Javascript must be enabled to continue!
The effect of fresh frozen plasma in critically ill patients
View through CrossRef
BackgroundCritically ill patients often receive fresh frozen plasma (FFP) if they have abnormal conventional coagulation tests. The aim of this study was to investigate the effect of FFP transfusion judged by a wide range of coagulation tests.MethodsWe included 30 critically ill patients receiving FFP and 30 critically ill patients who did not receive FFP. For patients receiving FFP, blood samples were obtained before and 1 h after FFP transfusion. Conventional coagulation tests, thromboelastometry (ROTEM®, EXTEM, INTEM and FIBTEM) and thrombin generation were performed. Systematic recording of vital signs was performed for all patients.ResultsThe median values of the conventional coagulation tests were abnormal before and after FFP (PT: (normal > 0.6) median 0.3 before vs. 0.3 after; INR: (normal < 1.2) median 2 before vs. 1.7 after; APTT: (normal < 38 s) median 45 s before vs. 42 s after). Eight of nine ROTEM® parameters were within the reference interval judged by median values before FFP transfusion, and all median parameters were within the reference interval after FFP transfusion. Median in three of four thrombin generation parameters was within the reference interval both before and after FFP transfusion.ConclusionPatients presented abnormal conventional coagulation tests both before and after FFP transfusion. In contrast, ROTEM® and thrombin generation parameters were mainly within the reference interval both before and after FFP transfusion. FFP transfusions caused only negligible, although statically significant, improvements on coagulation measurements judged by conventional coagulation tests, ROTEM® and thrombin generation.
Title: The effect of fresh frozen plasma in critically ill patients
Description:
BackgroundCritically ill patients often receive fresh frozen plasma (FFP) if they have abnormal conventional coagulation tests.
The aim of this study was to investigate the effect of FFP transfusion judged by a wide range of coagulation tests.
MethodsWe included 30 critically ill patients receiving FFP and 30 critically ill patients who did not receive FFP.
For patients receiving FFP, blood samples were obtained before and 1 h after FFP transfusion.
Conventional coagulation tests, thromboelastometry (ROTEM®, EXTEM, INTEM and FIBTEM) and thrombin generation were performed.
Systematic recording of vital signs was performed for all patients.
ResultsThe median values of the conventional coagulation tests were abnormal before and after FFP (PT: (normal > 0.
6) median 0.
3 before vs.
0.
3 after; INR: (normal < 1.
2) median 2 before vs.
1.
7 after; APTT: (normal < 38 s) median 45 s before vs.
42 s after).
Eight of nine ROTEM® parameters were within the reference interval judged by median values before FFP transfusion, and all median parameters were within the reference interval after FFP transfusion.
Median in three of four thrombin generation parameters was within the reference interval both before and after FFP transfusion.
ConclusionPatients presented abnormal conventional coagulation tests both before and after FFP transfusion.
In contrast, ROTEM® and thrombin generation parameters were mainly within the reference interval both before and after FFP transfusion.
FFP transfusions caused only negligible, although statically significant, improvements on coagulation measurements judged by conventional coagulation tests, ROTEM® and thrombin generation.
Related Results
Salmonella occurrence and myoglobin (mb) in frozen smoked tuna
Salmonella occurrence and myoglobin (mb) in frozen smoked tuna
Title (Bahasa Indonesia): Keberadaan salmonella dan tingkat kesegaran frozen smoked tuna
This study aimed to quantify Salmonella, Total and Total Plate Count (TPC) in ...
KINEMATICS OF SPERMATOZOA IN FRESH AND FROZEN SEMEN OF PESISIR CATTLE
KINEMATICS OF SPERMATOZOA IN FRESH AND FROZEN SEMEN OF PESISIR CATTLE
This study aimed to evaluate the quality and kinematics of spermatozoa in fresh and frozen semen of coastal cattle. Semen of coastal cattle was collected using an artificial vagina...
Studi Literatur: Aplikasi dan Fungsi Porang (Amorphophallus Oncophyllus) dalam Frozen Yoghurt
Studi Literatur: Aplikasi dan Fungsi Porang (Amorphophallus Oncophyllus) dalam Frozen Yoghurt
Abstract — Frozen yoghurt is a frozen desserts made with yoghurt and quite similar to ice cream but low in calorie, which cointains milk, sweetener, stabilizers, emulsifier, and la...
Magnetohydrodynamics enhanced radio blackout mitigation system for spacecraft during planetary entries
Magnetohydrodynamics enhanced radio blackout mitigation system for spacecraft during planetary entries
(English) Spacecraft entering planetary atmospheres are enveloped by a plasma layer with high levels of ionization, caused by the extreme temperatures in the shock layer. The charg...
P-072 Fresh testicular sperm seems to yield more fertilization abnormalities and early pregnancy loss than frozen testicular sperm
P-072 Fresh testicular sperm seems to yield more fertilization abnormalities and early pregnancy loss than frozen testicular sperm
Abstract
Study question
How do ICSI outcomes using fresh testicular sperm, compare to those using frozen samples cryopreserved f...
71 BOVINE SPERM DEATH KINETICS: CHANGES IN MOTILITY, ACROSOMES, AND PLASMA MEMBRANE
71 BOVINE SPERM DEATH KINETICS: CHANGES IN MOTILITY, ACROSOMES, AND PLASMA MEMBRANE
Extent and timing of alterations in structures and functions of sperm after its placement in the female reproductive tract are important for successful fertilization. To our knowle...
A microfluidic analysis of thrombus formation in reconstituted whole blood samples comparing spray‐dried plasma versus fresh frozen plasma
A microfluidic analysis of thrombus formation in reconstituted whole blood samples comparing spray‐dried plasma versus fresh frozen plasma
BackgroundPrompt resuscitation with plasma and other blood products reduces trauma‐related morbidity and mortality. Standard storage and preparation techniques for frozen plasma li...
Assessment of Microbial Load in Fresh and Frozen Broiler Chicken Samples from Lahore
Assessment of Microbial Load in Fresh and Frozen Broiler Chicken Samples from Lahore
Contaminated chicken meat and its products pose significant hazards to human health. This study was designed to evaluate the quality and microbial safety of fresh and frozen broile...

