Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Automated Power Window Opening on Carbon Monoxide Detection

View through CrossRef
This paper presents an embedded system for car cabin safety. A number of sudden deaths happened due to inhaling of carbon monoxide (CO) gas inside car cabin in the past years. The designed embedded system keeps on sensing the accumulated CO gas inside the car cabin. If the value of CO exceeds the predefined threshold value and the motion sensor installed in embedded system detects the presence of any occupant inside the car cabin, a warning text message gets displayed on LCD installed in car cabin and buzzer alarm is generated. The warning text message is sent by GSM kit to occupant cell phone. After receiving response from occupant, DTMF kit generates a preset sequence number and sends a signal to the microcontroller. On receiving this signal, control unit immediately sends signals to power window control circuit of the car to open the power windows to let fresh air come in the car and as the amount of CO reaches below predefined threshold value, power windows of car are rolled up again automatically.
Title: Automated Power Window Opening on Carbon Monoxide Detection
Description:
This paper presents an embedded system for car cabin safety.
A number of sudden deaths happened due to inhaling of carbon monoxide (CO) gas inside car cabin in the past years.
The designed embedded system keeps on sensing the accumulated CO gas inside the car cabin.
If the value of CO exceeds the predefined threshold value and the motion sensor installed in embedded system detects the presence of any occupant inside the car cabin, a warning text message gets displayed on LCD installed in car cabin and buzzer alarm is generated.
The warning text message is sent by GSM kit to occupant cell phone.
After receiving response from occupant, DTMF kit generates a preset sequence number and sends a signal to the microcontroller.
On receiving this signal, control unit immediately sends signals to power window control circuit of the car to open the power windows to let fresh air come in the car and as the amount of CO reaches below predefined threshold value, power windows of car are rolled up again automatically.

Related Results

Abnormal Brain Functional Network Dynamics in Acute CO Poisoning
Abnormal Brain Functional Network Dynamics in Acute CO Poisoning
Aims: Carbon monoxide poisoning is a common condition that can cause severe neurological sequelae. Previous studies have revealed that functional connectivity in carbon monoxide po...
Circulatory effects and kinetics following acute administration of carbon monoxide in a porcine model.
Circulatory effects and kinetics following acute administration of carbon monoxide in a porcine model.
Carbon monoxide is produced in the endothelial cells and has possible vasodilator activity through three different pathways. The aim of this study was to demonstrate circulatory ef...
Window Opening Behavior of Residential Buildings during the Transitional Season in China’s Xi’an
Window Opening Behavior of Residential Buildings during the Transitional Season in China’s Xi’an
Window opening behavior in residential buildings has important theoretical significance and practical value for improving energy conservation, indoor thermal comfort, and indoor ai...
Lychnos
Lychnos
Chronic carbon monoxide poisoning as a contested disease 1944–1961. By Helena Ekerholm. During World War II, wood gas became the primary fuel for Swedish motorists. Although reliab...
Proposing A New Variable Window for Better Side Lobe Reduction
Proposing A New Variable Window for Better Side Lobe Reduction
Digital signal processing is most widely used to process the signal. In digital signal processing filters are used to remove some unwanted constituents from aspired signal. Windowi...
Carbon monoxide in intensive care medicine—time to start the therapeutic application?!
Carbon monoxide in intensive care medicine—time to start the therapeutic application?!
AbstractCarbon monoxide (CO) is not only known as a toxic gas due to its characteristics as an odorless molecule and its rapid binding to haem-containing molecules, thus inhibiting...
Ecology of Yuqing County Carbon Sink Calculation and Ecosystem Protection Measures
Ecology of Yuqing County Carbon Sink Calculation and Ecosystem Protection Measures
Based on the remote sensing statistical data of land use of terrestrial ecosystems in Yuqing County, this paper calculates the amount of carbon sinks in the county according to the...
Seismic Response Optimization of RC Slabs: Influence of Opening Location, Size, and Geometry on Structural Performance
Seismic Response Optimization of RC Slabs: Influence of Opening Location, Size, and Geometry on Structural Performance
In this research, the influence of the location, area and shape of the openings on the seismic behavior and performance of the concrete slab roof was evaluated and studied using th...

Back to Top