Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Effect of Cavity Vacuum Pressure Diminution on Thermal Performance of Triple Vacuum Glazing

View through CrossRef
Long-term durability of the vacuum edge seal plays a significant part in retrofitting triple vacuum glazing (TVG) to existing buildings in achieving progress towards a zero-energy building (ZEB) target. Vacuum pressure decrement with respect to time between panes affects the thermal efficiency of TVG. This study reports a 3D finite element model, with validated mathematical methods and comparison, for the assessment of the influence of vacuum pressure diminution on the thermal transmittance (U value) of TVG. The centre-of-pane and total U values of TVG are calculated to be 0.28 Wm−2 K−1 and 0.94 Wm−2 K−1 at the cavity vacuum pressure of 0.001 Pa. The results suggest that a rise in cavity pressure from 0.001 Pa to 100 kPa increases the centre-of-pane and total U values from 0.28 Wm−2 K−1 and 0.94 Wm−2 K−1 to 2.4 Wm−2 K−1 and 2.58 Wm−2 K−1, respectively. The temperature descent on the surfaces of TVG between hot and cold sides increases by decreasing the cavity vacuum pressure from 50 kPa to 0.001 Pa. Nonevaporable getters will maintain the cavity vacuum pressure of 0.001 Pa for over 20 years of life span in the cavity of 10-mm wide edge-sealed triple vacuum glazing, and enable the long-term durability of TVG.
Title: Effect of Cavity Vacuum Pressure Diminution on Thermal Performance of Triple Vacuum Glazing
Description:
Long-term durability of the vacuum edge seal plays a significant part in retrofitting triple vacuum glazing (TVG) to existing buildings in achieving progress towards a zero-energy building (ZEB) target.
Vacuum pressure decrement with respect to time between panes affects the thermal efficiency of TVG.
This study reports a 3D finite element model, with validated mathematical methods and comparison, for the assessment of the influence of vacuum pressure diminution on the thermal transmittance (U value) of TVG.
The centre-of-pane and total U values of TVG are calculated to be 0.
28 Wm−2 K−1 and 0.
94 Wm−2 K−1 at the cavity vacuum pressure of 0.
001 Pa.
The results suggest that a rise in cavity pressure from 0.
001 Pa to 100 kPa increases the centre-of-pane and total U values from 0.
28 Wm−2 K−1 and 0.
94 Wm−2 K−1 to 2.
4 Wm−2 K−1 and 2.
58 Wm−2 K−1, respectively.
The temperature descent on the surfaces of TVG between hot and cold sides increases by decreasing the cavity vacuum pressure from 50 kPa to 0.
001 Pa.
Nonevaporable getters will maintain the cavity vacuum pressure of 0.
001 Pa for over 20 years of life span in the cavity of 10-mm wide edge-sealed triple vacuum glazing, and enable the long-term durability of TVG.

Related Results

Effect of Cavity Vacuum Pressure Diminution on Thermal Performance of Triple Vacuum Glazing
Effect of Cavity Vacuum Pressure Diminution on Thermal Performance of Triple Vacuum Glazing
Long-term durability of the vacuum edge-seal plays a significant part in retrofitting triple vacuum glazing (TVG) to existing buildings in achieving towards zero-energy buildings (...
Analysis of Heating and Cooling Loads of Electrochromic Glazing in High-Rise Residential Buildings in South Korea
Analysis of Heating and Cooling Loads of Electrochromic Glazing in High-Rise Residential Buildings in South Korea
This study compares the impact of the recently developed electrochromic glazing technology on load reduction by comparing it with the double-glazing and shading devices that are so...
Thermal Effects in High Compactness CEA Stack
Thermal Effects in High Compactness CEA Stack
Thermal management is a pivotal aspect of stack durability and system operability. Consequently, understanding the thermal mapping within a stack based on its operating conditions ...
Vacuum-Insulated Glazing Assessment by CFD Modeling and Laboratory Measurements
Vacuum-Insulated Glazing Assessment by CFD Modeling and Laboratory Measurements
This paper concerns measurements and CFD simulations of vacuum-insulated glazing (VIG), which consists of two glass panes separated by a narrow gap from which air has been removed....
Environmental Surveillance Protocols for Highly Pathogenic Avian Influenza (HPAI) v2
Environmental Surveillance Protocols for Highly Pathogenic Avian Influenza (HPAI) v2
EnvironmentalSurveillance Protocols for Highly Pathogenic Avian Influenza (HPAI) This comprehensive protocol suite enables systematic environmental surveillance for avian influenza...
Energy, Thermal, and Economic Benefits of Aerogel Glazing Systems for Educational Buildings in Hot Arid Climates
Energy, Thermal, and Economic Benefits of Aerogel Glazing Systems for Educational Buildings in Hot Arid Climates
The high cost of air conditioning during the summer makes it crucial to develop strategies to reduce energy use in buildings, especially in hot arid climates. Nanomaterial-based ex...
Thermal Performance Optimization of Double and Triple Glazing Systems for Slovenian Climate Conditions
Thermal Performance Optimization of Double and Triple Glazing Systems for Slovenian Climate Conditions
Glazing elements are an important part of the thermal envelope of a building. Therefore, good thermal performance of glazing elements can improve indoor comfort and reduce annual m...
Performance Analysis of Photo Voltaic Trombe Wall for Tropical Climate
Performance Analysis of Photo Voltaic Trombe Wall for Tropical Climate
The present study examines the performance of a single zone building integrated with PV Trombe wall (PV-TW) in term of thermal load reduction and electrical energy production by va...