Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Theoretical and Experimental Vibration Generation in a Coaxial Pulse-Tube Cryocooler

View through CrossRef
The microphonic noise induced by the vibration from cryocoolers has been found to cause energy resolution degradation in vibration-sensitive instruments. In this paper, theoretical and experimental research on the vibration generation mechanism of an aerospace-grade coaxial pulse-tube cryocooler (CPTC) is presented. Accordingly, suggestions for suppressing the vibration of the pulse-tube cryocooler are provided. A vibration model for the Oxford-type dual-opposed linear compressor is established, and the mechanism of vibration induced by the compressor is theoretically analyzed. A numerical simulation indicates that deviations in the compressor’s inductance coefficient, electromagnetic force coefficient, and flexure spring stiffness coefficient significantly affect the axial vibration of the compressor. The theoretical and experimental studies show that the high-order harmonic vibrations of the compressor are determined by both the resonance of the flexure springs and the high-order harmonics of the driving power supply. Through experiments and simulations, it is revealed that the dynamic gas pressure only induces vibration axially at the cold tip, while the radial vibration at the cold tip is determined by the heat head ‘s vibration and the structural response characteristics of the cold finger.
Title: Theoretical and Experimental Vibration Generation in a Coaxial Pulse-Tube Cryocooler
Description:
The microphonic noise induced by the vibration from cryocoolers has been found to cause energy resolution degradation in vibration-sensitive instruments.
In this paper, theoretical and experimental research on the vibration generation mechanism of an aerospace-grade coaxial pulse-tube cryocooler (CPTC) is presented.
Accordingly, suggestions for suppressing the vibration of the pulse-tube cryocooler are provided.
A vibration model for the Oxford-type dual-opposed linear compressor is established, and the mechanism of vibration induced by the compressor is theoretically analyzed.
A numerical simulation indicates that deviations in the compressor’s inductance coefficient, electromagnetic force coefficient, and flexure spring stiffness coefficient significantly affect the axial vibration of the compressor.
The theoretical and experimental studies show that the high-order harmonic vibrations of the compressor are determined by both the resonance of the flexure springs and the high-order harmonics of the driving power supply.
Through experiments and simulations, it is revealed that the dynamic gas pressure only induces vibration axially at the cold tip, while the radial vibration at the cold tip is determined by the heat head ‘s vibration and the structural response characteristics of the cold finger.

Related Results

Blunt Chest Trauma and Chylothorax: A Systematic Review
Blunt Chest Trauma and Chylothorax: A Systematic Review
Abstract Introduction: Although traumatic chylothorax is predominantly associated with penetrating injuries, instances following blunt trauma, as a rare and challenging condition, ...
Mixing of complex fluids with coaxial mixers composed of two central impellers and an anchor
Mixing of complex fluids with coaxial mixers composed of two central impellers and an anchor
The coaxial mixers composed of a high-speed central impeller and a low-speed anchor have been recommended by the previous researchers for the mixing of highly viscous and non-Newto...
Mixing of complex fluids with coaxial mixers composed of two central impellers and an anchor
Mixing of complex fluids with coaxial mixers composed of two central impellers and an anchor
The coaxial mixers composed of a high-speed central impeller and a low-speed anchor have been recommended by the previous researchers for the mixing of highly viscous and non-Newto...
Blades condition monitoring using shaft torsional vibration signals
Blades condition monitoring using shaft torsional vibration signals
PurposeThe purpose of this paper is to validate mathematically the feasibility of extracting the rotating blades vibration condition from the shaft torsional vibration measurement....
Study on Flow Induced Vibration Analysis and Evaluation for Heat Transfer Tube of Steam Generator in Two Phase Flow
Study on Flow Induced Vibration Analysis and Evaluation for Heat Transfer Tube of Steam Generator in Two Phase Flow
The flow induced vibration of heat transfer tube is one of the main factors leading to the failure of heat transfer tube in steam generator, the flow induced vibration of steam gen...
Environmental Surveillance Protocols for Highly Pathogenic Avian Influenza (HPAI) v2
Environmental Surveillance Protocols for Highly Pathogenic Avian Influenza (HPAI) v2
EnvironmentalSurveillance Protocols for Highly Pathogenic Avian Influenza (HPAI) This comprehensive protocol suite enables systematic environmental surveillance for avian influenza...
Features of vibration mixers design
Features of vibration mixers design
The article presents the results of the analysis of vibration mixers designs, presents their classification. The classification is based on the principle of action and the method o...
Analysis of S-Parameters for RF Coaxial Cables at Different Environmental Conditions
Analysis of S-Parameters for RF Coaxial Cables at Different Environmental Conditions
RF coaxial cables are essential components in radio frequency and microwave systems. RF coaxial cables are necessary for the test and measurement systems. In spacecraft (TTC & ...

Back to Top