Study on Flow Induced Vibration Analysis and Evaluation for Heat Transfer Tube of Steam Generator in Two Phase Flow

View through CrossRef
The flow induced vibration of heat transfer tube is one of the main factors leading to the failure of heat transfer tube in steam generator, the flow induced vibration of steam generator should be analyzed and evaluated in the design of steam generation. The flow induced vibration of heat transfer tube in two phase flow is the difficult and important content in the analysis. In this paper, the finite element model of heat transfer tube is established and the modal analysis is carried out. Then in order to evaluate the influence of two phase flow in the secondary side and support boundary constraint, the analytical results are compared with the natural frequency of the heat transfer tube measured in the two phase flow test. On the basis of accurate simulation of the dynamic characteristics of heat transfer tube in two phase flow, the paper calculate the turbulent excitation response and the fluid-elastic instability ratio aiming at the main mechanism causing the flow induced vibration of heat transfer tube in two phase flow. The modified PSD of turbulent excitation is proposed on the foundation of root mean square displacement amplitude of heat transfer tube measured in two phase flow test. The calculation result of the amplitude of heat transfer tube with different void fraction can envelope the test result by using the modified PSD as input, and the safety margin is reasonable. We also verify whether the analysis conclusion of fluid-elastic instability is in agreement with the test. The paper studies on flow induced vibration analysis and evaluation for heat transfer tube of steam generator in two phase flow, modifies the analysis program of flow induced vibration on the basis of the test results, the investigation can be used at the risk prediction and evaluation of flow induced vibration of heat transfer tube in two phase flow, solve the technical difficulties of flow induced vibration analysis in two phase flow, provide the technical support for the flow induced vibration analysis of steam generator in Hualong one.
Title: Study on Flow Induced Vibration Analysis and Evaluation for Heat Transfer Tube of Steam Generator in Two Phase Flow
Description:
The flow induced vibration of heat transfer tube is one of the main factors leading to the failure of heat transfer tube in steam generator, the flow induced vibration of steam generator should be analyzed and evaluated in the design of steam generation.
The flow induced vibration of heat transfer tube in two phase flow is the difficult and important content in the analysis.
In this paper, the finite element model of heat transfer tube is established and the modal analysis is carried out.
Then in order to evaluate the influence of two phase flow in the secondary side and support boundary constraint, the analytical results are compared with the natural frequency of the heat transfer tube measured in the two phase flow test.
On the basis of accurate simulation of the dynamic characteristics of heat transfer tube in two phase flow, the paper calculate the turbulent excitation response and the fluid-elastic instability ratio aiming at the main mechanism causing the flow induced vibration of heat transfer tube in two phase flow.
The modified PSD of turbulent excitation is proposed on the foundation of root mean square displacement amplitude of heat transfer tube measured in two phase flow test.
The calculation result of the amplitude of heat transfer tube with different void fraction can envelope the test result by using the modified PSD as input, and the safety margin is reasonable.
We also verify whether the analysis conclusion of fluid-elastic instability is in agreement with the test.
The paper studies on flow induced vibration analysis and evaluation for heat transfer tube of steam generator in two phase flow, modifies the analysis program of flow induced vibration on the basis of the test results, the investigation can be used at the risk prediction and evaluation of flow induced vibration of heat transfer tube in two phase flow, solve the technical difficulties of flow induced vibration analysis in two phase flow, provide the technical support for the flow induced vibration analysis of steam generator in Hualong one.

Related Results

Blunt Chest Trauma and Chylothorax: A Systematic Review
Blunt Chest Trauma and Chylothorax: A Systematic Review
Abstract Introduction: Although traumatic chylothorax is predominantly associated with penetrating injuries, instances following blunt trauma, as a rare and challenging condition, ...
The Hot Test of Primary Separation Equipment of Steam Generator for CAP1400 Nuclear Power Plant
The Hot Test of Primary Separation Equipment of Steam Generator for CAP1400 Nuclear Power Plant
A new type of Steam separator for CAP1400 Steam Generator is introduced. The result of characteristic experiment, the variables of which contain steam load, saturated water flow an...
DESIGN CHARACTERISTICS OF THE HORIZONTAL STEAM GENERATOR PGV-1000
DESIGN CHARACTERISTICS OF THE HORIZONTAL STEAM GENERATOR PGV-1000
The materials of the article consider the design characteristics of horizontal steam generators PGV-1000 for WWER NPPs. The NPP steam generator, in particular the PGV-1000 steam ge...
A Fast 3-D Interface Simulator for Steam Drives
A Fast 3-D Interface Simulator for Steam Drives
Abstract Here we describe a fast 3-D steam drive simulator. We use an interface model, where the single phase steam zone is separated from the two phase liquid zo...
Environmental Surveillance Protocols for Highly Pathogenic Avian Influenza (HPAI) v2
Environmental Surveillance Protocols for Highly Pathogenic Avian Influenza (HPAI) v2
EnvironmentalSurveillance Protocols for Highly Pathogenic Avian Influenza (HPAI) This comprehensive protocol suite enables systematic environmental surveillance for avian influenza...
TINBOP Cyclic Steam Injection Enhances Oil Recovery in Mature Steamfloods
TINBOP Cyclic Steam Injection Enhances Oil Recovery in Mature Steamfloods
Abstract In a previous paper (SPE/PS-CIM/CHOA 97850), we presented our findings on a novel cyclic steam injection method that we developed. The Top-Injection Bott...
Oil Vaporization During Steamflooding
Oil Vaporization During Steamflooding
Here is a procedure, intended for use with other techniques, for predicting the amount of oil vaporized, or distilled, in a steam zone predicting the amount of oil vaporized, or di...
Downhole Steam Generation for Green Heavy Oil Recovery
Downhole Steam Generation for Green Heavy Oil Recovery
Abstract The ultimate target of heavy oil recovery is to enhance oil mobility by transferring steam's thermal energy to the oil phase, incrementing its temperature, ...