Javascript must be enabled to continue!
Increased QRS duration and dispersion are associated with mechanical dyssynchrony in patients with permanent right ventricular apical pacing
View through CrossRef
Background: Permanent right ventricular apical pacing may have negative effects on ventricular function and contribute to development of heart failure. We aimed to assess intra- and interventricular mechanical dyssynchrony in patients with permanent right ventricular apical pacing, and to establish electrocardiographic markers of dyssynchrony. Methods: 84 patients (46:38 male:female) who required permanent pacing were studied. Pacing was done from right ventricular apex in all patients. We measured QRS duration and dispersion on standard 12-lead ECG. Intra- and interventricular mechanical dyssynchrony and left ventricular ejection fraction were assessed by transthoracic echocardiography. Patients were followed-up for 24 months. Results: Six months after implantation, QRS duration increased from 128.02 ms to 132.40 ms, p≤0.05. At 24 months, QRS dispersion increased from 43.26 ms to 46.13 ms, p≤0.05. Intra- and interventricular dyssynchrony increased and left ventricular ejection fraction decreased during follow-up. A QRS dispersion of 47 ms predicted left ventricular dysfunction and long-term electromechanical dyssynchrony with a sensitivity of 80% and a specificity of 76%. Conclusion: In patients with permanent right ventricular apical pacing there is an increased duration and dispersion of QRS related to dyssynchrony and decreased left ventricular ejection fraction. This study shows that QRS dispersion could be a better predictive variable than QRS duration for identifying left ventricular ejection fraction worsening in patients with permanent right ventricular apical pacing. The electrocardiogram is a simple tool for predicting systolic function worsening in these patients and can be used at the bedside for early diagnosis in the absence of clinical symptoms, allowing adjustments of medical treatment to prevent progression of heart failure and improve the patient's quality of life.
Title: Increased QRS duration and dispersion are associated with mechanical dyssynchrony in patients with permanent right ventricular apical pacing
Description:
Background: Permanent right ventricular apical pacing may have negative effects on ventricular function and contribute to development of heart failure.
We aimed to assess intra- and interventricular mechanical dyssynchrony in patients with permanent right ventricular apical pacing, and to establish electrocardiographic markers of dyssynchrony.
Methods: 84 patients (46:38 male:female) who required permanent pacing were studied.
Pacing was done from right ventricular apex in all patients.
We measured QRS duration and dispersion on standard 12-lead ECG.
Intra- and interventricular mechanical dyssynchrony and left ventricular ejection fraction were assessed by transthoracic echocardiography.
Patients were followed-up for 24 months.
Results: Six months after implantation, QRS duration increased from 128.
02 ms to 132.
40 ms, p≤0.
05.
At 24 months, QRS dispersion increased from 43.
26 ms to 46.
13 ms, p≤0.
05.
Intra- and interventricular dyssynchrony increased and left ventricular ejection fraction decreased during follow-up.
A QRS dispersion of 47 ms predicted left ventricular dysfunction and long-term electromechanical dyssynchrony with a sensitivity of 80% and a specificity of 76%.
Conclusion: In patients with permanent right ventricular apical pacing there is an increased duration and dispersion of QRS related to dyssynchrony and decreased left ventricular ejection fraction.
This study shows that QRS dispersion could be a better predictive variable than QRS duration for identifying left ventricular ejection fraction worsening in patients with permanent right ventricular apical pacing.
The electrocardiogram is a simple tool for predicting systolic function worsening in these patients and can be used at the bedside for early diagnosis in the absence of clinical symptoms, allowing adjustments of medical treatment to prevent progression of heart failure and improve the patient's quality of life.
Related Results
Time interval from left ventricular stimulation to QRS onset is a predictor of mortality in patients with cardiac resynchronization therapy
Time interval from left ventricular stimulation to QRS onset is a predictor of mortality in patients with cardiac resynchronization therapy
Abstract
Introduction
In our previous report, the time interval from left ventricular (LV) pacing to the earliest onset of QRS (...
GW24-e2922 The clinical correlates and prognostic impact of QRS prolongation in patients with dilated cardiomyopathy
GW24-e2922 The clinical correlates and prognostic impact of QRS prolongation in patients with dilated cardiomyopathy
Objectives
Prolongation of the QRS duration (≥ 120 ms) has been suggested to be an independent risk factor for mortality in patients with heart failure. The purpo...
Acute Changes in Cardiac Synchrony and Output According to RV Pacing Sites in Koreans with Normal Cardiac Function
Acute Changes in Cardiac Synchrony and Output According to RV Pacing Sites in Koreans with Normal Cardiac Function
Introduction: The synchrony of the pacing heart can be affected by the right ventricular (RV) pacing site and is crucial to cardiac function in pacemaker recipients. We evaluated t...
e0650 The effects of biventricular synchronous pacing on CBF, MVO2 and CWE in dogs
e0650 The effects of biventricular synchronous pacing on CBF, MVO2 and CWE in dogs
Objective
To compare the effects of biventricular synchronous pacing with different pacing site on coronary Blood flow (CBF), myocardial oxygen consumption (MVO2)...
Emerging Evidence of IgG4-Related Disease in Pericarditis: A Systematic Review
Emerging Evidence of IgG4-Related Disease in Pericarditis: A Systematic Review
Abstract
Introduction
Immunoglobulin G4-related disease (IgG4-RD) is a recently identified immune-mediated condition that is debilitating and often overlooked. While IgG4-RD has be...
Left bundle branch area pacing: Electrocardiographic features
Left bundle branch area pacing: Electrocardiographic features
Background Left bundle branch (LBB) area pacing emerged as a promising
alternative to His bundle (HB) pacing in difficult cases of
physiological pacing and failed cases of cardiac ...
Correlation Study on Left Ventricular Mechanical and Electrical Dyssynchrony in Patients with Chronic Heart Failure
Correlation Study on Left Ventricular Mechanical and Electrical Dyssynchrony in Patients with Chronic Heart Failure
Abstract
Objective
This study aimed to investigate the correlation between left ventricular (LV) mechanical and electrical dyssynchrony in patients with chronic hea...
Prevalence of Electromechanical Dyssynchrony among Heart Failure Patients in a Nigerian Tertiary Hospital
Prevalence of Electromechanical Dyssynchrony among Heart Failure Patients in a Nigerian Tertiary Hospital
Context:
Heart failure (HF) is among the most important causes of morbidity and mortality worldwide. Cardiac dyssynchrony, a situation associated with a difference in t...

