Javascript must be enabled to continue!
Conceptual Framework for the Development of an Air Quality Monitoring Station in Denton, Texas
View through CrossRef
Denton, Texas consistently reaches ozone nonattainment levels. This has led to a large focus of air pollution monitoring efforts in the region, with long-range transport being explored as a key contributor. For this study, the University of North Texas Discovery Park campus was chosen as a prospective location for an extensive air quality monitoring station. Sixteen years of ozone and meteorological data for five state-run monitoring sites within a 25 mile radius, including the nearest Denton Airport site, was gathered from TCEQ online database for the month of April for the years 2000 to 2015. The data was analyzed to show a historical, regional perspective of ozone near the proposed site. The maximum ozone concentration measured at the Denton Airport location over the 16 year period was measured at 96 ppb in 2001. Experimental ozone and meteorological measurements were collected at the Discovery Park location from March 26 to April 3 and April 8 to April, 2016 and compared to the Denton Airport monitoring site. A time lag in ozone trends and an increase in peak ozone concentrations at the proposed location were observed at the proposed site in comparison to the Denton Airport site. Historical and experimental meteorological data agreed in indicating that southern winds that rarely exceed 20 miles per hour are the predominant wind pattern. Back trajectories, wind roses, pollution roses, and bivariate plots created for peak ozone days during experimental periods support long range transport as a considerable cause of high ozone levels in Denton. Furthermore, a study of the precursor characteristics at the Denton Airport site indicated the site was being affected by a local source of nitrogen dioxide that was not affecting the proposed location. The differences in the Denton Airport site and the proposed site indicate that further monitoring at Discovery Park would be insightful. An outline of an expansive mobile monitoring station and suggestions for effective utilization are provided to guide future studies in Denton and the surrounding North Texas region.
Title: Conceptual Framework for the Development of an Air Quality Monitoring Station in Denton, Texas
Description:
Denton, Texas consistently reaches ozone nonattainment levels.
This has led to a large focus of air pollution monitoring efforts in the region, with long-range transport being explored as a key contributor.
For this study, the University of North Texas Discovery Park campus was chosen as a prospective location for an extensive air quality monitoring station.
Sixteen years of ozone and meteorological data for five state-run monitoring sites within a 25 mile radius, including the nearest Denton Airport site, was gathered from TCEQ online database for the month of April for the years 2000 to 2015.
The data was analyzed to show a historical, regional perspective of ozone near the proposed site.
The maximum ozone concentration measured at the Denton Airport location over the 16 year period was measured at 96 ppb in 2001.
Experimental ozone and meteorological measurements were collected at the Discovery Park location from March 26 to April 3 and April 8 to April, 2016 and compared to the Denton Airport monitoring site.
A time lag in ozone trends and an increase in peak ozone concentrations at the proposed location were observed at the proposed site in comparison to the Denton Airport site.
Historical and experimental meteorological data agreed in indicating that southern winds that rarely exceed 20 miles per hour are the predominant wind pattern.
Back trajectories, wind roses, pollution roses, and bivariate plots created for peak ozone days during experimental periods support long range transport as a considerable cause of high ozone levels in Denton.
Furthermore, a study of the precursor characteristics at the Denton Airport site indicated the site was being affected by a local source of nitrogen dioxide that was not affecting the proposed location.
The differences in the Denton Airport site and the proposed site indicate that further monitoring at Discovery Park would be insightful.
An outline of an expansive mobile monitoring station and suggestions for effective utilization are provided to guide future studies in Denton and the surrounding North Texas region.
Related Results
Crafting Downtown Denton: An Exploration of Craft Beer Consumption as an Activity in Denton, Texas
Crafting Downtown Denton: An Exploration of Craft Beer Consumption as an Activity in Denton, Texas
Craft beer as a cultural phenomenon coincided with the revitalization of downtown Denton, Texas. Much of the existing literature on craft beer and its relation to place focuses on ...
Some Soundwalks (Denton, Tx)
Some Soundwalks (Denton, Tx)
some soundwalks (Denton, TX) is an audio portrait of the Denton square - the area in downtown Denton bordered by the streets Oak, Hickory, Elm, and Locust. For three months (June -...
Analysis of the Response Law of Station Buried Depth Change to Subway Station Under Vibration Load
Analysis of the Response Law of Station Buried Depth Change to Subway Station Under Vibration Load
In the period of rapid development of urban rail transit, the traditional transportation hub has become increasingly unable to meet the needs of people 's travel due to the lack of...
POTENSI INDIKATIF CADANGAN AIR TANAH DI KABUPATEN BANGLI
POTENSI INDIKATIF CADANGAN AIR TANAH DI KABUPATEN BANGLI
Wilayah pada Kabupaten Bangli merupakan kawasan kabupaten yang tanpa memiliki kawasan pantai serta sebagian besar wilayahnya berada pada daratan tinggi dan hanya sebagian kecil wil...
RANCANG BANGUN SISTEM PEMANTAUAN KONDISI AIR
RANCANG BANGUN SISTEM PEMANTAUAN KONDISI AIR
The limited number of water condition monitoring officers at the Bone Bolango PDAM water reservoir has caused many customer complaints about the turbidity and sometimes non-flowing...
SISTEM KRAN AIR OTOMATIS MENGGUNAKAN SENSOR INFRARED AJDUSTABLE
SISTEM KRAN AIR OTOMATIS MENGGUNAKAN SENSOR INFRARED AJDUSTABLE
Air merupakan sumber daya alam yang harus dijaga. Kebutuhan air semakin meningkat seiring dengan jumlah penduduk yang semakin besar. Sehingga ketika musim kemarau tiba cadangan air...
Rapid estimation of climate-air quality interactions in integrated assessment using a response surface model
Rapid estimation of climate-air quality interactions in integrated assessment using a response surface model
Air quality and climate change are substantial and linked sustainability challenges, and there is a need for improved tools to assess the implications of addressing them in combina...
Conceptual Development in Early Childhood
Conceptual Development in Early Childhood
The study of conceptual development in early childhood seeks to understand how infants and young children learn to filter, organize, and store disparate pieces of information, expe...

