JUSTIFIKASI PROTOKOL COMPUTED TOMOGRAPHY CARDIAC PROSPECTIVE DAN RETROSPECTIVE DITINJAU DARI ANALISIS KUALITAS CITRA DAN ESTIMASI DOSIS RADIASI
View through CrossRef
Cardiac CT is an imaging technique that detects the condition of the coronary arteries. EKG-triggered techniques are used to improve the resolution of coronary artery images and minimize artifacts caused by cardiac motion. Retrospective cardiac computed tomography remains the first choice for maximum image quality, especially in relative contraindications such as arrhythmias and high heart rates during the cardiac cycle. The prospective technique can significantly reduce the radiation dose compared with the retrospective technique. This study aimed to see the effectiveness of this prospective technique in terms of radiation dose and image quality. The effective dose analysis method is with indoseCT software and calculated with a formula from CTDIvol and DLP. Image quality was assessed by calculating the SNR by comparing prospective and retrospective techniques. The study results regarding image quality show that the retrospective method has an SNR value of 44, and the SNR value of the prospective method is 35. Dose estimation by indoseCT software obtained results. Retrospective techniques yield the following results: The effective dose is 24.09 mSv, and the prospective technique provides an effective dose of 12.54 mSv. Using the prospective technique shows that the dose can be reduced by 47.94% compared with the retrospective technique. The estimated dose was manually calculated based on CTDIvol and DLP, resulting in an effective dose of 33.5 mSv with the retrospective technique and an effective dose of 11.95 mSv with the prospective technique. Using the prospective technique shows that the dose can be reduced by 64.32% compared with the retrospective technique. The rationale for choosing a potential cardiac CT regimen must be careful and precise, as it may not apply to all patients. Use recommendations apply only to patients with low, stable heart rates and less than five bpm variability. Keywords: CT Cardiac, effective dose, Retrospective ECG-Gating, Prospective ECG-Gating.
Title: JUSTIFIKASI PROTOKOL COMPUTED TOMOGRAPHY CARDIAC PROSPECTIVE DAN RETROSPECTIVE DITINJAU DARI ANALISIS KUALITAS CITRA DAN ESTIMASI DOSIS RADIASI
Description:
Cardiac CT is an imaging technique that detects the condition of the coronary arteries.
EKG-triggered techniques are used to improve the resolution of coronary artery images and minimize artifacts caused by cardiac motion.
Retrospective cardiac computed tomography remains the first choice for maximum image quality, especially in relative contraindications such as arrhythmias and high heart rates during the cardiac cycle.
The prospective technique can significantly reduce the radiation dose compared with the retrospective technique.
This study aimed to see the effectiveness of this prospective technique in terms of radiation dose and image quality.
The effective dose analysis method is with indoseCT software and calculated with a formula from CTDIvol and DLP.
Image quality was assessed by calculating the SNR by comparing prospective and retrospective techniques.
The study results regarding image quality show that the retrospective method has an SNR value of 44, and the SNR value of the prospective method is 35.
Dose estimation by indoseCT software obtained results.
Retrospective techniques yield the following results: The effective dose is 24.
09 mSv, and the prospective technique provides an effective dose of 12.
54 mSv.
Using the prospective technique shows that the dose can be reduced by 47.
94% compared with the retrospective technique.
The estimated dose was manually calculated based on CTDIvol and DLP, resulting in an effective dose of 33.
5 mSv with the retrospective technique and an effective dose of 11.
95 mSv with the prospective technique.
Using the prospective technique shows that the dose can be reduced by 64.
32% compared with the retrospective technique.
The rationale for choosing a potential cardiac CT regimen must be careful and precise, as it may not apply to all patients.
Use recommendations apply only to patients with low, stable heart rates and less than five bpm variability.
Keywords: CT Cardiac, effective dose, Retrospective ECG-Gating, Prospective ECG-Gating.
