Digital modeling of critical conditions after metacarpophalangeal joint replacement
View through CrossRef
Introduction The current status of small joint arthroplasty, the metacarpophalangeal joint replacement, in particular, dictates the need for development and research of new implant designs and materials for their manufacture. The vector of development of anatomically adapted implants has become established, and full preclinical study is required to obtain the best functional results from the use of new medical devices. The objective was to analyze digital models of critical conditions of metacarpophalangeal joint replacement using mechanical and clinical data. Material and methods A two‑component all-ceramic, anatomically adapted endoprosthesis of the metacarpophalangeal joint was developed between 2017 and 2021. A digital model of the metacarpophalangeal joint endoprosthesis was constructed using 3D modeling technology. Critical conditions of the digital model imitating the main stereotypes of movements were explored with the finite element method; objective technical results obtained and interpreted in a clinical language. Results Loads over 20 kg should be avoided with movements up to 60° in the early postoperative period. The load must not exceed 10 kg for motion ranging between 60° and 90°. The endoprosthesis allowed for a functional range of motion of 30-60° after MCP joint replacement without significant risks of complications. Discussion The study has demonstrated the importance of objectifying clinical results to minimize the risk of complications in a clinical scenario. Conclusion The technology based on a digital model of the metacarpophalangeal joint constructed to calculate critical conditions using the Ansys software facilitated prediction of most common complications of MCP arthroplasty and preceded further multicentric clinical trials.
Russian Ilizarov Scientific Centre Restorative Traumatology and Orthopaedics
Title: Digital modeling of critical conditions after metacarpophalangeal joint replacement
Description:
Introduction The current status of small joint arthroplasty, the metacarpophalangeal joint replacement, in particular, dictates the need for development and research of new implant designs and materials for their manufacture.
The vector of development of anatomically adapted implants has become established, and full preclinical study is required to obtain the best functional results from the use of new medical devices.
The objective was to analyze digital models of critical conditions of metacarpophalangeal joint replacement using mechanical and clinical data.
Material and methods A two‑component all-ceramic, anatomically adapted endoprosthesis of the metacarpophalangeal joint was developed between 2017 and 2021.
A digital model of the metacarpophalangeal joint endoprosthesis was constructed using 3D modeling technology.
Critical conditions of the digital model imitating the main stereotypes of movements were explored with the finite element method; objective technical results obtained and interpreted in a clinical language.
Results Loads over 20 kg should be avoided with movements up to 60° in the early postoperative period.
The load must not exceed 10 kg for motion ranging between 60° and 90°.
The endoprosthesis allowed for a functional range of motion of 30-60° after MCP joint replacement without significant risks of complications.
Discussion The study has demonstrated the importance of objectifying clinical results to minimize the risk of complications in a clinical scenario.
Conclusion The technology based on a digital model of the metacarpophalangeal joint constructed to calculate critical conditions using the Ansys software facilitated prediction of most common complications of MCP arthroplasty and preceded further multicentric clinical trials.
Related Results
Arthroplasty of the metacarpophalangeal joint (literature review)
Arthroplasty of the metacarpophalangeal joint (literature review)
Introduction Diseases and injuries that affect the small joints of the hand, the metacarpophalangeal, in particular, lead to a limitated hand function and a reduced quality of life...
Access Denied
Access Denied
Introduction
As social-distancing mandates in response to COVID-19 restricted in-person data collection methods such as participant observation and interviews, researchers turned t...
Triple Joint Injuries of the Same Digit
Triple Joint Injuries of the Same Digit
This article presents a rare case of simultaneous triple joint injuries in the same digit. A 54-year-old, right-handed man sustained simultaneous triple joint injuries in a digit, ...
Differential Diagnosis of Neurogenic Thoracic Outlet Syndrome: A Review
Differential Diagnosis of Neurogenic Thoracic Outlet Syndrome: A Review
Abstract
Thoracic outlet syndrome (TOS) is a complex and often overlooked condition caused by the compression of neurovascular structures as they pass through the thoracic outlet. ...
The influence of micro influencers and digital marketing on product purchasing decisions at tiktok shop in bengkulu city
The influence of micro influencers and digital marketing on product purchasing decisions at tiktok shop in bengkulu city
THE INFLUENCE OF MICRO-INFLUENCERS AND DIGITAL MARKETING ON PURCHASE DECISIONS OF TIKTOK SHOP CUSTOMERS IN BENGKULU CITY
Andhes Tiani Putri, Meylaty F
12Faculty Of Economic
E...
Arthrocentesis approaches to the phalangeal joints of the one humped camel (Camelus dromedarius)
Arthrocentesis approaches to the phalangeal joints of the one humped camel (Camelus dromedarius)
AbstractIrrespective of the exceptional adaptation of dromedaries to harsh environmental conditions, they remain highly susceptible to joint lameness resulting from a range of dive...
The intersection of digital practices and environmental orientations: exploring digital-environmental habitus
The intersection of digital practices and environmental orientations: exploring digital-environmental habitus
Purpose
This study aims to examine how environmental dispositions and digital expertise influence sustainable digital behaviors. Drawing on Bourdieu’s theory of...
SCF Equations for T/Y and K Square-to-Round Tubular Joint
SCF Equations for T/Y and K Square-to-Round Tubular Joint
Summary
A parametric stress analysis of T/Y and K square-to-round tubular joints subjected to axial loads and in-plane and out-of-plane bending moments has been p...