Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Enhancement Open Circuit Voltage of Calcium Titanate AR Coated Magnesium Solar Cell

View through CrossRef
The present research aims to enhance the open circuit voltage of fabricated solar cell through Anti–Reflection (AR) coating on the cell substrate. Solar cell is fabricate using ITO Glass, titanium dioxide, magnesium and redox. Calcium Titanium Oxide (CaTiO3) is chosen as the AR coating material for constructing thin film layer on fabricated solar cell. Selected AR coating material have unique features such as orthorhombic, biaxial, non-radioactive and non-magnetic with electron bulk density of 3.91 g/cm3 respectively. Commonly, voltage generation of the multi crystalline solar cell is low (12% to 14%) due to much reflection of inward sun radiation. Deposition of AR coating on the substrate (fabricated solar cell) can minimize the reflection loss of sun radiation. The maximum improvement in solar cell efficiency after AR coating has been reported as 19.3%. Sputter coating technique is more favorable for thin film coating due to its salient features like uniform coating thickness controlled by time. This uniform coating thickness absorbs more sun radiation. Radio Frequency (RF) magnetron sputter coating technique is utilized in the current research to deposit CaTiO3 on solar cells. Prior to coating, the AR material is pelletized using Universal Testing Machine (UTM). The substrate are coated under varying time duration of 15-minutes, 30-minutes and 45-minutes in order to analyze the variation in open circuit voltage. The deposition of coating on the substrate are confirmed using SEM and FESEM. Open circuit voltage of controlled atmosphere studies for pure and AR coated solar cells (fabricated) are examined. Controlled atmosphere tests of AR coated thin films are conducted by placing the substrate inside a solar simulator and the solar simulator consist of IR thermometer (To measure Temperature), solar power meter (To measure Radiation) and multimeter (To measure Open circuit voltage). Neodym daylight lamp is used to control the radiation in solar simulator. The improvement in cell voltage proves that thin film AR coating considerably minimizes the reflective loss.
Title: Enhancement Open Circuit Voltage of Calcium Titanate AR Coated Magnesium Solar Cell
Description:
The present research aims to enhance the open circuit voltage of fabricated solar cell through Anti–Reflection (AR) coating on the cell substrate.
Solar cell is fabricate using ITO Glass, titanium dioxide, magnesium and redox.
Calcium Titanium Oxide (CaTiO3) is chosen as the AR coating material for constructing thin film layer on fabricated solar cell.
Selected AR coating material have unique features such as orthorhombic, biaxial, non-radioactive and non-magnetic with electron bulk density of 3.
91 g/cm3 respectively.
Commonly, voltage generation of the multi crystalline solar cell is low (12% to 14%) due to much reflection of inward sun radiation.
Deposition of AR coating on the substrate (fabricated solar cell) can minimize the reflection loss of sun radiation.
The maximum improvement in solar cell efficiency after AR coating has been reported as 19.
3%.
Sputter coating technique is more favorable for thin film coating due to its salient features like uniform coating thickness controlled by time.
This uniform coating thickness absorbs more sun radiation.
Radio Frequency (RF) magnetron sputter coating technique is utilized in the current research to deposit CaTiO3 on solar cells.
Prior to coating, the AR material is pelletized using Universal Testing Machine (UTM).
The substrate are coated under varying time duration of 15-minutes, 30-minutes and 45-minutes in order to analyze the variation in open circuit voltage.
The deposition of coating on the substrate are confirmed using SEM and FESEM.
Open circuit voltage of controlled atmosphere studies for pure and AR coated solar cells (fabricated) are examined.
Controlled atmosphere tests of AR coated thin films are conducted by placing the substrate inside a solar simulator and the solar simulator consist of IR thermometer (To measure Temperature), solar power meter (To measure Radiation) and multimeter (To measure Open circuit voltage).
Neodym daylight lamp is used to control the radiation in solar simulator.
The improvement in cell voltage proves that thin film AR coating considerably minimizes the reflective loss.

Related Results

[RETRACTED] Rhino XL Male Enhancement v1
[RETRACTED] Rhino XL Male Enhancement v1
[RETRACTED]Rhino XL Reviews, NY USA: Studies show that testosterone levels in males decrease constantly with growing age. There are also many other problems that males face due ...
Hydrothermal synthesis of titanate nanoroll from micron-sized titania power using sonication pretreatment
Hydrothermal synthesis of titanate nanoroll from micron-sized titania power using sonication pretreatment
Regarding to variation of size of TiO[subscript 2] powder (400 nm and 1 µm), reaction temperature (90-180 degree celsius ), and sonication power (0-38 W), morphology, length and ph...
Solar Trackers Using Six-Bar Linkages
Solar Trackers Using Six-Bar Linkages
Abstract A solar panel faces the sun or has the solar ray normal to its face to enhance power reaping. A fixed solar panel can only meet this condition at one moment...
Complex Collision Tumors: A Systematic Review
Complex Collision Tumors: A Systematic Review
Abstract Introduction: A collision tumor consists of two distinct neoplastic components located within the same organ, separated by stromal tissue, without histological intermixing...
Proposal Topologies of RF Rectifiers Using 65nm TSMC MOS Technology
Proposal Topologies of RF Rectifiers Using 65nm TSMC MOS Technology
Radio-Frequency Energy Harvesting (RFEH) can be considered a promising solution for powering devices in the Internet of Things era, such as low-power wireless sensors, since RF ele...
What is the Proper Composition of the Dialysate Magnesium and How Much Magnesium is Removed During Pre-Dilution Online Hemodiafiltration?
What is the Proper Composition of the Dialysate Magnesium and How Much Magnesium is Removed During Pre-Dilution Online Hemodiafiltration?
Aim: The aim of the study was to determine the ideal dialysate magnesium during hemodialysis, knowing that the solution used is not satisfactory and is often associated with low se...
Frequency of Common Chromosomal Abnormalities in Patients with Idiopathic Acquired Aplastic Anemia
Frequency of Common Chromosomal Abnormalities in Patients with Idiopathic Acquired Aplastic Anemia
Objective: To determine the frequency of common chromosomal aberrations in local population idiopathic determine the frequency of common chromosomal aberrations in local population...

Back to Top