Javascript must be enabled to continue!
Thermal Performance Optimization of Double and Triple Glazing Systems for Slovenian Climate Conditions
View through CrossRef
Glazing elements are an important part of the thermal envelope of a building. Therefore, good thermal performance of glazing elements can improve indoor comfort and reduce annual maintenance costs and CO2 (carbon dioxide) emissions by reducing heat loss. Reducing heat loss through glazing elements during the heating season can be achieved by combining low thermal transmittance with high solar heat gain. Using standardized calculation methods and measured climate data for three Slovenian locations representing typical continental, mountainous and Mediterranean climates, this study predicts the best combination of optical properties (emissivity, transmittance and reflectance) of glass panes in double and triple glazing systems that contribute to minimal heat loss. It was found that for the double glazing system, the minimum heating and cooling demand for buildings with low solar gains or high solar gains and applied shading is achieved by an inner pane with high transmittance without low-emissivity coating, and an outer pane with low-emissivity coating with minimum possible emissivity. In Maribor and Portorož climatic zones, the panes with low emissivity coating should be used as inner panes in buildings with high solar gains. For triple glazing, the minimum heating and cooling requirements are achieved with two or three panes with low emissivity. For buildings with low solar gains, an emissivity of the coating of 0.03 is preferable, but for buildings with high solar gains, lower emissivity values should be used.
Title: Thermal Performance Optimization of Double and Triple Glazing Systems for Slovenian Climate Conditions
Description:
Glazing elements are an important part of the thermal envelope of a building.
Therefore, good thermal performance of glazing elements can improve indoor comfort and reduce annual maintenance costs and CO2 (carbon dioxide) emissions by reducing heat loss.
Reducing heat loss through glazing elements during the heating season can be achieved by combining low thermal transmittance with high solar heat gain.
Using standardized calculation methods and measured climate data for three Slovenian locations representing typical continental, mountainous and Mediterranean climates, this study predicts the best combination of optical properties (emissivity, transmittance and reflectance) of glass panes in double and triple glazing systems that contribute to minimal heat loss.
It was found that for the double glazing system, the minimum heating and cooling demand for buildings with low solar gains or high solar gains and applied shading is achieved by an inner pane with high transmittance without low-emissivity coating, and an outer pane with low-emissivity coating with minimum possible emissivity.
In Maribor and Portorož climatic zones, the panes with low emissivity coating should be used as inner panes in buildings with high solar gains.
For triple glazing, the minimum heating and cooling requirements are achieved with two or three panes with low emissivity.
For buildings with low solar gains, an emissivity of the coating of 0.
03 is preferable, but for buildings with high solar gains, lower emissivity values should be used.
Related Results
CONTEMPORARY MILITARY CHALLENGES IN ENGLISH – A PROBLEM OR AN OPPORTUNITY
CONTEMPORARY MILITARY CHALLENGES IN ENGLISH – A PROBLEM OR AN OPPORTUNITY
Dear readers,You are looking at a new edition of the Contemporary Military Challenges, which includes contributions by the authors employed in Slovenian defence system; all except ...
“The Earth Is Dying, Bro”
“The Earth Is Dying, Bro”
Climate Change and Children
Australian children are uniquely situated in a vast landscape that varies drastically across locations. Spanning multiple climatic zones—from cool tempe...
Analysis of Heating and Cooling Loads of Electrochromic Glazing in High-Rise Residential Buildings in South Korea
Analysis of Heating and Cooling Loads of Electrochromic Glazing in High-Rise Residential Buildings in South Korea
This study compares the impact of the recently developed electrochromic glazing technology on load reduction by comparing it with the double-glazing and shading devices that are so...
Thermal Effects in High Compactness CEA Stack
Thermal Effects in High Compactness CEA Stack
Thermal management is a pivotal aspect of stack durability and system operability. Consequently, understanding the thermal mapping within a stack based on its operating conditions ...
Janko Kersnik
Janko Kersnik
Janko Kersnik (1852–1897) was involved in various fields: as a notary (briefly as an attorney), in economics and finance (property management, farming, forestry, hunting, etc.), in...
Ethics of climate change : a normative account
Ethics of climate change : a normative account
Consider, for instance, you and your family have lived around a place where you enjoyed the flora and fauna of the land as well as the natural environment. Fishing and farming were...
Climate and Culture
Climate and Culture
Climate is, presently, a heatedly discussed topic. Concerns about the environmental, economic, political and social consequences of climate change are of central interest in academ...
Architecture and adaptation
Architecture and adaptation
«The architectural work transcends the architect, goes beyond the moment in which its construction takes place, and therefore can be contemplated under the changing lights of histo...

