Javascript must be enabled to continue!
Efficiency and safety of his bundle pacing in patients with newly-acquired heart failure after long-term right ventricular pacing, results from China mainland
View through CrossRef
Abstract
Background
Clinical outcomes of his bundle pacing (HBP) lead implantation in patients with pacing induced cardiomyopathy (PICM) are unknown. We aim to investigate the efficiency and safety of HBP upgrade in a single center.
Methods and results
Patients with PICM and indication of resynchronization therapy were selected during 2018.1–2019.12. Clinical data including parameters of echocardiographic examination, ECG measurements, New York Heart Association (NYHA) classification were assessed before and after HBP upgrade. HBP upgrade was fulfilled in 38 of 40 (95%) patients. During a mean of 9.36±5.63 months follow-up, 28 patients completed the follow-up of clinical data. The mean age was 67.86±12.85 years and men account for 67.9%. Mean of H-V interval was 56.86±7.11ms. Left ventricular ejection fraction (LVEF) significantly increased from baseline 32.75% to 44.19% (P<0.01). QRS duration decreased from 184.67±27.35 ms at baseline to 123.28±15.82ms with HBP (P<0.01). LVEDD remodeled reversed from 60.85 mm at right ventricular pacing (RVP) implantation to 53.16mm. NYHA functional class improved to 1.96 from 2.64 at baseline during follow-up (P<0.01). Over a median follow-up period of 3.03 (0.9–19.4) months, threshold of his bundle lead decreased from baseline 1.35±0.89mv to 1.2±0.89mv but no significance (P=0.308>0.05).
Conclusion
HBP significantly improved echocardiographic measurements and NYHA classification for those with PICM. The threshold of his bundle lead is relatively stable in our follow-up period, reminding that the HBP upgrade is safe and effective for PICM patients.
Funding Acknowledgement
Type of funding source: Public hospital(s). Main funding source(s): This study was supported by grants from Liaoning Clinical Capacity Construction Funding (LNCCC-D-20-2015).
Oxford University Press (OUP)
Title: Efficiency and safety of his bundle pacing in patients with newly-acquired heart failure after long-term right ventricular pacing, results from China mainland
Description:
Abstract
Background
Clinical outcomes of his bundle pacing (HBP) lead implantation in patients with pacing induced cardiomyopathy (PICM) are unknown.
We aim to investigate the efficiency and safety of HBP upgrade in a single center.
Methods and results
Patients with PICM and indication of resynchronization therapy were selected during 2018.
1–2019.
12.
Clinical data including parameters of echocardiographic examination, ECG measurements, New York Heart Association (NYHA) classification were assessed before and after HBP upgrade.
HBP upgrade was fulfilled in 38 of 40 (95%) patients.
During a mean of 9.
36±5.
63 months follow-up, 28 patients completed the follow-up of clinical data.
The mean age was 67.
86±12.
85 years and men account for 67.
9%.
Mean of H-V interval was 56.
86±7.
11ms.
Left ventricular ejection fraction (LVEF) significantly increased from baseline 32.
75% to 44.
19% (P<0.
01).
QRS duration decreased from 184.
67±27.
35 ms at baseline to 123.
28±15.
82ms with HBP (P<0.
01).
LVEDD remodeled reversed from 60.
85 mm at right ventricular pacing (RVP) implantation to 53.
16mm.
NYHA functional class improved to 1.
96 from 2.
64 at baseline during follow-up (P<0.
01).
Over a median follow-up period of 3.
03 (0.
9–19.
4) months, threshold of his bundle lead decreased from baseline 1.
35±0.
89mv to 1.
2±0.
89mv but no significance (P=0.
308>0.
05).
Conclusion
HBP significantly improved echocardiographic measurements and NYHA classification for those with PICM.
The threshold of his bundle lead is relatively stable in our follow-up period, reminding that the HBP upgrade is safe and effective for PICM patients.
Funding Acknowledgement
Type of funding source: Public hospital(s).
Main funding source(s): This study was supported by grants from Liaoning Clinical Capacity Construction Funding (LNCCC-D-20-2015).
Related Results
Evolution of Antimicrobial Resistance in Community vs. Hospital-Acquired Infections
Evolution of Antimicrobial Resistance in Community vs. Hospital-Acquired Infections
Abstract
Introduction
Hospitals are high-risk environments for infections. Despite the global recognition of these pathogens, few studies compare microorganisms from community-acqu...
Long‐Term Follow‐up Impact of Dual‐Chamber Pacing on Patients with Hypertrophic Obstructive Cardiomyopathy
Long‐Term Follow‐up Impact of Dual‐Chamber Pacing on Patients with Hypertrophic Obstructive Cardiomyopathy
BackgroundPacing has been proposed as a treatment for patients with hypertrophic obstructive cardiomyopathy (HOCM), but there are few studies with long‐term follow‐up. We evaluated...
Acute Changes in Cardiac Synchrony and Output According to RV Pacing Sites in Koreans with Normal Cardiac Function
Acute Changes in Cardiac Synchrony and Output According to RV Pacing Sites in Koreans with Normal Cardiac Function
Introduction: The synchrony of the pacing heart can be affected by the right ventricular (RV) pacing site and is crucial to cardiac function in pacemaker recipients. We evaluated t...
Increased QRS duration and dispersion are associated with mechanical dyssynchrony in patients with permanent right ventricular apical pacing
Increased QRS duration and dispersion are associated with mechanical dyssynchrony in patients with permanent right ventricular apical pacing
Background: Permanent right ventricular apical pacing may have negative effects on ventricular function and contribute to development of heart failure. We aimed to assess intra- an...
Small Cell Lung Cancer and Tarlatamab: A Meta-Analysis of Clinical Trials
Small Cell Lung Cancer and Tarlatamab: A Meta-Analysis of Clinical Trials
Abstract
Introduction
Tarlatamab is a Delta-like ligand 3 (DLL3) -directed bispecific T-cell engager recently approved for use in patients with advanced small cell lung cancer (SCL...
Comparison of Clinical Complications Between LBBAP and Traditional RVP in Long-Term Follow-Up
Comparison of Clinical Complications Between LBBAP and Traditional RVP in Long-Term Follow-Up
Background. Traditional right ventricular pacing (RVP) can lead to asynchronous cardiac mechanical contractions and increase the risk of adverse cardiac events. This study aimed to...
Changes in pacing variation with increasing race duration in ultra-triathlon races
Changes in pacing variation with increasing race duration in ultra-triathlon races
Abstract
Background: Despite the increasing scientific interest in the relationship between pacing and performance in endurance sports, little information is available abou...
Heart failure monitoring using the wearable cardioverter defibrillator in patients with newly diagnosed heart failure
Heart failure monitoring using the wearable cardioverter defibrillator in patients with newly diagnosed heart failure
Abstract
Funding Acknowledgements
Type of funding sources: None.
Background
...

