Javascript must be enabled to continue!
Enhancing heart disease diagnosis through precise heart sound including infrasound
View through CrossRef
Recent research has been pushing the frontier of diagnosing cardiovascular diseases, which have a high mortality rate globally. The need for swift responses to acute diseases has underscored the importance of continuous health monitoring and the development of monitoring diagnostic technology. Our work focused on an overlooked aspect—the microphones used to measure heart sounds. Existing ones, particularly capacitive MEMS types, measure only heart sounds primarily within the audible frequency range, potentially limiting the diagnostic accuracy. To overcome these limitations, we used microphones capable of measuring down to infrasound areas. We also designed an experimental environment to capture the precise heart sounds. The crux of our approach was using the full information of heart sounds through infrasound measurements. A convolutional neural network-based deep learning model was employed for algorithm development and validated using the PhysioNet 2016 CinC’s open-source heart sound data. We conducted an experiment on the impact of low-frequency components on heart sound diagnosis using a new infrasound dataset measured at Seoul St. Mary's Hospital of the Catholic University of Korea. Accuracy and sensitivity, respectively, improved on average by 2% and 4%, showing that datasets including low-frequency components generally performed better.
Acoustical Society of America (ASA)
Title: Enhancing heart disease diagnosis through precise heart sound including infrasound
Description:
Recent research has been pushing the frontier of diagnosing cardiovascular diseases, which have a high mortality rate globally.
The need for swift responses to acute diseases has underscored the importance of continuous health monitoring and the development of monitoring diagnostic technology.
Our work focused on an overlooked aspect—the microphones used to measure heart sounds.
Existing ones, particularly capacitive MEMS types, measure only heart sounds primarily within the audible frequency range, potentially limiting the diagnostic accuracy.
To overcome these limitations, we used microphones capable of measuring down to infrasound areas.
We also designed an experimental environment to capture the precise heart sounds.
The crux of our approach was using the full information of heart sounds through infrasound measurements.
A convolutional neural network-based deep learning model was employed for algorithm development and validated using the PhysioNet 2016 CinC’s open-source heart sound data.
We conducted an experiment on the impact of low-frequency components on heart sound diagnosis using a new infrasound dataset measured at Seoul St.
Mary's Hospital of the Catholic University of Korea.
Accuracy and sensitivity, respectively, improved on average by 2% and 4%, showing that datasets including low-frequency components generally performed better.
Related Results
Wind induced infrasound in the atmosphere
Wind induced infrasound in the atmosphere
Characteristics of atmosphere infrasound noise field have been studied by measuring and analyzing the infrasound noise field in the atmosphere. A set of space correlation radii of ...
Acoustic far-field prediction based on near-field measurements by using several different holography algorithms
Acoustic far-field prediction based on near-field measurements by using several different holography algorithms
Near-field acoustical holography (NAH) is a useful tool for sound field reconstruction and sound source identification. In NAH, a basis model is first selected to represent the phy...
[RETRACTED] Prima Weight Loss Dragons Den UK v1
[RETRACTED] Prima Weight Loss Dragons Den UK v1
[RETRACTED]Prima Weight Loss Dragons Den UK :-Obesity is a not kidding medical issue brought about by devouring an excessive amount of fat, eating terrible food sources, and practi...
[RETRACTED] Prima Weight Loss Dragons Den UK v1
[RETRACTED] Prima Weight Loss Dragons Den UK v1
[RETRACTED]Prima Weight Loss Dragons Den UK :-Obesity is a not kidding medical issue brought about by devouring an excessive amount of fat, eating terrible food sources, and practi...
On the Noise-Enhancing Ability of Stochastic Hodgkin-Huxley Neuron Systems
On the Noise-Enhancing Ability of Stochastic Hodgkin-Huxley Neuron Systems
Recently noise has been shown to be useful in enhancing neuron sensitivity by stochastic resonance. In this study, in order to measure the noise-enhancing factor (NEF), a nonlinear...
Investigating Sound in Space: Five meanings of space in music and sound art
Investigating Sound in Space: Five meanings of space in music and sound art
Since the 1950s the spatiality of sound has become a key concept in different fields of artistic practice, emerging as one of the most relevant subjects in the contemporary arts. I...
Partipatory disease surveilance in Fentale & Adama Districts of East Shewa Zone, Oromia Regional State
Partipatory disease surveilance in Fentale & Adama Districts of East Shewa Zone, Oromia Regional State
Livestock play a major role in the livelihoods of over 70% of the population. Small ruminants provide with a vast range of products and services, including milk, meat, skins, and w...
Presence of Crystals in the Synovial Fluid of Patients With Psoriatic Arthritis
Presence of Crystals in the Synovial Fluid of Patients With Psoriatic Arthritis
Analyzing synovial fluid from joints affected by the pathological process of psoriatic arthritis is part of the overall patient examination, since it may have differential diagnost...