Javascript must be enabled to continue!
Topaz-Denoise: general deep denoising models for cryoEM and cryoET
View through CrossRef
AbstractCryo-electron microscopy (cryoEM) is becoming the preferred method for resolving protein structures. Low signal-to-noise (SNR) in cryoEM images reduces the confidence and throughput of structure determination during several steps of data processing, resulting in impediments such as missing particle orientations. Denoising cryoEM images can not only improve downstream analysis but also accelerate the time-consuming data collection process by allowing lower electron dose micrographs to be used for analysis. Here, we present Topaz-Denoise, a deep learning method for reliably and rapidly increasing the SNR of cryoEM images and cryoET tomograms. By training on a dataset composed of thousands of micrographs collected across a wide range of imaging conditions, we are able to learn models capturing the complexity of the cryoEM image formation process. The general model we present is able to denoise new datasets without additional training. Denoising with this model improves micrograph interpretability, enabling us to solve the first 3D single particle closed and partially open structures of clustered protocadherin, an elongated particle with previously-elusive views. We then show for the first time that low dose collection, enabled by Topaz-Denoise, improves downstream analysis in addition to reducing data collection time. We also present the first general 3D denoising model for cryoET. Topaz-Denoise and pre-trained general models are now included in Topaz. We expect that Topaz-Denoise will be of broad utility to the cryoEM community for improving micrograph and tomogram interpretability and accelerating analysis.
Title: Topaz-Denoise: general deep denoising models for cryoEM and cryoET
Description:
AbstractCryo-electron microscopy (cryoEM) is becoming the preferred method for resolving protein structures.
Low signal-to-noise (SNR) in cryoEM images reduces the confidence and throughput of structure determination during several steps of data processing, resulting in impediments such as missing particle orientations.
Denoising cryoEM images can not only improve downstream analysis but also accelerate the time-consuming data collection process by allowing lower electron dose micrographs to be used for analysis.
Here, we present Topaz-Denoise, a deep learning method for reliably and rapidly increasing the SNR of cryoEM images and cryoET tomograms.
By training on a dataset composed of thousands of micrographs collected across a wide range of imaging conditions, we are able to learn models capturing the complexity of the cryoEM image formation process.
The general model we present is able to denoise new datasets without additional training.
Denoising with this model improves micrograph interpretability, enabling us to solve the first 3D single particle closed and partially open structures of clustered protocadherin, an elongated particle with previously-elusive views.
We then show for the first time that low dose collection, enabled by Topaz-Denoise, improves downstream analysis in addition to reducing data collection time.
We also present the first general 3D denoising model for cryoET.
Topaz-Denoise and pre-trained general models are now included in Topaz.
We expect that Topaz-Denoise will be of broad utility to the cryoEM community for improving micrograph and tomogram interpretability and accelerating analysis.
Related Results
Theoretical framework and experimental solution for the air-water interface adsorption problem in cryoEM
Theoretical framework and experimental solution for the air-water interface adsorption problem in cryoEM
AbstractAs cryogenic electron microscopy (cryoEM) gains traction in the structural biology community as a method of choice for determining atomic structures of biological complexes...
Enhancing bone scan image quality: an improved self-supervised denoising approach
Enhancing bone scan image quality: an improved self-supervised denoising approach
Abstract
Objective. Bone scans play an important role in skeletal lesion assessment, but gamma cameras exhibit challenges with low sensitivity and...
Combining denoising of RNA-seq data and flux balance analysis for cluster analysis of single cells
Combining denoising of RNA-seq data and flux balance analysis for cluster analysis of single cells
Abstract
Background
Sophisticated methods to properly pre-process and analyze the increasing collection of single-cell RNA sequencing (scRNA-seq) da...
Wavelet Denoising of Well Logs and its Geological Performance
Wavelet Denoising of Well Logs and its Geological Performance
Well logs play a very important role in exploration and even exploitation of energy resources, but they usually contain kinds of noises which affect the results of the geological i...
Topaz-bearing Lower Ordovician orthogneiss within the Ostrong Nappe System – The Laimbach Orthogneiss (Bohemian Massif, Lower Austria)
Topaz-bearing Lower Ordovician orthogneiss within the Ostrong Nappe System – The Laimbach Orthogneiss (Bohemian Massif, Lower Austria)
Abstract
In the 1980s, large parts of the Bohemian Massif in Austria were explored for the occurrence of raw materials (Göd, 1988), and a trace content of topaz was ...
Complex Deep Learning Models for Denoising of Human Heart ECG signals
Complex Deep Learning Models for Denoising of Human Heart ECG signals
Effective and powerful methods for denoising real electrocardiogram (ECG) signals are important for wearable sensors and devices. Deep Learning (DL) models have been used extensive...
Denoising method of microwave earth exploration test system based on Deep-KSVD
Denoising method of microwave earth exploration test system based on Deep-KSVD
Abstract
In the process of data acquisition of complex underground media in the microwave ground exploration test system, electromagnetic echoes are susceptible to v...
Remote sensing image denoising based on shearlet transform and goodness-of-fit test
Remote sensing image denoising based on shearlet transform and goodness-of-fit test
Aiming at Gaussian white noise in remote sensing images, a remote sensing image denoising algorithm based on shearlet transform and goodness of fit test is proposed. Firstly, the n...