. Tujuan dari peneli...
Perbedaan Informasi Citra Diagnostik T2WI Spir dan T2WI Dixon MRI Lumbal Potongan Sagital Dengan Kasus Hernia Nucleus Pulposus (HNP)
Perbedaan Informasi Citra Diagnostik T2WI Spir dan T2WI Dixon MRI Lumbal Potongan Sagital Dengan Kasus Hernia Nucleus Pulposus (HNP)
Herniated nucleus pulposus (HNP) is the leading cause of back pain in old age, occurring as a result of tearing of the fibrous annulus and the nucleus pulposus exiting through the ...
INFORMASI CITRA MRCP CORONAL T2 SSFSE DENGAN TEKNIK BREATH-HOLD DAN RESPIRATORY TRIGGERING PADA KASUS CHOLELITHIASIS
INFORMASI CITRA MRCP CORONAL T2 SSFSE DENGAN TEKNIK BREATH-HOLD DAN RESPIRATORY TRIGGERING PADA KASUS CHOLELITHIASIS
Penggunaan teknik breath-hold dan respiratory triggering dapat mencegah pergerakan pernapasan yang menyebabkan artefak pada hasil citra pemeriksaan Magnetic Resonance Cholangio Pan...