Calibration of X-ray spectrometers for opacity experiments at the Orion laser facility (invited)

View through CrossRef
Accurately calibrated and characterised x-ray diagnostics are a key requirement in the fielding of experiments on the Orion laser where absolute measurements of x-ray emission are used to underpin the validity of models of emissivity and opacity. Diffraction crystals are used in spectrometers on Orion to record the dispersed spectral features emitted by the laser produced plasma to obtain a measurement of the plasma conditions. The ability to undertake diffraction crystal calibrations supports the successful outcome of these Orion experiments. This paper details the design and commissioning of a system to undertake these calibrations in the energy range 2.0 keV to approximately 8.5 keV. Improvements to the design are detailed which will extend the commissioned range of energies to below 1 keV.
Title: Calibration of X-ray spectrometers for opacity experiments at the Orion laser facility (invited)
Description:
Accurately calibrated and characterised x-ray diagnostics are a key requirement in the fielding of experiments on the Orion laser where absolute measurements of x-ray emission are used to underpin the validity of models of emissivity and opacity.
Diffraction crystals are used in spectrometers on Orion to record the dispersed spectral features emitted by the laser produced plasma to obtain a measurement of the plasma conditions.
The ability to undertake diffraction crystal calibrations supports the successful outcome of these Orion experiments.
This paper details the design and commissioning of a system to undertake these calibrations in the energy range 2.
0 keV to approximately 8.
5 keV.
Improvements to the design are detailed which will extend the commissioned range of energies to below 1 keV.

Related Results

Automatic Hand-Eye Calibration Method of Welding Robot Based on Linear Structured Light
Automatic Hand-Eye Calibration Method of Welding Robot Based on Linear Structured Light
Aiming at solving the problems such as long calibration time, low precision, and complex operation in hand-eye calibration of welding robot, an automatic hand-eye calibration algor...
Double resonant sum-frequency generation in an external-cavity under high-efficiency frequency conversion
Double resonant sum-frequency generation in an external-cavity under high-efficiency frequency conversion
In recent years, more than 90% of the signal laser power can be up-converted based on the high-efficiency double resonant external cavity sum-frequency generation (SFG), especially...
Excimer Laser Micromachining of MEMS Materials
Excimer Laser Micromachining of MEMS Materials
Conventional photolithography-based microfabrication techniques are limited to two-dimensional fabrication and only particular materials can be used. Excimer laser micromachining e...
Development of a high intensity Mid-Ir OPCPA pumped by a HO:YLF amplifier
Development of a high intensity Mid-Ir OPCPA pumped by a HO:YLF amplifier
The continuous development of laser sources delivering ultra-short light pulses underpins much of the current progress in experimental science, particularly in the domain of physic...
Laser show safety for smaller shows: The ILDA category a laser show standard
Laser show safety for smaller shows: The ILDA category a laser show standard
The International Laser Display Association has developed a “Category A Standard” for laser shows that ILDA considers to be generally recognized as safe under the conditions of the...
Orion
Orion
Entre élégance stylistique et science des mythes, quelle est la position d’Euphorion dans le jeu littéraire hellénistique ? L’étude du personnage d’Orion peut apporter quelques lum...
A new double crystal calibration system for absolute x-ray emission measurements down to ∼1 keV energies
A new double crystal calibration system for absolute x-ray emission measurements down to ∼1 keV energies
Over the past few years, work has been conducted at AWE to accurately characterize x-ray diffraction crystals to allow for absolute measurements of x-ray emission for our Orion opa...
Evaluation of an Opacity Lensometer for Determining Corneal Clarity Following Excimer Laser Photoablation
Evaluation of an Opacity Lensometer for Determining Corneal Clarity Following Excimer Laser Photoablation
ABSTRACT: The appearance of haze in the central cornea following photoablation with a 193 nm excimer laser is an important factor in the postoperative course of this procedure. Dat...

Back to Top