Analisis Daya Dukung Pondasi Tiang Bored Pile Pada Proyek Morrissey
View through CrossRef
The foundation is the lowest structural component of a building. All the load of the building is supported by the foundation. transferring the load to the soil below. Shallow foundations and deep foundations are two categories of foundations. The Morrissey hotel project uses bored pile foundation, as bored pile foundation is used for buildings in densely populated areas. Bored pile foundation is done by using a drilling machine to drill a hole of a certain depth, then filled with cast concrete and iron bones. This technique is considered to produce a foundation with good durability, especially over a long period of time. Various techniques in bored pile calculation, including conus penetration test (CPT), standard penetration test (SPT), and assessment based on soil shear strength characteristics such as cohesion (c), inner shear angle (?), and soil content weight (?), can be used to determine the bearing capacity of bored piles. The tip bearing capacity (Qb) and the blanket friction bearing capacity (????????), which are determined using the formula, are the two main parts of the bored pile axial bearing capacity.
Title: Analisis Daya Dukung Pondasi Tiang Bored Pile Pada Proyek Morrissey
Description:
The foundation is the lowest structural component of a building.
All the load of the building is supported by the foundation.
transferring the load to the soil below.
Shallow foundations and deep foundations are two categories of foundations.
The Morrissey hotel project uses bored pile foundation, as bored pile foundation is used for buildings in densely populated areas.
Bored pile foundation is done by using a drilling machine to drill a hole of a certain depth, then filled with cast concrete and iron bones.
This technique is considered to produce a foundation with good durability, especially over a long period of time.
Various techniques in bored pile calculation, including conus penetration test (CPT), standard penetration test (SPT), and assessment based on soil shear strength characteristics such as cohesion (c), inner shear angle (?), and soil content weight (?), can be used to determine the bearing capacity of bored piles.
The tip bearing capacity (Qb) and the blanket friction bearing capacity (????????), which are determined using the formula, are the two main parts of the bored pile axial bearing capacity.
Related Results
STUDI PERBANDINGAN DAYA DUKUNG PONDASI TIANG TUNGGAL DAN TIANG KELOMPOK DENGAN BEBERAPA VARIASI DIMENSI PENAMPANG TIANG DITINJAU TERHADAP NILAI EKONOMIS (Studi Kasus: Pembangunan Gedung Rektorat UNISKA MAB Banjarmasin)
STUDI PERBANDINGAN DAYA DUKUNG PONDASI TIANG TUNGGAL DAN TIANG KELOMPOK DENGAN BEBERAPA VARIASI DIMENSI PENAMPANG TIANG DITINJAU TERHADAP NILAI EKONOMIS (Studi Kasus: Pembangunan Gedung Rektorat UNISKA MAB Banjarmasin)
Gedung Rektorat Universitas Islam Kalimantan (UNISKA) Muhammad Arsyad Al Banjari (MAB) adalah proyek strategis yang bertujuan untuk meningkatkan kualitas infrastruktur pendidikan d...
HUBUNGAN EFISIENSI KAPASITAS DUKUNG TERHADAP JARAK ANTAR TIANG PADA KELOMPOK TIANG
HUBUNGAN EFISIENSI KAPASITAS DUKUNG TERHADAP JARAK ANTAR TIANG PADA KELOMPOK TIANG
This study aims to determine the most effective bored pile spacing to support the load of a structure. This study used a group pile configuration with dimensions 10x10, 30 m long, ...
Analisis Daya Dukung Pondasi Spun Pile Dievaluasi Dengan Kalendering Dan PDA
Analisis Daya Dukung Pondasi Spun Pile Dievaluasi Dengan Kalendering Dan PDA
Dalam suatu proyek konstruksi jembatan, terdapat dua jenis struktur, yaitu struktur atas dan struktur bawah. Pondasi merupakan bagian dari struktur bawah yang berfungsi sebagai pen...
ANALISIS PENGARUH DIAMETER TIANG TERHADAP DAYA DUKUNG LATERAL FONDASI TIANG TUNGGAL DENGAN PEMBEBANAN STATIK DAN SIKLIK
ANALISIS PENGARUH DIAMETER TIANG TERHADAP DAYA DUKUNG LATERAL FONDASI TIANG TUNGGAL DENGAN PEMBEBANAN STATIK DAN SIKLIK
The pile foundation is a frequently chosen option in constructing multi-story buildings, where the vertical load is substantial and needs to be transferred to hard soil/strata. Mul...
PENGARUH DIAMETER TIANG TERHADAP TAHANAN GESEK TIANG DALAM TANAH LEMPUNG
PENGARUH DIAMETER TIANG TERHADAP TAHANAN GESEK TIANG DALAM TANAH LEMPUNG
AbstractSome buildings impose limits on the foundation displacement that occur with relatively small values so as not to cause structural damage. The test method used was to make a...
PERENCANAAN FONDASI TIANG PANCANG PADA PROYEK TOWER 2 ARANDRA RESIDENCE
PERENCANAAN FONDASI TIANG PANCANG PADA PROYEK TOWER 2 ARANDRA RESIDENCE
ABSTRACTThe pile foundation is an sub-structure to load from the upper structure. Ultimate load carrying-capacity (qu) will be transfered into a hard soil layer by using a deep fou...
UJI TAHANAN TARIK MODEL FONDASI TIANG DALAM TANAH PASIR
UJI TAHANAN TARIK MODEL FONDASI TIANG DALAM TANAH PASIR
ABSTRACTCertain buildings limit displacement of pile foundation with relatively small value so as not to cause damage to the structure. Loading test directly in the field requires ...
ANALISIS JENIS PONDASI PADA GEDUNG REKTORAT AKPER SUMBAWA KABUPATEN SUMBAWA
ANALISIS JENIS PONDASI PADA GEDUNG REKTORAT AKPER SUMBAWA KABUPATEN SUMBAWA
Akademi Keperawatan (AKPER) Sumbawa merupakan salah satu universitas yang saat ini dalam proses pembangunan dengan perencanaan 3 lantai dan 1 lantai sebagai basement dengan rencana...