Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Axial Compression Capacity of Concrete Columns Reinforced with Corrosion-Resistant Metallic Reinforcement

View through CrossRef
Abstract Axial compression performance of concrete columns reinforced with 2304 solid stainless bars and spirals, carbon steel bars and spirals, and 316L stainless steel clad bars is examined after the columns are exposed to severe corrosion. Two groups of columns were investigated: a control group, and a group submerged in a 5.0% by weight chloride solution subjected to accelerated corrosion. A relatively high impressed current density of 8.5 μA/mm2 was used and after 60 days of accelerated corrosion the columns were tested to failure under axial compression. In terms of mass loss per unit of corrosion energy, columns reinforced with stainless steel spirals and either solid stainless or stainless clad vertical bars were 197% more corrosion resistant than carbon steel. Bars made with 2304 solid stainless steel and 316L stainless clad materials developed localized pitting corrosion that led to degradation of the concrete cover and a larger drop in axial compression than carbon steel reinforced columns. However, the carbon steel reinforced columns reached lower failure displacements and a corroded carbon steel reinforced column was the only column to experience sudden failure prior to reaching its theoretical maximum axial compression capacity. Axial compression capacity of the columns in both the control and corroded conditions was modeled using concrete confinement models that produced good agreement with the experimental results.
Springer Science and Business Media LLC
Title: Axial Compression Capacity of Concrete Columns Reinforced with Corrosion-Resistant Metallic Reinforcement
Description:
Abstract Axial compression performance of concrete columns reinforced with 2304 solid stainless bars and spirals, carbon steel bars and spirals, and 316L stainless steel clad bars is examined after the columns are exposed to severe corrosion.
Two groups of columns were investigated: a control group, and a group submerged in a 5.
0% by weight chloride solution subjected to accelerated corrosion.
A relatively high impressed current density of 8.
5 μA/mm2 was used and after 60 days of accelerated corrosion the columns were tested to failure under axial compression.
In terms of mass loss per unit of corrosion energy, columns reinforced with stainless steel spirals and either solid stainless or stainless clad vertical bars were 197% more corrosion resistant than carbon steel.
Bars made with 2304 solid stainless steel and 316L stainless clad materials developed localized pitting corrosion that led to degradation of the concrete cover and a larger drop in axial compression than carbon steel reinforced columns.
However, the carbon steel reinforced columns reached lower failure displacements and a corroded carbon steel reinforced column was the only column to experience sudden failure prior to reaching its theoretical maximum axial compression capacity.
Axial compression capacity of the columns in both the control and corroded conditions was modeled using concrete confinement models that produced good agreement with the experimental results.

Related Results

Axial Compression Capacity of Concrete Columns Reinforced With Corrosion-Resistant Metallic Reinforcement
Axial Compression Capacity of Concrete Columns Reinforced With Corrosion-Resistant Metallic Reinforcement
Abstract Axial compression performance of concrete columns reinforced with 2304 duplex stainless bars and spirals, carbon steel bars and spirals, and 316L stainless steel c...
The Effect of Compression Reinforcement on the Shear Behavior of Concrete Beams with Hybrid Reinforcement
The Effect of Compression Reinforcement on the Shear Behavior of Concrete Beams with Hybrid Reinforcement
Abstract This study examines the impact of steel compression reinforcement on the shear behavior of concrete beams reinforced with glass fiber reinforced polymer (GFRP) bar...
Enhancing structural behaviour of polypropylene fibre concrete columns longitudinally reinforced with fibreglass bars
Enhancing structural behaviour of polypropylene fibre concrete columns longitudinally reinforced with fibreglass bars
Abstract The research aims to study the behaviour of concrete columns reinforced with fibreglass as bars exposed to seawater. Firstly, hardened concrete properties a...
Improvement of Seismic Performance of Ordinary Reinforced Partially Grouted Concrete Masonry Shear Walls
Improvement of Seismic Performance of Ordinary Reinforced Partially Grouted Concrete Masonry Shear Walls
Reinforced masonry constitutes about 10% of all low-rise construction in the US. Most of these structures are commercial and school buildings. It may also be used for multi-story h...
Influence of axial compression ratio in building columns
Influence of axial compression ratio in building columns
(English) Axial forces in columns of moment-resisting frames (MRF) have a paramount role for the seismic performance of these structural systems. Nonetheless, there are significan...
Research progress and development direction of drability assessment methods for CFRP reinforced concrete structural members
Research progress and development direction of drability assessment methods for CFRP reinforced concrete structural members
Abstract The construction industry is an important part of China’s national economic development, in recent years with the economic development is to increase the in...

Back to Top