Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Circulatory effects and kinetics following acute administration of carbon monoxide in a porcine model.

View through Europeana Collections
Carbon monoxide is produced in the endothelial cells and has possible vasodilator activity through three different pathways. The aim of this study was to demonstrate circulatory effects after administration of saturated carbon monoxide blood and to describe the pharmacokinetics of carbon monoxide. Six pigs were anesthetized and 150 ml blood was removed. This blood was bubbled with carbon monoxide until the carboxyhemoglobin (COHb) levels were 90-99%. A specific amount of this blood was then injected back to the animal. At predetermined times; arterial and mixed venous blood was drawn and analyzed for carbon monoxide. Systemic and pulmonary vascular resistance index (SVRi and PVRi) were measured and exhaled air was sampled and measured for carbon monoxide. Blood samples were gathered over 300 minutes along with measurements of invasive pressures, heart rate, cardiac output, oxygen saturation (SpO2), Hb, temperature and blood gases. We conclude that this type of exposure to carbon monoxide appears to have little or no effect on general vasomotor tone and, after correcting for basal levels of carbon monoxide, elimination occurs through the lungs as predicted by a single compartment model. The half-life of carbon monoxide was determined to be 60.5 minutes (SEM 4.7).
image-zoom
Title: Circulatory effects and kinetics following acute administration of carbon monoxide in a porcine model.
Description:
Carbon monoxide is produced in the endothelial cells and has possible vasodilator activity through three different pathways.
The aim of this study was to demonstrate circulatory effects after administration of saturated carbon monoxide blood and to describe the pharmacokinetics of carbon monoxide.
Six pigs were anesthetized and 150 ml blood was removed.
This blood was bubbled with carbon monoxide until the carboxyhemoglobin (COHb) levels were 90-99%.
A specific amount of this blood was then injected back to the animal.
At predetermined times; arterial and mixed venous blood was drawn and analyzed for carbon monoxide.
Systemic and pulmonary vascular resistance index (SVRi and PVRi) were measured and exhaled air was sampled and measured for carbon monoxide.
Blood samples were gathered over 300 minutes along with measurements of invasive pressures, heart rate, cardiac output, oxygen saturation (SpO2), Hb, temperature and blood gases.
We conclude that this type of exposure to carbon monoxide appears to have little or no effect on general vasomotor tone and, after correcting for basal levels of carbon monoxide, elimination occurs through the lungs as predicted by a single compartment model.
The half-life of carbon monoxide was determined to be 60.
5 minutes (SEM 4.
7).

Related Results

Abnormal Brain Functional Network Dynamics in Acute CO Poisoning
Abnormal Brain Functional Network Dynamics in Acute CO Poisoning
Aims: Carbon monoxide poisoning is a common condition that can cause severe neurological sequelae. Previous studies have revealed that functional connectivity in carbon monoxide po...
Contribution of immune response to the hepatic fibrosis induced by porcine serum
Contribution of immune response to the hepatic fibrosis induced by porcine serum
To investigate whether hepatic fibrosis induced by porcine serum in rats is caused by an immune reaction to porcine serum, rats that were immunologically tolerant exclusively to po...
Characteristics of Headache Associated With Acute Carbon Monoxide Poisoning
Characteristics of Headache Associated With Acute Carbon Monoxide Poisoning
Objective.—To evaluate systematically the characteristics of headache due to acute exposure to carbon monoxide. Background.—Headache is the most commonly reported...
Porcine zona pellucida glycoprotein ZP4 is responsible for the sperm-binding activity of the ZP3/ZP4 complex
Porcine zona pellucida glycoprotein ZP4 is responsible for the sperm-binding activity of the ZP3/ZP4 complex
SummaryThe zona pellucida (ZP) is a transparent envelope that surrounds the mammalian oocyte and mediates species-selective sperm–egg interactions. Porcine and bovine ZPs consist o...
Evaluation of Blood Levels of Carbon Monoxide in Smokers in Nnewi Metropolis
Evaluation of Blood Levels of Carbon Monoxide in Smokers in Nnewi Metropolis
Cigarette smoking is a major source of exposure to carbon monoxide (CO). CO is a colourless, odourless gas that displaces oxygen in the blood, which can lead to a variety of health...

Back to Top