Javascript must be enabled to continue!
Effect of PTH and corticotomy on implant movement under mechanical force
View through CrossRef
Abstract
BackgroundOsseointegrated implants are considered as clinically non-movable. Parathyroid hormone (PTH) is known to play a significant role in the regulation of bone remodeling and in intermittent, low doses, result in osteoanabolic effects. This study aimed to investigate the effects of PTH and corticotomy, both under traction force, on osseointegrated implants.MethodsFour implants—two in each hemimandible—were placed in each of the three study mongrels. Each mongrels were designated as control, normal dose PTH (PTH-1), and high dose PTH (PTH-2) groups, with each groups further subdivided into non-surgery implant and surgery implant. After osseointegration, mechanical force with NiTi closed coil springs (500g) was applied around each implants. Corticotomy was performed around one of four implants in each mongrels. Parathyroid hormone was administered locally on a weekly basis for 20 weeks. Clinical movement of the implants were evaluated with the superimposed 3D- scanned data, bone- microarchitectural and histologic examinations.ResultsSuperimposition analysis showed continuous movement of the non-surgery implant of PTH-1 group. Movement was further justified with lowest bone implant contact (adjusted BIC; 44.77%) in histomorphometric analysis. Upregulation of bone remodeling around the implant was observed in the normal dose PTH group. In the surgery implants, the remarkably higher adjusted BIC compared to the non-surgery implants indicated increased bone formation around the implant surface. ConclusionThe results indicate that the catabolic and anabolic balance of osseointegrated implants in terms of bone remodeling can be shifted via various interventions including pharmacological, surgical and mechanical force.Clinical RelevanceUpregulated bone remodeling by PTH and corticotomy under continuous mechanical force showed the possible implications for the movement of osseointegrated dental implant.
Title: Effect of PTH and corticotomy on implant movement under mechanical force
Description:
Abstract
BackgroundOsseointegrated implants are considered as clinically non-movable.
Parathyroid hormone (PTH) is known to play a significant role in the regulation of bone remodeling and in intermittent, low doses, result in osteoanabolic effects.
This study aimed to investigate the effects of PTH and corticotomy, both under traction force, on osseointegrated implants.
MethodsFour implants—two in each hemimandible—were placed in each of the three study mongrels.
Each mongrels were designated as control, normal dose PTH (PTH-1), and high dose PTH (PTH-2) groups, with each groups further subdivided into non-surgery implant and surgery implant.
After osseointegration, mechanical force with NiTi closed coil springs (500g) was applied around each implants.
Corticotomy was performed around one of four implants in each mongrels.
Parathyroid hormone was administered locally on a weekly basis for 20 weeks.
Clinical movement of the implants were evaluated with the superimposed 3D- scanned data, bone- microarchitectural and histologic examinations.
ResultsSuperimposition analysis showed continuous movement of the non-surgery implant of PTH-1 group.
Movement was further justified with lowest bone implant contact (adjusted BIC; 44.
77%) in histomorphometric analysis.
Upregulation of bone remodeling around the implant was observed in the normal dose PTH group.
In the surgery implants, the remarkably higher adjusted BIC compared to the non-surgery implants indicated increased bone formation around the implant surface.
ConclusionThe results indicate that the catabolic and anabolic balance of osseointegrated implants in terms of bone remodeling can be shifted via various interventions including pharmacological, surgical and mechanical force.
Clinical RelevanceUpregulated bone remodeling by PTH and corticotomy under continuous mechanical force showed the possible implications for the movement of osseointegrated dental implant.
Related Results
After the paint has dried: a review of testing techniques for studying the mechanical properties of artists’ paint
After the paint has dried: a review of testing techniques for studying the mechanical properties of artists’ paint
AbstractWhile the chemistry of artists’ paints has previously been studied and reviewed, these studies only capture a portion of the properties affecting the response of paint mate...
Affective Movement in Robotic Art: Alternatives to the ‘Interiority Paradigm’ in Social Robotics
Affective Movement in Robotic Art: Alternatives to the ‘Interiority Paradigm’ in Social Robotics
This paper criticallyevaluates how emotional and intentional movement is conceptualised and deployedin social robotics and provides an alternative by analysing contemporary robotic...
A Device for Measuring the Removal Force of Peaches1
A Device for Measuring the Removal Force of Peaches1
Abstract
A device was designed to permit accurate and rapid measurement of the abscission or removal force of peaches when used with a mechanical force gauge. To handle fruit of di...
Toward Objective Measurement and Evaluation of Jazz Piano Performance Via MIDI-Based Groove Quantize Templates
Toward Objective Measurement and Evaluation of Jazz Piano Performance Via MIDI-Based Groove Quantize Templates
The purpose of this study was to (a) objectively measure and analyze performance deviations from mechanical regularity for three jazz pianists via MIDI-based "groove quantize" proc...
Is your memory better than mine? Investigating the mechanisms and determinants of the memory conformity effect using a modified MORI technique
Is your memory better than mine? Investigating the mechanisms and determinants of the memory conformity effect using a modified MORI technique
SummaryThe paper presents the memory conformity effect phenomenon, which assumes that information about the same event that a witness acquires from another witness (misinformation)...
Analysis of Notch Effect in Fracture Micromechanisms
Analysis of Notch Effect in Fracture Micromechanisms
This paper presents an analysis of the notch effect in fracture micromechanisms. To this end, experimental results obtained in notched specimens are presented, together with the co...
Abolitionist futures and the US sanctuary movement
Abolitionist futures and the US sanctuary movement
This article focuses on the histories, current challenges, and future directions of the sanctuary movement in the United States, which is becoming a central front of resistance to ...
Regulation of the ubiquitin proteasome system in mechanically injured human skeletal muscle
Regulation of the ubiquitin proteasome system in mechanically injured human skeletal muscle
Metabolic consequences of direct muscle trauma are insufficiently defined. Their effects on the ubiquitin-proteasome pathway (UPP) of protein degradation in human skeletal muscles ...