Related Results
Verifikasi Dosis Radiasi Teknik Penyinaran 3D-CRT pada Pasien Kanker Payudara Menggunakan Film EBT3 di Rumah Sakit UNAND
Verifikasi Dosis Radiasi Teknik Penyinaran 3D-CRT pada Pasien Kanker Payudara Menggunakan Film EBT3 di Rumah Sakit UNAND
Verifikasi dosis radiasi teknik penyinaran Three-Dimensional Conformal Radiation Therapy  (3D-CRT) pada pasien kanker payudara telah dilakukan menggunakan film EBT3. Verifikasi do...
Pengantar Sistem Proteksi Radiasi
Pengantar Sistem Proteksi Radiasi
Selain membawa manfaat yang sangat besar, penggunaan tenaga nuklir diketahui memiliki efek yang berbahaya bagi kesehatan manusia. Efek radiasi yang dihasilkan dari tenaga nuklir da...
Pengukuran Dosis Radiasi dan Estimasi Efek Biologis yang Diterima Pasien Radiografi Gigi Anak Menggunakan TLD-100 pada Titik Pengukuran Mata dan Timus
Pengukuran Dosis Radiasi dan Estimasi Efek Biologis yang Diterima Pasien Radiografi Gigi Anak Menggunakan TLD-100 pada Titik Pengukuran Mata dan Timus
Penelitian tentang pengukuran dosis radiasi yang diterima pasien radiografi gigi anak pada titik pengukuran mata dan timus telah dilakukan pada salah satu rumah sakit di kota Pada...
ENKRIPSI DAN DEKRIPSI CITRA MENGGUNAKAN METODE FRAKTAL
ENKRIPSI DAN DEKRIPSI CITRA MENGGUNAKAN METODE FRAKTAL
Enkripsi citra dengan metode fraktal adalah proses penyandian yang mengubah citra asli (plain image) menjadi citra yang tidak bisa dimengerti (cipher image) dengan menggunakan citr...
PENGGUNAAN CITRA HIMPUNAN JULIA SEBAGAI CITRA SAMPUL UNTUK MENYEMBUNYIKAN CITRA RAHASIA
PENGGUNAAN CITRA HIMPUNAN JULIA SEBAGAI CITRA SAMPUL UNTUK MENYEMBUNYIKAN CITRA RAHASIA
Steganografi dengan metode fraktal (fractal steganography) adalah teknik menyembunyikan informasi atau pesan, yang dapat berupa citra rahasia, dalam suatu citra sampul (cover image...
ANALISIS PENERAPAN KESELAMATAN RADIASI SINAR-X PADA PEKERJA RADIASI DI INSTALASI RADIOLOGI RUMAH SAKIT PEKANBARU MEDICAL CENTER (PMC) TAHUN 2020
ANALISIS PENERAPAN KESELAMATAN RADIASI SINAR-X PADA PEKERJA RADIASI DI INSTALASI RADIOLOGI RUMAH SAKIT PEKANBARU MEDICAL CENTER (PMC) TAHUN 2020
Keselamatan radiasi adalah tindakan yang dilakukan untuk melindungi pasien, pekerja, masyarakat, dan lingkungan hidup dari bahaya radiasi. Mengingat potensi bahaya radiasi yang bes...
Evaluasi Variasi Faktor Eksposi Terhadap Dosis Paparan Radiasi Pada Pesawat Sinar-X Model E7242 di RSUD Madani Palu
Evaluasi Variasi Faktor Eksposi Terhadap Dosis Paparan Radiasi Pada Pesawat Sinar-X Model E7242 di RSUD Madani Palu
Telah dilakukan penelitian Evaluasi Variasi Faktor Eksposi Terhadap Dosis Paparan Radiasi Pada Pesawat Sinar-X Model E7242 di RSUD Madani Palu. Penelitian ini dilakukan untuk menge...
Perbaikan Kualitas Citra Menggunakan Metode Fuzzy Type-2
Perbaikan Kualitas Citra Menggunakan Metode Fuzzy Type-2
Image enhancement is applied to an image that has low contrast. Histogram Equalization (HE) is a general method used to improve the quality of an image. However, its drawback is f...