Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Analysis Of Voltage and Current Performance of 100 WP Solar Panel Using Matlab Simulink R2021a

View through CrossRef
The growing population increases the need for electrical energy. Development of renewable energy that is environmentally friendly and sustainable to replace fossil energy sources that are almost depleted and have an impact on global warming. Indonesia is on the equator where there is potential for the application of photovoltaic technology. However, the high cost of implementing a solar power system must be considered, as the energy supply is intermittent and highly dependent on environmental factors such as solar radiation and temperature. Therefore, it is necessary to design a solar power generation system using MATLAB Simulink 2021a software simulation method to avoid the implementation error rate and determine the success, especially the system performance. The MATLAB Simulink 2021a simulation method uses a 10 Wp monocrystalline Photovoltaic (PV) and a 12 V 20 Ah Lead-Acid battery. PV array design, PV Array, Buck Converter, Inverter, PV Controller, Battery Controller and Metering. To find out the value of the output voltage and current from solar panels, batteries, and the results of the DC to AC conversion by the inverter and using a load of 17 watts. The simulation results of a 100 Wp solar panel at MATLAB Simulink in the South Jakarta area with an intensity of 131W/m2 and a temperature of 27.99 °C produce a PV array output voltage and current of 17.6 V and 5.8 A, respectively. The battery voltage and current show the highest values are 12.58 V and 4.8 A. The actual voltage and current are close to the values of Vmp 17.8 V and Imp 5.2 A, so that the results of this system design can be stated to have maximum performance. Meanwhile, the inverter output has the highest voltage and current values of 218 V and 0.085 A.
Title: Analysis Of Voltage and Current Performance of 100 WP Solar Panel Using Matlab Simulink R2021a
Description:
The growing population increases the need for electrical energy.
Development of renewable energy that is environmentally friendly and sustainable to replace fossil energy sources that are almost depleted and have an impact on global warming.
Indonesia is on the equator where there is potential for the application of photovoltaic technology.
However, the high cost of implementing a solar power system must be considered, as the energy supply is intermittent and highly dependent on environmental factors such as solar radiation and temperature.
Therefore, it is necessary to design a solar power generation system using MATLAB Simulink 2021a software simulation method to avoid the implementation error rate and determine the success, especially the system performance.
The MATLAB Simulink 2021a simulation method uses a 10 Wp monocrystalline Photovoltaic (PV) and a 12 V 20 Ah Lead-Acid battery.
PV array design, PV Array, Buck Converter, Inverter, PV Controller, Battery Controller and Metering.
To find out the value of the output voltage and current from solar panels, batteries, and the results of the DC to AC conversion by the inverter and using a load of 17 watts.
The simulation results of a 100 Wp solar panel at MATLAB Simulink in the South Jakarta area with an intensity of 131W/m2 and a temperature of 27.
99 °C produce a PV array output voltage and current of 17.
6 V and 5.
8 A, respectively.
The battery voltage and current show the highest values are 12.
58 V and 4.
8 A.
The actual voltage and current are close to the values of Vmp 17.
8 V and Imp 5.
2 A, so that the results of this system design can be stated to have maximum performance.
Meanwhile, the inverter output has the highest voltage and current values of 218 V and 0.
085 A.

Related Results

Evolution of Antimicrobial Resistance in Community vs. Hospital-Acquired Infections
Evolution of Antimicrobial Resistance in Community vs. Hospital-Acquired Infections
Abstract Introduction Hospitals are high-risk environments for infections. Despite the global recognition of these pathogens, few studies compare microorganisms from community-acqu...
Solar Trackers Using Six-Bar Linkages
Solar Trackers Using Six-Bar Linkages
Abstract A solar panel faces the sun or has the solar ray normal to its face to enhance power reaping. A fixed solar panel can only meet this condition at one moment...
Control and modulation of modular multilevel converters
Control and modulation of modular multilevel converters
The integration of renewable energy sources in the electrical grid is reducing our dependence on fossil fuels. However, to ensure feasibility and reliability of distributed energy ...
Assessment of Chat-GPT, Gemini, and Perplexity in Principle of Research Publication: A Comparative Study
Assessment of Chat-GPT, Gemini, and Perplexity in Principle of Research Publication: A Comparative Study
Abstract Introduction Many researchers utilize artificial intelligence (AI) to aid their research endeavors. This study seeks to assess and contrast the performance of three sophis...
Effect of Power Characteristics on Solar Panels: Hands-On Projects for Clean Energy Systems Class
Effect of Power Characteristics on Solar Panels: Hands-On Projects for Clean Energy Systems Class
In this paper, experiments that can be introduced to Clean Energy Systems classes are described. The experiments investigate the effect of power characteristics (temperature, shade...
Enhancement Open Circuit Voltage of Calcium Titanate AR Coated Magnesium Solar Cell
Enhancement Open Circuit Voltage of Calcium Titanate AR Coated Magnesium Solar Cell
The present research aims to enhance the open circuit voltage of fabricated solar cell through Anti–Reflection (AR) coating on the cell substrate. Solar cell is fabricate using ITO...
ANALYSIS OF THE OPERATION MODE OF THE SOLAR POWER PLANT
ANALYSIS OF THE OPERATION MODE OF THE SOLAR POWER PLANT
The article examines the load change schedule of the solar power plant in the Ukraine-Moldova energy union. The analysis of data averaged at minute and 15-minute intervals in the p...
EPD Electronic Pathogen Detection v1
EPD Electronic Pathogen Detection v1
Electronic pathogen detection (EPD) is a non - invasive, rapid, affordable, point- of- care test, for Covid 19 resulting from infection with SARS-CoV-2 virus. EPD scanning techno...